An experimental study on fabricating an inverted mesa-type quartz crystal resonator using a cheap wet etching process

Jinxing Liang, Jia Huang, Tian Zhang, Jing Zhang, Xuefeng Li, Toshitsugu Ueda

    Research output: Contribution to journalArticle

    8 Citations (Scopus)

    Abstract

    In this study, a miniaturized high fundamental frequency quartz crystal microbalance (QCM) is fabricated for sensor applications using a wet etching technique. The vibration area is reduced in the fabrication of the high frequency QCM with an inverted mesa structure. To reduce the complexity of the side wall profile that results from anisotropic quartz etching, a rectangular vibration area is used instead of the conventional circular structure. QCMs with high Q values exceeding 25,000 at 47 MHz, 27,000 at 60 MHz, 24,000 at 73 MHz and 25,000 at 84 MHz are fabricated on 4 × 4 mm2chips with small vibration areas of 1.2 × 1.4 mm2. A PMMA-based flow cell is designed and manufactured to characterize the behavior of the fabricated QCM chip in a liquid. Q values as high as 1,006 at 47 MHz, 904 at 62 MHz, 867 at 71 MHz and 747 at 84 MHz are obtained when one side of the chip is exposed to pure water. These results show that fabricated QCM chips can be used for bio- and chemical sensor applications in liquids.

    Original languageEnglish
    Pages (from-to)12140-12148
    Number of pages9
    JournalSensors (Switzerland)
    Volume13
    Issue number9
    DOIs
    Publication statusPublished - 2013 Sep 10

    Fingerprint

    Quartz Crystal Microbalance Techniques
    Crystal resonators
    Quartz
    Wet etching
    Quartz crystal microbalances
    mesas
    quartz crystals
    microbalances
    Vibration
    resonators
    etching
    chips
    vibration
    sensors
    Liquids
    Polymethyl Methacrylate
    liquids
    Chemical sensors
    Q factors
    Etching

    Keywords

    • High
    • High fundamental frequency
    • Quartz crystal microbalance
    • Rectangle
    • Value
    • Wet etching process

    ASJC Scopus subject areas

    • Electrical and Electronic Engineering
    • Atomic and Molecular Physics, and Optics
    • Analytical Chemistry
    • Biochemistry

    Cite this

    An experimental study on fabricating an inverted mesa-type quartz crystal resonator using a cheap wet etching process. / Liang, Jinxing; Huang, Jia; Zhang, Tian; Zhang, Jing; Li, Xuefeng; Ueda, Toshitsugu.

    In: Sensors (Switzerland), Vol. 13, No. 9, 10.09.2013, p. 12140-12148.

    Research output: Contribution to journalArticle

    Liang, Jinxing ; Huang, Jia ; Zhang, Tian ; Zhang, Jing ; Li, Xuefeng ; Ueda, Toshitsugu. / An experimental study on fabricating an inverted mesa-type quartz crystal resonator using a cheap wet etching process. In: Sensors (Switzerland). 2013 ; Vol. 13, No. 9. pp. 12140-12148.
    @article{5d10772fa203439b947421434c6f2ee0,
    title = "An experimental study on fabricating an inverted mesa-type quartz crystal resonator using a cheap wet etching process",
    abstract = "In this study, a miniaturized high fundamental frequency quartz crystal microbalance (QCM) is fabricated for sensor applications using a wet etching technique. The vibration area is reduced in the fabrication of the high frequency QCM with an inverted mesa structure. To reduce the complexity of the side wall profile that results from anisotropic quartz etching, a rectangular vibration area is used instead of the conventional circular structure. QCMs with high Q values exceeding 25,000 at 47 MHz, 27,000 at 60 MHz, 24,000 at 73 MHz and 25,000 at 84 MHz are fabricated on 4 × 4 mm2chips with small vibration areas of 1.2 × 1.4 mm2. A PMMA-based flow cell is designed and manufactured to characterize the behavior of the fabricated QCM chip in a liquid. Q values as high as 1,006 at 47 MHz, 904 at 62 MHz, 867 at 71 MHz and 747 at 84 MHz are obtained when one side of the chip is exposed to pure water. These results show that fabricated QCM chips can be used for bio- and chemical sensor applications in liquids.",
    keywords = "High, High fundamental frequency, Quartz crystal microbalance, Rectangle, Value, Wet etching process",
    author = "Jinxing Liang and Jia Huang and Tian Zhang and Jing Zhang and Xuefeng Li and Toshitsugu Ueda",
    year = "2013",
    month = "9",
    day = "10",
    doi = "10.3390/s130912140",
    language = "English",
    volume = "13",
    pages = "12140--12148",
    journal = "Sensors (Switzerland)",
    issn = "1424-3210",
    publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
    number = "9",

    }

    TY - JOUR

    T1 - An experimental study on fabricating an inverted mesa-type quartz crystal resonator using a cheap wet etching process

    AU - Liang, Jinxing

    AU - Huang, Jia

    AU - Zhang, Tian

    AU - Zhang, Jing

    AU - Li, Xuefeng

    AU - Ueda, Toshitsugu

    PY - 2013/9/10

    Y1 - 2013/9/10

    N2 - In this study, a miniaturized high fundamental frequency quartz crystal microbalance (QCM) is fabricated for sensor applications using a wet etching technique. The vibration area is reduced in the fabrication of the high frequency QCM with an inverted mesa structure. To reduce the complexity of the side wall profile that results from anisotropic quartz etching, a rectangular vibration area is used instead of the conventional circular structure. QCMs with high Q values exceeding 25,000 at 47 MHz, 27,000 at 60 MHz, 24,000 at 73 MHz and 25,000 at 84 MHz are fabricated on 4 × 4 mm2chips with small vibration areas of 1.2 × 1.4 mm2. A PMMA-based flow cell is designed and manufactured to characterize the behavior of the fabricated QCM chip in a liquid. Q values as high as 1,006 at 47 MHz, 904 at 62 MHz, 867 at 71 MHz and 747 at 84 MHz are obtained when one side of the chip is exposed to pure water. These results show that fabricated QCM chips can be used for bio- and chemical sensor applications in liquids.

    AB - In this study, a miniaturized high fundamental frequency quartz crystal microbalance (QCM) is fabricated for sensor applications using a wet etching technique. The vibration area is reduced in the fabrication of the high frequency QCM with an inverted mesa structure. To reduce the complexity of the side wall profile that results from anisotropic quartz etching, a rectangular vibration area is used instead of the conventional circular structure. QCMs with high Q values exceeding 25,000 at 47 MHz, 27,000 at 60 MHz, 24,000 at 73 MHz and 25,000 at 84 MHz are fabricated on 4 × 4 mm2chips with small vibration areas of 1.2 × 1.4 mm2. A PMMA-based flow cell is designed and manufactured to characterize the behavior of the fabricated QCM chip in a liquid. Q values as high as 1,006 at 47 MHz, 904 at 62 MHz, 867 at 71 MHz and 747 at 84 MHz are obtained when one side of the chip is exposed to pure water. These results show that fabricated QCM chips can be used for bio- and chemical sensor applications in liquids.

    KW - High

    KW - High fundamental frequency

    KW - Quartz crystal microbalance

    KW - Rectangle

    KW - Value

    KW - Wet etching process

    UR - http://www.scopus.com/inward/record.url?scp=84884401349&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84884401349&partnerID=8YFLogxK

    U2 - 10.3390/s130912140

    DO - 10.3390/s130912140

    M3 - Article

    AN - SCOPUS:84884401349

    VL - 13

    SP - 12140

    EP - 12148

    JO - Sensors (Switzerland)

    JF - Sensors (Switzerland)

    SN - 1424-3210

    IS - 9

    ER -