A scintillation response and an ionization yield in pure xenon and mixtures of it with methane

K. N. Pushkin, Nobuyuki Hasebe, C. Tezuka, S. Kobayashi, M. Mimura, T. Hosojima, T. Doke, M. Miyajima, T. Miyachi, E. Shibamura, V. V. Dmitrenko, S. E. Ulin

    Research output: Contribution to journalArticle

    10 Citations (Scopus)

    Abstract

    The scintillation response to an α source (241Am) and the ionization yield in pure gaseous xenon and its mixtures with 0.2-2% of methane were measured at a pressure of 26 atm and different values of reduced electric field E/N. Both light and ionization yields in xenon were shown to decrease with increasing percentage of methane.

    Original languageEnglish
    Pages (from-to)489-493
    Number of pages5
    JournalInstruments and Experimental Techniques
    Volume49
    Issue number4
    DOIs
    Publication statusPublished - 2006 Jul

    Fingerprint

    Xenon
    Scintillation
    xenon
    scintillation
    Ionization
    Methane
    methane
    ionization
    Electric fields
    electric fields

    ASJC Scopus subject areas

    • Engineering (miscellaneous)
    • Instrumentation

    Cite this

    Pushkin, K. N., Hasebe, N., Tezuka, C., Kobayashi, S., Mimura, M., Hosojima, T., ... Ulin, S. E. (2006). A scintillation response and an ionization yield in pure xenon and mixtures of it with methane. Instruments and Experimental Techniques, 49(4), 489-493. https://doi.org/10.1134/S0020441206040063

    A scintillation response and an ionization yield in pure xenon and mixtures of it with methane. / Pushkin, K. N.; Hasebe, Nobuyuki; Tezuka, C.; Kobayashi, S.; Mimura, M.; Hosojima, T.; Doke, T.; Miyajima, M.; Miyachi, T.; Shibamura, E.; Dmitrenko, V. V.; Ulin, S. E.

    In: Instruments and Experimental Techniques, Vol. 49, No. 4, 07.2006, p. 489-493.

    Research output: Contribution to journalArticle

    Pushkin, KN, Hasebe, N, Tezuka, C, Kobayashi, S, Mimura, M, Hosojima, T, Doke, T, Miyajima, M, Miyachi, T, Shibamura, E, Dmitrenko, VV & Ulin, SE 2006, 'A scintillation response and an ionization yield in pure xenon and mixtures of it with methane', Instruments and Experimental Techniques, vol. 49, no. 4, pp. 489-493. https://doi.org/10.1134/S0020441206040063
    Pushkin, K. N. ; Hasebe, Nobuyuki ; Tezuka, C. ; Kobayashi, S. ; Mimura, M. ; Hosojima, T. ; Doke, T. ; Miyajima, M. ; Miyachi, T. ; Shibamura, E. ; Dmitrenko, V. V. ; Ulin, S. E. / A scintillation response and an ionization yield in pure xenon and mixtures of it with methane. In: Instruments and Experimental Techniques. 2006 ; Vol. 49, No. 4. pp. 489-493.
    @article{9d3f78cd6d4c40f594c240f10aea2fc0,
    title = "A scintillation response and an ionization yield in pure xenon and mixtures of it with methane",
    abstract = "The scintillation response to an α source (241Am) and the ionization yield in pure gaseous xenon and its mixtures with 0.2-2{\%} of methane were measured at a pressure of 26 atm and different values of reduced electric field E/N. Both light and ionization yields in xenon were shown to decrease with increasing percentage of methane.",
    author = "Pushkin, {K. N.} and Nobuyuki Hasebe and C. Tezuka and S. Kobayashi and M. Mimura and T. Hosojima and T. Doke and M. Miyajima and T. Miyachi and E. Shibamura and Dmitrenko, {V. V.} and Ulin, {S. E.}",
    year = "2006",
    month = "7",
    doi = "10.1134/S0020441206040063",
    language = "English",
    volume = "49",
    pages = "489--493",
    journal = "Instruments and Experimental Techniques",
    issn = "0020-4412",
    publisher = "Maik Nauka-Interperiodica Publishing",
    number = "4",

    }

    TY - JOUR

    T1 - A scintillation response and an ionization yield in pure xenon and mixtures of it with methane

    AU - Pushkin, K. N.

    AU - Hasebe, Nobuyuki

    AU - Tezuka, C.

    AU - Kobayashi, S.

    AU - Mimura, M.

    AU - Hosojima, T.

    AU - Doke, T.

    AU - Miyajima, M.

    AU - Miyachi, T.

    AU - Shibamura, E.

    AU - Dmitrenko, V. V.

    AU - Ulin, S. E.

    PY - 2006/7

    Y1 - 2006/7

    N2 - The scintillation response to an α source (241Am) and the ionization yield in pure gaseous xenon and its mixtures with 0.2-2% of methane were measured at a pressure of 26 atm and different values of reduced electric field E/N. Both light and ionization yields in xenon were shown to decrease with increasing percentage of methane.

    AB - The scintillation response to an α source (241Am) and the ionization yield in pure gaseous xenon and its mixtures with 0.2-2% of methane were measured at a pressure of 26 atm and different values of reduced electric field E/N. Both light and ionization yields in xenon were shown to decrease with increasing percentage of methane.

    UR - http://www.scopus.com/inward/record.url?scp=33747151657&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=33747151657&partnerID=8YFLogxK

    U2 - 10.1134/S0020441206040063

    DO - 10.1134/S0020441206040063

    M3 - Article

    AN - SCOPUS:33747151657

    VL - 49

    SP - 489

    EP - 493

    JO - Instruments and Experimental Techniques

    JF - Instruments and Experimental Techniques

    SN - 0020-4412

    IS - 4

    ER -