Analysis of the energy consumption rate of office buildings by the type of heat source equipments: Analysis on 2009 fiscal year of DECC survey data

Yorimasa Iki, Satoshi Sudo, Hiroshi Yoshino, Shuzo Murakami, Kazuaki Bogaki, Katashi Matunawa, Shigeki Kametani, Hiroto Takaguchi, Hisashi Hanzawa, Masaya Okumiya, Yoshiharu Asano, Yoshiyuki Shimoda, Saburo Murakawa, Hirotoshi Yoda

    Research output: Contribution to journalArticle

    Abstract

    In this study, we aimed to confirm whether it is possible to improve the accuracy of the estimation equations of energy consumption rate of office buildings. By the difference in the type of heat source equipment, we classified the DECC survey data of 2009 fiscal year into three categories: "the electrical type", "the fuel-based type with boiler" and "the fuel-based type without boiler". As a result, using the multiple regression analysis, we were able to obtain more accurate estimation equations than before except for summer fluctuation-load rate in the electrical type.

    Original languageEnglish
    Pages (from-to)1017-1022
    Number of pages6
    JournalAIJ Journal of Technology and Design
    Volume19
    Issue number43
    DOIs
    Publication statusPublished - 2013 Oct

    Fingerprint

    Office buildings
    Boilers
    Energy utilization
    Regression analysis
    Hot Temperature

    Keywords

    • Base-load rate
    • Fluctuation-load rate
    • Heat source equipments
    • Multiple regression analysis
    • Office buildings

    ASJC Scopus subject areas

    • Building and Construction
    • Architecture

    Cite this

    Analysis of the energy consumption rate of office buildings by the type of heat source equipments : Analysis on 2009 fiscal year of DECC survey data. / Iki, Yorimasa; Sudo, Satoshi; Yoshino, Hiroshi; Murakami, Shuzo; Bogaki, Kazuaki; Matunawa, Katashi; Kametani, Shigeki; Takaguchi, Hiroto; Hanzawa, Hisashi; Okumiya, Masaya; Asano, Yoshiharu; Shimoda, Yoshiyuki; Murakawa, Saburo; Yoda, Hirotoshi.

    In: AIJ Journal of Technology and Design, Vol. 19, No. 43, 10.2013, p. 1017-1022.

    Research output: Contribution to journalArticle

    Iki, Y, Sudo, S, Yoshino, H, Murakami, S, Bogaki, K, Matunawa, K, Kametani, S, Takaguchi, H, Hanzawa, H, Okumiya, M, Asano, Y, Shimoda, Y, Murakawa, S & Yoda, H 2013, 'Analysis of the energy consumption rate of office buildings by the type of heat source equipments: Analysis on 2009 fiscal year of DECC survey data', AIJ Journal of Technology and Design, vol. 19, no. 43, pp. 1017-1022. https://doi.org/10.3130/aijt.19.1017
    Iki, Yorimasa ; Sudo, Satoshi ; Yoshino, Hiroshi ; Murakami, Shuzo ; Bogaki, Kazuaki ; Matunawa, Katashi ; Kametani, Shigeki ; Takaguchi, Hiroto ; Hanzawa, Hisashi ; Okumiya, Masaya ; Asano, Yoshiharu ; Shimoda, Yoshiyuki ; Murakawa, Saburo ; Yoda, Hirotoshi. / Analysis of the energy consumption rate of office buildings by the type of heat source equipments : Analysis on 2009 fiscal year of DECC survey data. In: AIJ Journal of Technology and Design. 2013 ; Vol. 19, No. 43. pp. 1017-1022.
    @article{a49b185012224f519296caa3beb836d4,
    title = "Analysis of the energy consumption rate of office buildings by the type of heat source equipments: Analysis on 2009 fiscal year of DECC survey data",
    abstract = "In this study, we aimed to confirm whether it is possible to improve the accuracy of the estimation equations of energy consumption rate of office buildings. By the difference in the type of heat source equipment, we classified the DECC survey data of 2009 fiscal year into three categories: {"}the electrical type{"}, {"}the fuel-based type with boiler{"} and {"}the fuel-based type without boiler{"}. As a result, using the multiple regression analysis, we were able to obtain more accurate estimation equations than before except for summer fluctuation-load rate in the electrical type.",
    keywords = "Base-load rate, Fluctuation-load rate, Heat source equipments, Multiple regression analysis, Office buildings",
    author = "Yorimasa Iki and Satoshi Sudo and Hiroshi Yoshino and Shuzo Murakami and Kazuaki Bogaki and Katashi Matunawa and Shigeki Kametani and Hiroto Takaguchi and Hisashi Hanzawa and Masaya Okumiya and Yoshiharu Asano and Yoshiyuki Shimoda and Saburo Murakawa and Hirotoshi Yoda",
    year = "2013",
    month = "10",
    doi = "10.3130/aijt.19.1017",
    language = "English",
    volume = "19",
    pages = "1017--1022",
    journal = "AIJ Journal of Technology and Design",
    issn = "1341-9463",
    publisher = "Architectural Institute of Japan",
    number = "43",

    }

    TY - JOUR

    T1 - Analysis of the energy consumption rate of office buildings by the type of heat source equipments

    T2 - Analysis on 2009 fiscal year of DECC survey data

    AU - Iki, Yorimasa

    AU - Sudo, Satoshi

    AU - Yoshino, Hiroshi

    AU - Murakami, Shuzo

    AU - Bogaki, Kazuaki

    AU - Matunawa, Katashi

    AU - Kametani, Shigeki

    AU - Takaguchi, Hiroto

    AU - Hanzawa, Hisashi

    AU - Okumiya, Masaya

    AU - Asano, Yoshiharu

    AU - Shimoda, Yoshiyuki

    AU - Murakawa, Saburo

    AU - Yoda, Hirotoshi

    PY - 2013/10

    Y1 - 2013/10

    N2 - In this study, we aimed to confirm whether it is possible to improve the accuracy of the estimation equations of energy consumption rate of office buildings. By the difference in the type of heat source equipment, we classified the DECC survey data of 2009 fiscal year into three categories: "the electrical type", "the fuel-based type with boiler" and "the fuel-based type without boiler". As a result, using the multiple regression analysis, we were able to obtain more accurate estimation equations than before except for summer fluctuation-load rate in the electrical type.

    AB - In this study, we aimed to confirm whether it is possible to improve the accuracy of the estimation equations of energy consumption rate of office buildings. By the difference in the type of heat source equipment, we classified the DECC survey data of 2009 fiscal year into three categories: "the electrical type", "the fuel-based type with boiler" and "the fuel-based type without boiler". As a result, using the multiple regression analysis, we were able to obtain more accurate estimation equations than before except for summer fluctuation-load rate in the electrical type.

    KW - Base-load rate

    KW - Fluctuation-load rate

    KW - Heat source equipments

    KW - Multiple regression analysis

    KW - Office buildings

    UR - http://www.scopus.com/inward/record.url?scp=84891509085&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84891509085&partnerID=8YFLogxK

    U2 - 10.3130/aijt.19.1017

    DO - 10.3130/aijt.19.1017

    M3 - Article

    AN - SCOPUS:84891509085

    VL - 19

    SP - 1017

    EP - 1022

    JO - AIJ Journal of Technology and Design

    JF - AIJ Journal of Technology and Design

    SN - 1341-9463

    IS - 43

    ER -