Albumin transport across the endothelial cells under the shear stress applied

Masanori Tsuzaka, Makoto Takenouchi, Mariko Ikeda, Kotaro Oka, Kazuo Tanishita

Research output: Chapter in Book/Report/Conference proceedingChapter

1 Citation (Scopus)

Abstract

A system was developed to measure the permeability of albumin and inulin across the endothelial cell layer cultured on the surface of porous membrane with the shear stress applied. The measurement system consists of the perfusion and diffusion chambers separated by endothelial monolayer. The permeability of albumin was observed as a function of elapsed time.

Original languageEnglish
Title of host publicationAmerican Society of Mechanical Engineers, Bioengineering Division (Publication) BED
Place of PublicationFairfield, NJ, United States
PublisherASME
Pages293-294
Number of pages2
Volume42
ISBN (Print)0791816117
Publication statusPublished - 1999
Externally publishedYes
Event1999 Bioengineering Conference - Big Sky, MT, USA
Duration: 1999 Jun 161999 Jun 20

Other

Other1999 Bioengineering Conference
CityBig Sky, MT, USA
Period99/6/1699/6/20

Fingerprint

Endothelial cells
Shear stress
Monolayers
Membranes
Inulin

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Tsuzaka, M., Takenouchi, M., Ikeda, M., Oka, K., & Tanishita, K. (1999). Albumin transport across the endothelial cells under the shear stress applied. In American Society of Mechanical Engineers, Bioengineering Division (Publication) BED (Vol. 42, pp. 293-294). Fairfield, NJ, United States: ASME.

Albumin transport across the endothelial cells under the shear stress applied. / Tsuzaka, Masanori; Takenouchi, Makoto; Ikeda, Mariko; Oka, Kotaro; Tanishita, Kazuo.

American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. Vol. 42 Fairfield, NJ, United States : ASME, 1999. p. 293-294.

Research output: Chapter in Book/Report/Conference proceedingChapter

Tsuzaka, M, Takenouchi, M, Ikeda, M, Oka, K & Tanishita, K 1999, Albumin transport across the endothelial cells under the shear stress applied. in American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. vol. 42, ASME, Fairfield, NJ, United States, pp. 293-294, 1999 Bioengineering Conference, Big Sky, MT, USA, 99/6/16.
Tsuzaka M, Takenouchi M, Ikeda M, Oka K, Tanishita K. Albumin transport across the endothelial cells under the shear stress applied. In American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. Vol. 42. Fairfield, NJ, United States: ASME. 1999. p. 293-294
Tsuzaka, Masanori ; Takenouchi, Makoto ; Ikeda, Mariko ; Oka, Kotaro ; Tanishita, Kazuo. / Albumin transport across the endothelial cells under the shear stress applied. American Society of Mechanical Engineers, Bioengineering Division (Publication) BED. Vol. 42 Fairfield, NJ, United States : ASME, 1999. pp. 293-294
@inbook{105604be25204b1982efbca8024e67ee,
title = "Albumin transport across the endothelial cells under the shear stress applied",
abstract = "A system was developed to measure the permeability of albumin and inulin across the endothelial cell layer cultured on the surface of porous membrane with the shear stress applied. The measurement system consists of the perfusion and diffusion chambers separated by endothelial monolayer. The permeability of albumin was observed as a function of elapsed time.",
author = "Masanori Tsuzaka and Makoto Takenouchi and Mariko Ikeda and Kotaro Oka and Kazuo Tanishita",
year = "1999",
language = "English",
isbn = "0791816117",
volume = "42",
pages = "293--294",
booktitle = "American Society of Mechanical Engineers, Bioengineering Division (Publication) BED",
publisher = "ASME",

}

TY - CHAP

T1 - Albumin transport across the endothelial cells under the shear stress applied

AU - Tsuzaka, Masanori

AU - Takenouchi, Makoto

AU - Ikeda, Mariko

AU - Oka, Kotaro

AU - Tanishita, Kazuo

PY - 1999

Y1 - 1999

N2 - A system was developed to measure the permeability of albumin and inulin across the endothelial cell layer cultured on the surface of porous membrane with the shear stress applied. The measurement system consists of the perfusion and diffusion chambers separated by endothelial monolayer. The permeability of albumin was observed as a function of elapsed time.

AB - A system was developed to measure the permeability of albumin and inulin across the endothelial cell layer cultured on the surface of porous membrane with the shear stress applied. The measurement system consists of the perfusion and diffusion chambers separated by endothelial monolayer. The permeability of albumin was observed as a function of elapsed time.

UR - http://www.scopus.com/inward/record.url?scp=0033300154&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033300154&partnerID=8YFLogxK

M3 - Chapter

AN - SCOPUS:0033300154

SN - 0791816117

VL - 42

SP - 293

EP - 294

BT - American Society of Mechanical Engineers, Bioengineering Division (Publication) BED

PB - ASME

CY - Fairfield, NJ, United States

ER -