Association between contraction-induced increases in elbow flexor muscle thickness and distal biceps brachii tendon moment arm depends on the muscle thickness measurement site

Ryota Akagi, Soichiro Iwanuma, Satoru Hashizume, Hiroaki Kanehisa, Toshimasa Yanai, Yasuo Kawakami

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The purpose of this study was to investigate how the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness, with a specific emphasis on the influence of the site-related differences in muscle thickness. The moment arm and muscle thickness were determined from sagittal and cross-sectional images, respectively, of the right arm obtained by magnetic resonance imaging of nine young men. The muscle thickness was measured at levels from the reference site (60% of the upper arm length from the acromial process of the scapula to the lateral epicondyle of the humerus) to 60 mm distal to it (every 10 mm; 7 measurement sites). At 80° of elbow flexion, the moment arm and muscle thickness were determined at rest and during 60% of maximal voluntary contraction (60%MVC) of isometric elbow flexion. Only the relative change from rest to 60%MVC in muscle thickness at the level 60 mm distal to the reference site correlated significantly with that of the moment arm. This result indicates that the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness near the corresponding muscle-tendon junction.

Original languageEnglish
Pages (from-to)134-139
Number of pages6
JournalJournal of Applied Biomechanics
Volume30
Issue number1
DOIs
Publication statusPublished - 2014

Fingerprint

Elbow
Tendons
Muscles
Arm
Scapula
Isometric Contraction
Humerus
Muscle Contraction
Magnetic Resonance Imaging

Keywords

  • Center of rotation method
  • Magnetic resonance imaging
  • Submaximal isometric contraction

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Biophysics
  • Rehabilitation

Cite this

Association between contraction-induced increases in elbow flexor muscle thickness and distal biceps brachii tendon moment arm depends on the muscle thickness measurement site. / Akagi, Ryota; Iwanuma, Soichiro; Hashizume, Satoru; Kanehisa, Hiroaki; Yanai, Toshimasa; Kawakami, Yasuo.

In: Journal of Applied Biomechanics, Vol. 30, No. 1, 2014, p. 134-139.

Research output: Contribution to journalArticle

@article{3b9a510fd67242f5b53e3a395bcf112d,
title = "Association between contraction-induced increases in elbow flexor muscle thickness and distal biceps brachii tendon moment arm depends on the muscle thickness measurement site",
abstract = "The purpose of this study was to investigate how the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness, with a specific emphasis on the influence of the site-related differences in muscle thickness. The moment arm and muscle thickness were determined from sagittal and cross-sectional images, respectively, of the right arm obtained by magnetic resonance imaging of nine young men. The muscle thickness was measured at levels from the reference site (60{\%} of the upper arm length from the acromial process of the scapula to the lateral epicondyle of the humerus) to 60 mm distal to it (every 10 mm; 7 measurement sites). At 80° of elbow flexion, the moment arm and muscle thickness were determined at rest and during 60{\%} of maximal voluntary contraction (60{\%}MVC) of isometric elbow flexion. Only the relative change from rest to 60{\%}MVC in muscle thickness at the level 60 mm distal to the reference site correlated significantly with that of the moment arm. This result indicates that the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness near the corresponding muscle-tendon junction.",
keywords = "Center of rotation method, Magnetic resonance imaging, Submaximal isometric contraction",
author = "Ryota Akagi and Soichiro Iwanuma and Satoru Hashizume and Hiroaki Kanehisa and Toshimasa Yanai and Yasuo Kawakami",
year = "2014",
doi = "10.1123/jab.2012-0145",
language = "English",
volume = "30",
pages = "134--139",
journal = "Journal of Applied Biomechanics",
issn = "1065-8483",
publisher = "Human Kinetics Publishers Inc.",
number = "1",

}

TY - JOUR

T1 - Association between contraction-induced increases in elbow flexor muscle thickness and distal biceps brachii tendon moment arm depends on the muscle thickness measurement site

AU - Akagi, Ryota

AU - Iwanuma, Soichiro

AU - Hashizume, Satoru

AU - Kanehisa, Hiroaki

AU - Yanai, Toshimasa

AU - Kawakami, Yasuo

PY - 2014

Y1 - 2014

N2 - The purpose of this study was to investigate how the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness, with a specific emphasis on the influence of the site-related differences in muscle thickness. The moment arm and muscle thickness were determined from sagittal and cross-sectional images, respectively, of the right arm obtained by magnetic resonance imaging of nine young men. The muscle thickness was measured at levels from the reference site (60% of the upper arm length from the acromial process of the scapula to the lateral epicondyle of the humerus) to 60 mm distal to it (every 10 mm; 7 measurement sites). At 80° of elbow flexion, the moment arm and muscle thickness were determined at rest and during 60% of maximal voluntary contraction (60%MVC) of isometric elbow flexion. Only the relative change from rest to 60%MVC in muscle thickness at the level 60 mm distal to the reference site correlated significantly with that of the moment arm. This result indicates that the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness near the corresponding muscle-tendon junction.

AB - The purpose of this study was to investigate how the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness, with a specific emphasis on the influence of the site-related differences in muscle thickness. The moment arm and muscle thickness were determined from sagittal and cross-sectional images, respectively, of the right arm obtained by magnetic resonance imaging of nine young men. The muscle thickness was measured at levels from the reference site (60% of the upper arm length from the acromial process of the scapula to the lateral epicondyle of the humerus) to 60 mm distal to it (every 10 mm; 7 measurement sites). At 80° of elbow flexion, the moment arm and muscle thickness were determined at rest and during 60% of maximal voluntary contraction (60%MVC) of isometric elbow flexion. Only the relative change from rest to 60%MVC in muscle thickness at the level 60 mm distal to the reference site correlated significantly with that of the moment arm. This result indicates that the contraction-induced increase in distal biceps brachii tendon moment arm is related to that in elbow flexor muscle thickness near the corresponding muscle-tendon junction.

KW - Center of rotation method

KW - Magnetic resonance imaging

KW - Submaximal isometric contraction

UR - http://www.scopus.com/inward/record.url?scp=84897411182&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84897411182&partnerID=8YFLogxK

U2 - 10.1123/jab.2012-0145

DO - 10.1123/jab.2012-0145

M3 - Article

C2 - 24676520

AN - SCOPUS:84897411182

VL - 30

SP - 134

EP - 139

JO - Journal of Applied Biomechanics

JF - Journal of Applied Biomechanics

SN - 1065-8483

IS - 1

ER -