A study on the estimation of energy consumption rate of accommodation buildings - Analysis based on survey data in 2009 fiscal year on the database of energy consumption for commercial buildings (DECC): Part 2

Yorimasa Iki, Satoshi Sudo, Hiroshi Yoshino, Shuzo Murakami, Kazuaki Bogaki, Katashi Matsunawa, Shigeki Kametani, Hiroto Takaguchi, Hisashi Hanzawa, Masaya Okumiya, Yoshiharu Asano, Yoshiyuki Shimoda, Saburo Murakawa, Hirotoshi Yoda, Hideki Tanaka, Yukihiro Masuda

    Research output: Contribution to journalArticle

    2 Citations (Scopus)

    Abstract

    In this study we aimed to identify characteristics of energy consumption of accommodation building by drawing on 2009 fiscal year of DECC survey data. Conducting statistical analysis on the base-load and the fluctuation-load on a national scale derived from patterns of variation in the monthly energy consumption, we obtained estimation equations for energy consumption rate. To determine the base-load rate, we focused on differences between heat-generation equipments in the accommodation buildings and classified them into three categories: electrical, fuel-based, and electric-fuel hybrid. We then carried out the multiple regression analysis for each category. As a result, we obtained accurate estimation equations for the electrical and the fuel-based heat-generation equipments. And to determine the summer and the winter fluctuation-load rate, we were able to obtain accurate estimation equations using the multiple regression analysis.

    Original languageEnglish
    Pages (from-to)45-54
    Number of pages10
    JournalJournal of Environmental Engineering (Japan)
    Volume78
    Issue number683
    DOIs
    Publication statusPublished - 2013 Jan

    Fingerprint

    Energy utilization
    Heat generation
    Regression analysis
    Statistical methods

    Keywords

    • Accommodation Building
    • Base-Load
    • Energy Consumption Rate
    • Estimation Equation
    • Fluctuation-Load
    • Multiple Regression Analysis

    ASJC Scopus subject areas

    • Environmental Engineering

    Cite this

    A study on the estimation of energy consumption rate of accommodation buildings - Analysis based on survey data in 2009 fiscal year on the database of energy consumption for commercial buildings (DECC) : Part 2. / Iki, Yorimasa; Sudo, Satoshi; Yoshino, Hiroshi; Murakami, Shuzo; Bogaki, Kazuaki; Matsunawa, Katashi; Kametani, Shigeki; Takaguchi, Hiroto; Hanzawa, Hisashi; Okumiya, Masaya; Asano, Yoshiharu; Shimoda, Yoshiyuki; Murakawa, Saburo; Yoda, Hirotoshi; Tanaka, Hideki; Masuda, Yukihiro.

    In: Journal of Environmental Engineering (Japan), Vol. 78, No. 683, 01.2013, p. 45-54.

    Research output: Contribution to journalArticle

    Iki, Y, Sudo, S, Yoshino, H, Murakami, S, Bogaki, K, Matsunawa, K, Kametani, S, Takaguchi, H, Hanzawa, H, Okumiya, M, Asano, Y, Shimoda, Y, Murakawa, S, Yoda, H, Tanaka, H & Masuda, Y 2013, 'A study on the estimation of energy consumption rate of accommodation buildings - Analysis based on survey data in 2009 fiscal year on the database of energy consumption for commercial buildings (DECC): Part 2', Journal of Environmental Engineering (Japan), vol. 78, no. 683, pp. 45-54. https://doi.org/10.3130/aije.78.45
    Iki, Yorimasa ; Sudo, Satoshi ; Yoshino, Hiroshi ; Murakami, Shuzo ; Bogaki, Kazuaki ; Matsunawa, Katashi ; Kametani, Shigeki ; Takaguchi, Hiroto ; Hanzawa, Hisashi ; Okumiya, Masaya ; Asano, Yoshiharu ; Shimoda, Yoshiyuki ; Murakawa, Saburo ; Yoda, Hirotoshi ; Tanaka, Hideki ; Masuda, Yukihiro. / A study on the estimation of energy consumption rate of accommodation buildings - Analysis based on survey data in 2009 fiscal year on the database of energy consumption for commercial buildings (DECC) : Part 2. In: Journal of Environmental Engineering (Japan). 2013 ; Vol. 78, No. 683. pp. 45-54.
    @article{984a19cf9f424ee396226766f04dcfd9,
    title = "A study on the estimation of energy consumption rate of accommodation buildings - Analysis based on survey data in 2009 fiscal year on the database of energy consumption for commercial buildings (DECC): Part 2",
    abstract = "In this study we aimed to identify characteristics of energy consumption of accommodation building by drawing on 2009 fiscal year of DECC survey data. Conducting statistical analysis on the base-load and the fluctuation-load on a national scale derived from patterns of variation in the monthly energy consumption, we obtained estimation equations for energy consumption rate. To determine the base-load rate, we focused on differences between heat-generation equipments in the accommodation buildings and classified them into three categories: electrical, fuel-based, and electric-fuel hybrid. We then carried out the multiple regression analysis for each category. As a result, we obtained accurate estimation equations for the electrical and the fuel-based heat-generation equipments. And to determine the summer and the winter fluctuation-load rate, we were able to obtain accurate estimation equations using the multiple regression analysis.",
    keywords = "Accommodation Building, Base-Load, Energy Consumption Rate, Estimation Equation, Fluctuation-Load, Multiple Regression Analysis",
    author = "Yorimasa Iki and Satoshi Sudo and Hiroshi Yoshino and Shuzo Murakami and Kazuaki Bogaki and Katashi Matsunawa and Shigeki Kametani and Hiroto Takaguchi and Hisashi Hanzawa and Masaya Okumiya and Yoshiharu Asano and Yoshiyuki Shimoda and Saburo Murakawa and Hirotoshi Yoda and Hideki Tanaka and Yukihiro Masuda",
    year = "2013",
    month = "1",
    doi = "10.3130/aije.78.45",
    language = "English",
    volume = "78",
    pages = "45--54",
    journal = "Journal of Environmental Engineering, ASCE",
    issn = "1348-0685",
    publisher = "American Society of Civil Engineers (ASCE)",
    number = "683",

    }

    TY - JOUR

    T1 - A study on the estimation of energy consumption rate of accommodation buildings - Analysis based on survey data in 2009 fiscal year on the database of energy consumption for commercial buildings (DECC)

    T2 - Part 2

    AU - Iki, Yorimasa

    AU - Sudo, Satoshi

    AU - Yoshino, Hiroshi

    AU - Murakami, Shuzo

    AU - Bogaki, Kazuaki

    AU - Matsunawa, Katashi

    AU - Kametani, Shigeki

    AU - Takaguchi, Hiroto

    AU - Hanzawa, Hisashi

    AU - Okumiya, Masaya

    AU - Asano, Yoshiharu

    AU - Shimoda, Yoshiyuki

    AU - Murakawa, Saburo

    AU - Yoda, Hirotoshi

    AU - Tanaka, Hideki

    AU - Masuda, Yukihiro

    PY - 2013/1

    Y1 - 2013/1

    N2 - In this study we aimed to identify characteristics of energy consumption of accommodation building by drawing on 2009 fiscal year of DECC survey data. Conducting statistical analysis on the base-load and the fluctuation-load on a national scale derived from patterns of variation in the monthly energy consumption, we obtained estimation equations for energy consumption rate. To determine the base-load rate, we focused on differences between heat-generation equipments in the accommodation buildings and classified them into three categories: electrical, fuel-based, and electric-fuel hybrid. We then carried out the multiple regression analysis for each category. As a result, we obtained accurate estimation equations for the electrical and the fuel-based heat-generation equipments. And to determine the summer and the winter fluctuation-load rate, we were able to obtain accurate estimation equations using the multiple regression analysis.

    AB - In this study we aimed to identify characteristics of energy consumption of accommodation building by drawing on 2009 fiscal year of DECC survey data. Conducting statistical analysis on the base-load and the fluctuation-load on a national scale derived from patterns of variation in the monthly energy consumption, we obtained estimation equations for energy consumption rate. To determine the base-load rate, we focused on differences between heat-generation equipments in the accommodation buildings and classified them into three categories: electrical, fuel-based, and electric-fuel hybrid. We then carried out the multiple regression analysis for each category. As a result, we obtained accurate estimation equations for the electrical and the fuel-based heat-generation equipments. And to determine the summer and the winter fluctuation-load rate, we were able to obtain accurate estimation equations using the multiple regression analysis.

    KW - Accommodation Building

    KW - Base-Load

    KW - Energy Consumption Rate

    KW - Estimation Equation

    KW - Fluctuation-Load

    KW - Multiple Regression Analysis

    UR - http://www.scopus.com/inward/record.url?scp=84878935548&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84878935548&partnerID=8YFLogxK

    U2 - 10.3130/aije.78.45

    DO - 10.3130/aije.78.45

    M3 - Article

    AN - SCOPUS:84878935548

    VL - 78

    SP - 45

    EP - 54

    JO - Journal of Environmental Engineering, ASCE

    JF - Journal of Environmental Engineering, ASCE

    SN - 1348-0685

    IS - 683

    ER -