    Many single phase distributed generators (DGs) - such as solar cells, small scale gas-engine CHP systems, etc. - are being installed in an electric power distribution system in recent years. These distributed generators are not always generating steady power due to the weather conditions or hot-water demand conditions, etc. Therefore, DGs could make "balanced threephase load" unbalanced. Unexpected load unbalance creates many unpredicted problems in power distribution systems: voltage unbalances, frequency deviations, etc. It is also known that the loss minimum normal open sectionalizing switch positions for three phase unbalanced conditions are not the same as the ones calculated by assuming three-phase balanced. Therefore, a method to find the optimal normal open sectionalizing switch positions that minimize both distribution loss and three phase unbalance is required. The problem is the multi-objective planning problem, and the palate solution must be found. In this paper, a solution algorithm for loss minimum re-configuration is explained and several numerical examples are shown.

    Original languageEnglish
    Title of host publicationIEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES
    DOIs
    Publication statusPublished - 2008
    EventIEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES - Pittsburgh, PA
    Duration: 2008 Jul 202008 Jul 24

    Other

    OtherIEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES
    CityPittsburgh, PA
    Period08/7/2008/7/24

    Fingerprint

    Switches
    Gas engines
    Electric power distribution
    Solar cells
    Planning
    Electric potential
    Water

    Keywords

    • Distributed generator
    • Distribution system
    • Load transfer
    • Loss minimization
    • Re-configuration
    • Three-phase unbalance

    ASJC Scopus subject areas

    • Energy Engineering and Power Technology
    • Electrical and Electronic Engineering

    Cite this

    Tanabe, T., Funabashi, T., Nara, K., Mishima, Y., & Yokoyama, R. (2008). A loss minimum re-configuration algorithm of distribution systems under three-phase unbalanced condition. In IEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES [4596121] https://doi.org/10.1109/PES.2008.4596121

    A loss minimum re-configuration algorithm of distribution systems under three-phase unbalanced condition. / Tanabe, T.; Funabashi, T.; Nara, K.; Mishima, Y.; Yokoyama, R.

    IEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES. 2008. 4596121.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Tanabe, T, Funabashi, T, Nara, K, Mishima, Y & Yokoyama, R 2008, A loss minimum re-configuration algorithm of distribution systems under three-phase unbalanced condition. in IEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES., 4596121, IEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES, Pittsburgh, PA, 08/7/20. https://doi.org/10.1109/PES.2008.4596121
    Tanabe T, Funabashi T, Nara K, Mishima Y, Yokoyama R. A loss minimum re-configuration algorithm of distribution systems under three-phase unbalanced condition. In IEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES. 2008. 4596121 https://doi.org/10.1109/PES.2008.4596121
    Tanabe, T. ; Funabashi, T. ; Nara, K. ; Mishima, Y. ; Yokoyama, R. / A loss minimum re-configuration algorithm of distribution systems under three-phase unbalanced condition. IEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES. 2008.
    @inproceedings{a6801c14c28a46baa198b16c48e68aa4,
    title = "A loss minimum re-configuration algorithm of distribution systems under three-phase unbalanced condition",
    abstract = "Many single phase distributed generators (DGs) - such as solar cells, small scale gas-engine CHP systems, etc. - are being installed in an electric power distribution system in recent years. These distributed generators are not always generating steady power due to the weather conditions or hot-water demand conditions, etc. Therefore, DGs could make {"}balanced threephase load{"} unbalanced. Unexpected load unbalance creates many unpredicted problems in power distribution systems: voltage unbalances, frequency deviations, etc. It is also known that the loss minimum normal open sectionalizing switch positions for three phase unbalanced conditions are not the same as the ones calculated by assuming three-phase balanced. Therefore, a method to find the optimal normal open sectionalizing switch positions that minimize both distribution loss and three phase unbalance is required. The problem is the multi-objective planning problem, and the palate solution must be found. In this paper, a solution algorithm for loss minimum re-configuration is explained and several numerical examples are shown.",
    keywords = "Distributed generator, Distribution system, Load transfer, Loss minimization, Re-configuration, Three-phase unbalance",
    author = "T. Tanabe and T. Funabashi and K. Nara and Y. Mishima and R. Yokoyama",
    year = "2008",
    doi = "10.1109/PES.2008.4596121",
    language = "English",
    isbn = "9781424419067",
    booktitle = "IEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES",

    }

    TY - GEN

    T1 - A loss minimum re-configuration algorithm of distribution systems under three-phase unbalanced condition

    AU - Tanabe, T.

    AU - Funabashi, T.

    AU - Nara, K.

    AU - Mishima, Y.

    AU - Yokoyama, R.

    PY - 2008

    Y1 - 2008

    N2 - Many single phase distributed generators (DGs) - such as solar cells, small scale gas-engine CHP systems, etc. - are being installed in an electric power distribution system in recent years. These distributed generators are not always generating steady power due to the weather conditions or hot-water demand conditions, etc. Therefore, DGs could make "balanced threephase load" unbalanced. Unexpected load unbalance creates many unpredicted problems in power distribution systems: voltage unbalances, frequency deviations, etc. It is also known that the loss minimum normal open sectionalizing switch positions for three phase unbalanced conditions are not the same as the ones calculated by assuming three-phase balanced. Therefore, a method to find the optimal normal open sectionalizing switch positions that minimize both distribution loss and three phase unbalance is required. The problem is the multi-objective planning problem, and the palate solution must be found. In this paper, a solution algorithm for loss minimum re-configuration is explained and several numerical examples are shown.

    AB - Many single phase distributed generators (DGs) - such as solar cells, small scale gas-engine CHP systems, etc. - are being installed in an electric power distribution system in recent years. These distributed generators are not always generating steady power due to the weather conditions or hot-water demand conditions, etc. Therefore, DGs could make "balanced threephase load" unbalanced. Unexpected load unbalance creates many unpredicted problems in power distribution systems: voltage unbalances, frequency deviations, etc. It is also known that the loss minimum normal open sectionalizing switch positions for three phase unbalanced conditions are not the same as the ones calculated by assuming three-phase balanced. Therefore, a method to find the optimal normal open sectionalizing switch positions that minimize both distribution loss and three phase unbalance is required. The problem is the multi-objective planning problem, and the palate solution must be found. In this paper, a solution algorithm for loss minimum re-configuration is explained and several numerical examples are shown.

    KW - Distributed generator

    KW - Distribution system

    KW - Load transfer

    KW - Loss minimization

    KW - Re-configuration

    KW - Three-phase unbalance

    UR - http://www.scopus.com/inward/record.url?scp=52349113807&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=52349113807&partnerID=8YFLogxK

    U2 - 10.1109/PES.2008.4596121

    DO - 10.1109/PES.2008.4596121

    M3 - Conference contribution

    SN - 9781424419067

    BT - IEEE Power and Energy Society 2008 General Meeting: Conversion and Delivery of Electrical Energy in the 21st Century, PES

    ER -