An evaluation technique of the fatigue analysis of an ankle-foot-orthosis in the design process

Yasuhiro Mine, Takamichi Takashima, Hiroshi Fujimoto

Research output: Contribution to journalArticle

Abstract

We have studied concerning the design technique of ankle-foot orthosis (AFO) that is used spastic hemiplegia of the stroke. We developed the equipment for measurement in order to measure the influence which it causes to spasticity gait. The ankle joint moments are calculated by the measurement data. In addition, you appraised of gait lability as the scatter plot by the angle and the moment of ankle joint in heel contact. These appraisal results were made the element which selects the orthosis. The design of the orthosis was utilized three dimensional cad, and the structural of the orthosis was analyzed the non-linear finite element analysis by the boundary condition which utilizes the measurement data. In this study, the life prediction of the orthosis which deals with 2 orthosis users was made help of the design factor. In order to investigate the life cycle of the orthosis user, the number of steps and living conditions were investigated. As for material definition S-N curve of the PP material was used. The result of fatigue analysis, it was suggested that fatigue analysis of the orthosis is effective as the help in orthosis designing.

Original languageEnglish
Pages (from-to)884-889
Number of pages6
JournalNihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C
Volume74
Issue number4
Publication statusPublished - 2008 Apr
Externally publishedYes

Fingerprint

Fatigue of materials
Life cycle
Boundary conditions
Finite element method

Keywords

  • 3D design
  • Fatigue analysis
  • Finite element method
  • Hemiplegies gait
  • Life prediction
  • Measurement
  • Spasticity

ASJC Scopus subject areas

  • Mechanical Engineering

Cite this

@article{a027b4501567486b838fff7acd0b1d75,
title = "An evaluation technique of the fatigue analysis of an ankle-foot-orthosis in the design process",
abstract = "We have studied concerning the design technique of ankle-foot orthosis (AFO) that is used spastic hemiplegia of the stroke. We developed the equipment for measurement in order to measure the influence which it causes to spasticity gait. The ankle joint moments are calculated by the measurement data. In addition, you appraised of gait lability as the scatter plot by the angle and the moment of ankle joint in heel contact. These appraisal results were made the element which selects the orthosis. The design of the orthosis was utilized three dimensional cad, and the structural of the orthosis was analyzed the non-linear finite element analysis by the boundary condition which utilizes the measurement data. In this study, the life prediction of the orthosis which deals with 2 orthosis users was made help of the design factor. In order to investigate the life cycle of the orthosis user, the number of steps and living conditions were investigated. As for material definition S-N curve of the PP material was used. The result of fatigue analysis, it was suggested that fatigue analysis of the orthosis is effective as the help in orthosis designing.",
keywords = "3D design, Fatigue analysis, Finite element method, Hemiplegies gait, Life prediction, Measurement, Spasticity",
author = "Yasuhiro Mine and Takamichi Takashima and Hiroshi Fujimoto",
year = "2008",
month = "4",
language = "English",
volume = "74",
pages = "884--889",
journal = "Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C",
issn = "0387-5024",
publisher = "Japan Society of Mechanical Engineers",
number = "4",

}

TY - JOUR

T1 - An evaluation technique of the fatigue analysis of an ankle-foot-orthosis in the design process

AU - Mine, Yasuhiro

AU - Takashima, Takamichi

AU - Fujimoto, Hiroshi

PY - 2008/4

Y1 - 2008/4

N2 - We have studied concerning the design technique of ankle-foot orthosis (AFO) that is used spastic hemiplegia of the stroke. We developed the equipment for measurement in order to measure the influence which it causes to spasticity gait. The ankle joint moments are calculated by the measurement data. In addition, you appraised of gait lability as the scatter plot by the angle and the moment of ankle joint in heel contact. These appraisal results were made the element which selects the orthosis. The design of the orthosis was utilized three dimensional cad, and the structural of the orthosis was analyzed the non-linear finite element analysis by the boundary condition which utilizes the measurement data. In this study, the life prediction of the orthosis which deals with 2 orthosis users was made help of the design factor. In order to investigate the life cycle of the orthosis user, the number of steps and living conditions were investigated. As for material definition S-N curve of the PP material was used. The result of fatigue analysis, it was suggested that fatigue analysis of the orthosis is effective as the help in orthosis designing.

AB - We have studied concerning the design technique of ankle-foot orthosis (AFO) that is used spastic hemiplegia of the stroke. We developed the equipment for measurement in order to measure the influence which it causes to spasticity gait. The ankle joint moments are calculated by the measurement data. In addition, you appraised of gait lability as the scatter plot by the angle and the moment of ankle joint in heel contact. These appraisal results were made the element which selects the orthosis. The design of the orthosis was utilized three dimensional cad, and the structural of the orthosis was analyzed the non-linear finite element analysis by the boundary condition which utilizes the measurement data. In this study, the life prediction of the orthosis which deals with 2 orthosis users was made help of the design factor. In order to investigate the life cycle of the orthosis user, the number of steps and living conditions were investigated. As for material definition S-N curve of the PP material was used. The result of fatigue analysis, it was suggested that fatigue analysis of the orthosis is effective as the help in orthosis designing.

KW - 3D design

KW - Fatigue analysis

KW - Finite element method

KW - Hemiplegies gait

KW - Life prediction

KW - Measurement

KW - Spasticity

UR - http://www.scopus.com/inward/record.url?scp=48249144128&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=48249144128&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:48249144128

VL - 74

SP - 884

EP - 889

JO - Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C

JF - Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C

SN - 0387-5024

IS - 4

ER -