A study on EMTP-analysis model for switch-board SPD with gap and propagation characteristics of lightning surge on simple indoor distribution line

Yoshiki Sakamoto, Teru Miyazaki, Shigemitsu Okabe

Research output: Contribution to journalArticle

Abstract

The numbers of damages of home electric appliances due to lightning surges have recently increased. Installing Surge Protective Devices (SPDs) for indoor distribution line is one of countermeasures against the damages, and is also spreading after an amendment of the regulation on indoor wires in 2005. Past studies have showed that the SPDs installed on the switchboard are effective for protecting all the equipment supplied by indoor distribution lines against lightning strokes. However, it is difficult to evaluate the protective effects of the SPDs against lightning strikes when considering complex indoor wires in houses. Thus, a high-precision analysis method is required to clarify the lightning performance of the SPDs for interior wiring. In this research, experiments were conducted to grasp the protective effects of the SPDs installed on a switchboard against lightning surges invading into a house, and an analysis model by the EMTP was proposed. The calculated results relatively agreed with the experimental results.

Original languageEnglish
JournalIEEJ Transactions on Power and Energy
Volume129
Issue number7
DOIs
Publication statusPublished - 2009 Sep 21
Externally publishedYes

Fingerprint

Lightning
Switches
Electric appliances
Wire
Electric wiring
Experiments

Keywords

  • EMTP analysis model
  • Gap
  • Indoor distribution line
  • Lightning protection
  • Lightning surge
  • Surge protective device
  • Varistor

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

Cite this

A study on EMTP-analysis model for switch-board SPD with gap and propagation characteristics of lightning surge on simple indoor distribution line. / Sakamoto, Yoshiki; Miyazaki, Teru; Okabe, Shigemitsu.

In: IEEJ Transactions on Power and Energy, Vol. 129, No. 7, 21.09.2009.

Research output: Contribution to journalArticle

@article{a04d764ef08442d99714c465a84e3c9b,
title = "A study on EMTP-analysis model for switch-board SPD with gap and propagation characteristics of lightning surge on simple indoor distribution line",
abstract = "The numbers of damages of home electric appliances due to lightning surges have recently increased. Installing Surge Protective Devices (SPDs) for indoor distribution line is one of countermeasures against the damages, and is also spreading after an amendment of the regulation on indoor wires in 2005. Past studies have showed that the SPDs installed on the switchboard are effective for protecting all the equipment supplied by indoor distribution lines against lightning strokes. However, it is difficult to evaluate the protective effects of the SPDs against lightning strikes when considering complex indoor wires in houses. Thus, a high-precision analysis method is required to clarify the lightning performance of the SPDs for interior wiring. In this research, experiments were conducted to grasp the protective effects of the SPDs installed on a switchboard against lightning surges invading into a house, and an analysis model by the EMTP was proposed. The calculated results relatively agreed with the experimental results.",
keywords = "EMTP analysis model, Gap, Indoor distribution line, Lightning protection, Lightning surge, Surge protective device, Varistor",
author = "Yoshiki Sakamoto and Teru Miyazaki and Shigemitsu Okabe",
year = "2009",
month = "9",
day = "21",
doi = "10.1541/ieejpes.129.914",
language = "English",
volume = "129",
journal = "IEEJ Transactions on Power and Energy",
issn = "0385-4213",
publisher = "The Institute of Electrical Engineers of Japan",
number = "7",

}

TY - JOUR

T1 - A study on EMTP-analysis model for switch-board SPD with gap and propagation characteristics of lightning surge on simple indoor distribution line

AU - Sakamoto, Yoshiki

AU - Miyazaki, Teru

AU - Okabe, Shigemitsu

PY - 2009/9/21

Y1 - 2009/9/21

N2 - The numbers of damages of home electric appliances due to lightning surges have recently increased. Installing Surge Protective Devices (SPDs) for indoor distribution line is one of countermeasures against the damages, and is also spreading after an amendment of the regulation on indoor wires in 2005. Past studies have showed that the SPDs installed on the switchboard are effective for protecting all the equipment supplied by indoor distribution lines against lightning strokes. However, it is difficult to evaluate the protective effects of the SPDs against lightning strikes when considering complex indoor wires in houses. Thus, a high-precision analysis method is required to clarify the lightning performance of the SPDs for interior wiring. In this research, experiments were conducted to grasp the protective effects of the SPDs installed on a switchboard against lightning surges invading into a house, and an analysis model by the EMTP was proposed. The calculated results relatively agreed with the experimental results.

AB - The numbers of damages of home electric appliances due to lightning surges have recently increased. Installing Surge Protective Devices (SPDs) for indoor distribution line is one of countermeasures against the damages, and is also spreading after an amendment of the regulation on indoor wires in 2005. Past studies have showed that the SPDs installed on the switchboard are effective for protecting all the equipment supplied by indoor distribution lines against lightning strokes. However, it is difficult to evaluate the protective effects of the SPDs against lightning strikes when considering complex indoor wires in houses. Thus, a high-precision analysis method is required to clarify the lightning performance of the SPDs for interior wiring. In this research, experiments were conducted to grasp the protective effects of the SPDs installed on a switchboard against lightning surges invading into a house, and an analysis model by the EMTP was proposed. The calculated results relatively agreed with the experimental results.

KW - EMTP analysis model

KW - Gap

KW - Indoor distribution line

KW - Lightning protection

KW - Lightning surge

KW - Surge protective device

KW - Varistor

UR - http://www.scopus.com/inward/record.url?scp=70349126249&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70349126249&partnerID=8YFLogxK

U2 - 10.1541/ieejpes.129.914

DO - 10.1541/ieejpes.129.914

M3 - Article

VL - 129

JO - IEEJ Transactions on Power and Energy

JF - IEEJ Transactions on Power and Energy

SN - 0385-4213

IS - 7

ER -