Seiichi Yamaguchi

准教授(任期付)

  • 308 Citations
  • 8 h-Index
20102019
If you made any changes in Pure these will be visible here soon.

Research Output 2010 2019

  • 308 Citations
  • 8 h-Index
  • 24 Article
  • 9 Conference contribution
  • 1 Paper
Filter
Article
2019
1 Citation (Scopus)

Analyse numérique des caractéristiques de régulation des systèmes de pompe à chaleur à débit de frigorigène variable en se concentrant sur l'effet du détendeur et du ventilateur intérieur

Translated title of the contribution: Numerical analysis of control characteristics of variable refrigerant flow heat-pump systems focusing on the effect of expansion valve and indoor fanMatsumoto, K., Ohno, K., Yamaguchi, S. & Saito, K., 2019 Mar 1, In : International Journal of Refrigeration. 99, p. 440-452 13 p.

Research output: Contribution to journalArticle

Plant expansion
Heat pump systems
Fans
Numerical analysis
Flow of fluids
Microchannels
Air conditioning
Two phase flow
Heat exchangers
Liquids
Air conditioning
Exergy
Thermodynamics
Neural networks
Thermal comfort
2018
5 Citations (Scopus)

Annular flow stability within small-sized channels

Giannetti, N., Kunita, D., Yamaguchi, S. & Saito, K., 2018 Jan 1, In : International Journal of Heat and Mass Transfer. 116, p. 1153-1162 10 p.

Research output: Contribution to journalArticle

annular flow
flow stability
Surface tension
interfacial tension
Void fraction
1 Citation (Scopus)
Wetting
Differential equations
Temperature
3 Citations (Scopus)

Étude expérimentale des caractéristiques de mouillage d'une solution aqueuse de liquide ionique sur un substrat à tube à ailettes en aluminium

Translated title of the contribution: Experimental investigation of the wetting characteristics of an aqueous ionic liquid solution on an aluminum fin-tube substrateVarela, R. J., Giannetti, N., Yamaguchi, S., Saito, K., Wang, X. M. & Nakayama, H., 2018 Apr 1, In : International Journal of Refrigeration. 88, p. 472-482 11 p.

Research output: Contribution to journalArticle

Ionic liquids
Wetting
Aluminum
Substrates
Contact angle

Expressions simplifiées des coefficients de transfert sur un tube absorbeur partiellement humide

Translated title of the contribution: Simplified expressions of the transfer coefficients on a partially wet absorber tubeGiannetti, N., Yamaguchi, S. & Saito, K., 2018 Jan 1, (Accepted/In press) In : International Journal of Refrigeration.

Research output: Contribution to journalArticle

Heat transfer coefficients
Wetting
Differential equations
Mass transfer
Temperature
5 Citations (Scopus)
Hygroscopic Agents
desiccants
contactors
Heat transfer coefficients
mass transfer
7 Citations (Scopus)
falling
Heat transfer coefficients
mass transfer
Mass transfer
heat transfer
5 Citations (Scopus)

Operation performance enhancement of single-double-effect absorption chiller

Arnas, A., Jeong, J., Giannetti, N., Yamaguchi, S., Saito, K., Yabase, H., Alhamid, M. I. & Nasruddin, 2018 Jun 1, In : Applied Energy. 219, p. 299-311 13 p.

Research output: Contribution to journalArticle

Solar energy
Cooling
Refrigeration
Solar radiation
Air conditioning
1 Citation (Scopus)
Ionic liquids
Wetting
Aluminum
Flow rate
2 Citations (Scopus)

Simulation numérique de la convection de Marangoni dans du Li-Br aqueux absorbant

Translated title of the contribution: Numerical simulation of Marangoni convection within absorptive aqueous Li-BrGiannetti, N., Yamaguchi, S. & Saito, K., 2018 Aug 1, In : International Journal of Refrigeration. 92, p. 176-184 9 p.

Research output: Contribution to journalArticle

Surface tension
Computer simulation
Free energy
Shear stress
Numerical models

Thermodynamic analysis of irreversible desiccant systems

Giannetti, N., Yamaguchi, S., Rocchetti, A. & Saito, K., 2018 Aug 1, In : Entropy. 20, 8, 595.

Research output: Contribution to journalArticle

desiccants
thermodynamics
dehumidification
air conditioning
working fluids
2017
8 Citations (Scopus)

Analytical solution of film mass-transfer on a partially wetted absorber tube

Giannetti, N., Rocchetti, A., Yamaguchi, S. & Saito, K., 2017 Aug 1, In : International Journal of Thermal Sciences. 118, p. 176-186 11 p.

Research output: Contribution to journalArticle

mass transfer
absorbers
Mass transfer
tubes
falling
9 Citations (Scopus)

Experimental performance of a double-lift absorption heat transformer for manufacturing-process steam generation

Arnas, A., Giannetti, N., Yamaguchi, S., Saito, K. & Inoue, N., 2017 Sep 15, In : Energy Conversion and Management. 148, p. 267-278 12 p.

Research output: Contribution to journalArticle

Steam
Temperature
Waste heat
Refrigerants
Waste heat utilization
2016
10 Citations (Scopus)

Entropy parameters for falling film absorber optimization

Giannetti, N., Rocchetti, A., Arnas, A., Saito, K. & Yamaguchi, S., 2016 Jan 25, In : Applied Thermal Engineering. 93, p. 750-762 13 p.

Research output: Contribution to journalArticle

Entropy
Flow rate
Thermodynamics
Cooling
Refrigerators
11 Citations (Scopus)
Hygroscopic Agents
desiccants
contactors
Liquid films
wetting
2015
8 Citations (Scopus)

Entropy parameters for desiccant wheel design

Giannetti, N., Rocchetti, A., Saito, K. & Yamaguchi, S., 2015 Jan 22, In : Applied Thermal Engineering. 75, p. 826-838 13 p.

Research output: Contribution to journalArticle

Wheels
Entropy
Heat exchangers
Ion exchange
Mass transfer
6 Citations (Scopus)

Irreversibility analysis of falling film absorption over a cooled horizontal tube

Giannetti, N., Rocchetti, A., Saito, K. & Yamaguchi, S., 2015 Sep 1, In : International Journal of Heat and Mass Transfer. 88, p. 755-765 11 p.

Research output: Contribution to journalArticle

falling
tubes
mass flow rate
Flow rate
Steam
2013
47 Citations (Scopus)
Hygroscopic Agents
desiccants
wheels
Wheels
air conditioning
2011
24 Citations (Scopus)

Development and validation of static simulation model for CO2 heat pump

Yamaguchi, S., Kato, D., Saito, K. & Kawai, S., 2011 Apr, In : International Journal of Heat and Mass Transfer. 54, 9-10, p. 1896-1906 11 p.

Research output: Contribution to journalArticle

heat pumps
Water heaters
Pumps
water temperature
Water
55 Citations (Scopus)

Hybrid liquid desiccant air-conditioning system: Experiments and simulations

Yamaguchi, S., Jeong, J., Saito, K., Miyauchi, H. & Harada, M., 2011 Dec, In : Applied Thermal Engineering. 31, 17-18, p. 3741-3747 7 p.

Research output: Contribution to journalArticle

Air conditioning
Liquids
Experiments
Vapors
Pumps
34 Citations (Scopus)

Performance analysis of desiccant dehumidification systems driven by low-grade heat source

Jeong, J., Yamaguchi, S., Saito, K. & Kawai, S., 2011 Jun, In : International Journal of Refrigeration. 34, 4, p. 928-945 18 p.

Research output: Contribution to journalArticle

Wheels
Waste heat
Air
Temperature
Heat exchangers
2010
61 Citations (Scopus)

Performance analysis of four-partition desiccant wheel and hybrid dehumidification air-conditioning system

Jeong, J., Yamaguchi, S., Saito, K. & Kawai, S., 2010 May, In : International Journal of Refrigeration. 33, 3, p. 496-509 14 p.

Research output: Contribution to journalArticle

Partitions (building)
Air conditioning
Wheels
Energy conservation
Refrigerators