A study on the transmission power in dynamic contactless power transmission

Shogo Shibata, Febry Pandu Wijaya, Keiichiro Kondo

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

In this study, the contactless power transmission system to supply intermittent power to the railway vehicle equipped with energy storage device is assumed. The maintenance cost reduction is expected compared to line-pantograph charging method. In order to reduce the amount of energy storage device and loss in the converters, the combination of static and dynamic power transmission are assumed. The configuration of air-core ground coil and using core in the onboard coil are desirable to reduce the installation costs. However, due to the decrease of coupling factor, the input current and the secondary compensation current will increase, which limit the transmission power. In addition, the transmission power is also affected by the turn number of ground coil and the resonant frequency. The scaled down experimental system is utilized to reveal the maximum transmitted power and its limitation of the dynamic contactless charging method.

Original languageEnglish
Title of host publicationProceedings - 2016 IEEE International Conference on Industrial Technology, ICIT 2016
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages245-250
Number of pages6
Volume2016-May
ISBN (Electronic)9781467380751
DOIs
Publication statusPublished - 2016 May 19
Externally publishedYes
EventIEEE International Conference on Industrial Technology, ICIT 2016 - Taipei, Taiwan, Province of China
Duration: 2016 Mar 142016 Mar 17

Other

OtherIEEE International Conference on Industrial Technology, ICIT 2016
CountryTaiwan, Province of China
CityTaipei
Period16/3/1416/3/17

Fingerprint

Power transmission
Energy storage
Pantographs
Cost reduction
Natural frequencies
Air
Costs

Keywords

  • contactless power transmission system
  • current limitation
  • dynamic power transmission

ASJC Scopus subject areas

  • Computer Science Applications
  • Electrical and Electronic Engineering

Cite this

Shibata, S., Wijaya, F. P., & Kondo, K. (2016). A study on the transmission power in dynamic contactless power transmission. In Proceedings - 2016 IEEE International Conference on Industrial Technology, ICIT 2016 (Vol. 2016-May, pp. 245-250). [7474759] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ICIT.2016.7474759

A study on the transmission power in dynamic contactless power transmission. / Shibata, Shogo; Wijaya, Febry Pandu; Kondo, Keiichiro.

Proceedings - 2016 IEEE International Conference on Industrial Technology, ICIT 2016. Vol. 2016-May Institute of Electrical and Electronics Engineers Inc., 2016. p. 245-250 7474759.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Shibata, S, Wijaya, FP & Kondo, K 2016, A study on the transmission power in dynamic contactless power transmission. in Proceedings - 2016 IEEE International Conference on Industrial Technology, ICIT 2016. vol. 2016-May, 7474759, Institute of Electrical and Electronics Engineers Inc., pp. 245-250, IEEE International Conference on Industrial Technology, ICIT 2016, Taipei, Taiwan, Province of China, 16/3/14. https://doi.org/10.1109/ICIT.2016.7474759
Shibata S, Wijaya FP, Kondo K. A study on the transmission power in dynamic contactless power transmission. In Proceedings - 2016 IEEE International Conference on Industrial Technology, ICIT 2016. Vol. 2016-May. Institute of Electrical and Electronics Engineers Inc. 2016. p. 245-250. 7474759 https://doi.org/10.1109/ICIT.2016.7474759
Shibata, Shogo ; Wijaya, Febry Pandu ; Kondo, Keiichiro. / A study on the transmission power in dynamic contactless power transmission. Proceedings - 2016 IEEE International Conference on Industrial Technology, ICIT 2016. Vol. 2016-May Institute of Electrical and Electronics Engineers Inc., 2016. pp. 245-250
@inproceedings{de0a283f879042eb8454ca1b3d26237d,
title = "A study on the transmission power in dynamic contactless power transmission",
abstract = "In this study, the contactless power transmission system to supply intermittent power to the railway vehicle equipped with energy storage device is assumed. The maintenance cost reduction is expected compared to line-pantograph charging method. In order to reduce the amount of energy storage device and loss in the converters, the combination of static and dynamic power transmission are assumed. The configuration of air-core ground coil and using core in the onboard coil are desirable to reduce the installation costs. However, due to the decrease of coupling factor, the input current and the secondary compensation current will increase, which limit the transmission power. In addition, the transmission power is also affected by the turn number of ground coil and the resonant frequency. The scaled down experimental system is utilized to reveal the maximum transmitted power and its limitation of the dynamic contactless charging method.",
keywords = "contactless power transmission system, current limitation, dynamic power transmission",
author = "Shogo Shibata and Wijaya, {Febry Pandu} and Keiichiro Kondo",
year = "2016",
month = "5",
day = "19",
doi = "10.1109/ICIT.2016.7474759",
language = "English",
volume = "2016-May",
pages = "245--250",
booktitle = "Proceedings - 2016 IEEE International Conference on Industrial Technology, ICIT 2016",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - A study on the transmission power in dynamic contactless power transmission

AU - Shibata, Shogo

AU - Wijaya, Febry Pandu

AU - Kondo, Keiichiro

PY - 2016/5/19

Y1 - 2016/5/19

N2 - In this study, the contactless power transmission system to supply intermittent power to the railway vehicle equipped with energy storage device is assumed. The maintenance cost reduction is expected compared to line-pantograph charging method. In order to reduce the amount of energy storage device and loss in the converters, the combination of static and dynamic power transmission are assumed. The configuration of air-core ground coil and using core in the onboard coil are desirable to reduce the installation costs. However, due to the decrease of coupling factor, the input current and the secondary compensation current will increase, which limit the transmission power. In addition, the transmission power is also affected by the turn number of ground coil and the resonant frequency. The scaled down experimental system is utilized to reveal the maximum transmitted power and its limitation of the dynamic contactless charging method.

AB - In this study, the contactless power transmission system to supply intermittent power to the railway vehicle equipped with energy storage device is assumed. The maintenance cost reduction is expected compared to line-pantograph charging method. In order to reduce the amount of energy storage device and loss in the converters, the combination of static and dynamic power transmission are assumed. The configuration of air-core ground coil and using core in the onboard coil are desirable to reduce the installation costs. However, due to the decrease of coupling factor, the input current and the secondary compensation current will increase, which limit the transmission power. In addition, the transmission power is also affected by the turn number of ground coil and the resonant frequency. The scaled down experimental system is utilized to reveal the maximum transmitted power and its limitation of the dynamic contactless charging method.

KW - contactless power transmission system

KW - current limitation

KW - dynamic power transmission

UR - http://www.scopus.com/inward/record.url?scp=84974603924&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84974603924&partnerID=8YFLogxK

U2 - 10.1109/ICIT.2016.7474759

DO - 10.1109/ICIT.2016.7474759

M3 - Conference contribution

AN - SCOPUS:84974603924

VL - 2016-May

SP - 245

EP - 250

BT - Proceedings - 2016 IEEE International Conference on Industrial Technology, ICIT 2016

PB - Institute of Electrical and Electronics Engineers Inc.

ER -