Advanced spectrometer with two spectral channels sharing the same BSI-CMOS detector

Kai Yan Zang, Yuan Yao, Er Tao Hu, An Qing Jiang, Yu Xiang Zheng, Song You Wang, Hai Bin Zhao, Yue Mei Yang, Osamu Yoshie, Young Pak Lee, David W. Lynch, Liang Yao Chen

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

By consisting of 8 sub-gratings to image two sets of 4-folded spectra on the focal plane of a BSI-CMOS detector, a two-channel spectrometer with a resolution of better than 0.1 nm/pixel in the 200- 950-nm spectral range is studied with the result measured for the Hg-Ar lamp.

Original languageEnglish
Title of host publicationCLEO
Subtitle of host publicationApplications and Technology, CLEO_AT 2019
PublisherOSA - The Optical Society
ISBN (Electronic)9781557528209
DOIs
Publication statusPublished - 2019 Jan 1
EventCLEO: Applications and Technology, CLEO_AT 2019 - San Jose, United States
Duration: 2019 May 52019 May 10

Publication series

NameOptics InfoBase Conference Papers
VolumePart F127-CLEO_AT 2019

Conference

ConferenceCLEO: Applications and Technology, CLEO_AT 2019
CountryUnited States
CitySan Jose
Period19/5/519/5/10

Fingerprint

Electric lamps
Spectrometers
Pixels
Detectors

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Mechanics of Materials

Cite this

Zang, K. Y., Yao, Y., Hu, E. T., Jiang, A. Q., Zheng, Y. X., Wang, S. Y., ... Chen, L. Y. (2019). Advanced spectrometer with two spectral channels sharing the same BSI-CMOS detector. In CLEO: Applications and Technology, CLEO_AT 2019 (Optics InfoBase Conference Papers; Vol. Part F127-CLEO_AT 2019). OSA - The Optical Society. https://doi.org/10.1364/CLEO_AT.2019.JW2A.11

Advanced spectrometer with two spectral channels sharing the same BSI-CMOS detector. / Zang, Kai Yan; Yao, Yuan; Hu, Er Tao; Jiang, An Qing; Zheng, Yu Xiang; Wang, Song You; Zhao, Hai Bin; Yang, Yue Mei; Yoshie, Osamu; Lee, Young Pak; Lynch, David W.; Chen, Liang Yao.

CLEO: Applications and Technology, CLEO_AT 2019. OSA - The Optical Society, 2019. (Optics InfoBase Conference Papers; Vol. Part F127-CLEO_AT 2019).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Zang, KY, Yao, Y, Hu, ET, Jiang, AQ, Zheng, YX, Wang, SY, Zhao, HB, Yang, YM, Yoshie, O, Lee, YP, Lynch, DW & Chen, LY 2019, Advanced spectrometer with two spectral channels sharing the same BSI-CMOS detector. in CLEO: Applications and Technology, CLEO_AT 2019. Optics InfoBase Conference Papers, vol. Part F127-CLEO_AT 2019, OSA - The Optical Society, CLEO: Applications and Technology, CLEO_AT 2019, San Jose, United States, 19/5/5. https://doi.org/10.1364/CLEO_AT.2019.JW2A.11
Zang KY, Yao Y, Hu ET, Jiang AQ, Zheng YX, Wang SY et al. Advanced spectrometer with two spectral channels sharing the same BSI-CMOS detector. In CLEO: Applications and Technology, CLEO_AT 2019. OSA - The Optical Society. 2019. (Optics InfoBase Conference Papers). https://doi.org/10.1364/CLEO_AT.2019.JW2A.11
Zang, Kai Yan ; Yao, Yuan ; Hu, Er Tao ; Jiang, An Qing ; Zheng, Yu Xiang ; Wang, Song You ; Zhao, Hai Bin ; Yang, Yue Mei ; Yoshie, Osamu ; Lee, Young Pak ; Lynch, David W. ; Chen, Liang Yao. / Advanced spectrometer with two spectral channels sharing the same BSI-CMOS detector. CLEO: Applications and Technology, CLEO_AT 2019. OSA - The Optical Society, 2019. (Optics InfoBase Conference Papers).
@inproceedings{8cf5ae7154ae4cc29811175e6c2d22f4,
title = "Advanced spectrometer with two spectral channels sharing the same BSI-CMOS detector",
abstract = "By consisting of 8 sub-gratings to image two sets of 4-folded spectra on the focal plane of a BSI-CMOS detector, a two-channel spectrometer with a resolution of better than 0.1 nm/pixel in the 200- 950-nm spectral range is studied with the result measured for the Hg-Ar lamp.",
author = "Zang, {Kai Yan} and Yuan Yao and Hu, {Er Tao} and Jiang, {An Qing} and Zheng, {Yu Xiang} and Wang, {Song You} and Zhao, {Hai Bin} and Yang, {Yue Mei} and Osamu Yoshie and Lee, {Young Pak} and Lynch, {David W.} and Chen, {Liang Yao}",
year = "2019",
month = "1",
day = "1",
doi = "10.1364/CLEO_AT.2019.JW2A.11",
language = "English",
series = "Optics InfoBase Conference Papers",
publisher = "OSA - The Optical Society",
booktitle = "CLEO",

}

TY - GEN

T1 - Advanced spectrometer with two spectral channels sharing the same BSI-CMOS detector

AU - Zang, Kai Yan

AU - Yao, Yuan

AU - Hu, Er Tao

AU - Jiang, An Qing

AU - Zheng, Yu Xiang

AU - Wang, Song You

AU - Zhao, Hai Bin

AU - Yang, Yue Mei

AU - Yoshie, Osamu

AU - Lee, Young Pak

AU - Lynch, David W.

AU - Chen, Liang Yao

PY - 2019/1/1

Y1 - 2019/1/1

N2 - By consisting of 8 sub-gratings to image two sets of 4-folded spectra on the focal plane of a BSI-CMOS detector, a two-channel spectrometer with a resolution of better than 0.1 nm/pixel in the 200- 950-nm spectral range is studied with the result measured for the Hg-Ar lamp.

AB - By consisting of 8 sub-gratings to image two sets of 4-folded spectra on the focal plane of a BSI-CMOS detector, a two-channel spectrometer with a resolution of better than 0.1 nm/pixel in the 200- 950-nm spectral range is studied with the result measured for the Hg-Ar lamp.

UR - http://www.scopus.com/inward/record.url?scp=85068127230&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85068127230&partnerID=8YFLogxK

U2 - 10.1364/CLEO_AT.2019.JW2A.11

DO - 10.1364/CLEO_AT.2019.JW2A.11

M3 - Conference contribution

AN - SCOPUS:85068127230

T3 - Optics InfoBase Conference Papers

BT - CLEO

PB - OSA - The Optical Society

ER -