Automatic laser scanning ablation system for high-precision treatment of brain tumors

Hongen Liao, Keisuke Fujiwara, Takehiro Ando, Takashi Maruyama, Etsuko Kobayashi, Yoshihiro Muragaki, Hiroshi Iseki, Ichiro Sakuma

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

Complete removal of malignant gliomas is important for the prognosis in neurosurgery treatment. Currently, the challenge is how to detect any remaining tumors and resect them during the operation. We have developed a laser ablation system with accurate tumor analysis and fluorescence guidance for high-precision brain tumor resection during neurosurgery. A 5-aminolevulinic acid-induced fluorescent protoporphyrins IX (PpIX)-based intra-operative fluorescence measurement and corresponding spectra analysis technique is used to identify the position of tumors. A galvano mirror scanning mechanism is integrated into the fluorescence measurement and the laser ablation devices for automatic tumor area scanning and corresponding laser ablation. A set of phantom experiments was performed to evaluate the proposed system. Results showed that the galvano scanning mechanism enabled both PpIX fluorescence detection and laser ablation in the same optical axis. In vitro experiments using porcine brain were performed to evaluate the effectiveness of the automatic laser scanning, fluorescence detection, and laser ablation system. The proposed fluorescence-guided laser ablation system can provide accurate analysis and high-precision treatment for tumor resection in neurosurgery. With further improvement, the system can be used in neurosurgical implementation to provide accurate, safe, and simple surgical diagnosis and therapy.

Original languageEnglish
Pages (from-to)891-900
Number of pages10
JournalLasers in Medical Science
Volume28
Issue number3
DOIs
Publication statusPublished - 2013 May
Externally publishedYes

Fingerprint

Laser Therapy
Brain Neoplasms
Fluorescence
Neurosurgery
Neoplasms
Therapeutics
Aminolevulinic Acid
Glioma
Spectrum Analysis
Lasers
Swine
Equipment and Supplies
Brain

Keywords

  • 5-aminolevulinic-acid
  • Fluorescence
  • Laser ablation
  • Neurosurgery
  • Spectra analysis

ASJC Scopus subject areas

  • Surgery
  • Dermatology

Cite this

Liao, H., Fujiwara, K., Ando, T., Maruyama, T., Kobayashi, E., Muragaki, Y., ... Sakuma, I. (2013). Automatic laser scanning ablation system for high-precision treatment of brain tumors. Lasers in Medical Science, 28(3), 891-900. https://doi.org/10.1007/s10103-012-1164-6

Automatic laser scanning ablation system for high-precision treatment of brain tumors. / Liao, Hongen; Fujiwara, Keisuke; Ando, Takehiro; Maruyama, Takashi; Kobayashi, Etsuko; Muragaki, Yoshihiro; Iseki, Hiroshi; Sakuma, Ichiro.

In: Lasers in Medical Science, Vol. 28, No. 3, 05.2013, p. 891-900.

Research output: Contribution to journalArticle

Liao, H, Fujiwara, K, Ando, T, Maruyama, T, Kobayashi, E, Muragaki, Y, Iseki, H & Sakuma, I 2013, 'Automatic laser scanning ablation system for high-precision treatment of brain tumors', Lasers in Medical Science, vol. 28, no. 3, pp. 891-900. https://doi.org/10.1007/s10103-012-1164-6
Liao, Hongen ; Fujiwara, Keisuke ; Ando, Takehiro ; Maruyama, Takashi ; Kobayashi, Etsuko ; Muragaki, Yoshihiro ; Iseki, Hiroshi ; Sakuma, Ichiro. / Automatic laser scanning ablation system for high-precision treatment of brain tumors. In: Lasers in Medical Science. 2013 ; Vol. 28, No. 3. pp. 891-900.
@article{90b06ca57dcf463a866f24044b70c020,
title = "Automatic laser scanning ablation system for high-precision treatment of brain tumors",
abstract = "Complete removal of malignant gliomas is important for the prognosis in neurosurgery treatment. Currently, the challenge is how to detect any remaining tumors and resect them during the operation. We have developed a laser ablation system with accurate tumor analysis and fluorescence guidance for high-precision brain tumor resection during neurosurgery. A 5-aminolevulinic acid-induced fluorescent protoporphyrins IX (PpIX)-based intra-operative fluorescence measurement and corresponding spectra analysis technique is used to identify the position of tumors. A galvano mirror scanning mechanism is integrated into the fluorescence measurement and the laser ablation devices for automatic tumor area scanning and corresponding laser ablation. A set of phantom experiments was performed to evaluate the proposed system. Results showed that the galvano scanning mechanism enabled both PpIX fluorescence detection and laser ablation in the same optical axis. In vitro experiments using porcine brain were performed to evaluate the effectiveness of the automatic laser scanning, fluorescence detection, and laser ablation system. The proposed fluorescence-guided laser ablation system can provide accurate analysis and high-precision treatment for tumor resection in neurosurgery. With further improvement, the system can be used in neurosurgical implementation to provide accurate, safe, and simple surgical diagnosis and therapy.",
keywords = "5-aminolevulinic-acid, Fluorescence, Laser ablation, Neurosurgery, Spectra analysis",
author = "Hongen Liao and Keisuke Fujiwara and Takehiro Ando and Takashi Maruyama and Etsuko Kobayashi and Yoshihiro Muragaki and Hiroshi Iseki and Ichiro Sakuma",
year = "2013",
month = "5",
doi = "10.1007/s10103-012-1164-6",
language = "English",
volume = "28",
pages = "891--900",
journal = "Lasers in Medical Science",
issn = "0268-8921",
publisher = "Springer London",
number = "3",

}

TY - JOUR

T1 - Automatic laser scanning ablation system for high-precision treatment of brain tumors

AU - Liao, Hongen

AU - Fujiwara, Keisuke

AU - Ando, Takehiro

AU - Maruyama, Takashi

AU - Kobayashi, Etsuko

AU - Muragaki, Yoshihiro

AU - Iseki, Hiroshi

AU - Sakuma, Ichiro

PY - 2013/5

Y1 - 2013/5

N2 - Complete removal of malignant gliomas is important for the prognosis in neurosurgery treatment. Currently, the challenge is how to detect any remaining tumors and resect them during the operation. We have developed a laser ablation system with accurate tumor analysis and fluorescence guidance for high-precision brain tumor resection during neurosurgery. A 5-aminolevulinic acid-induced fluorescent protoporphyrins IX (PpIX)-based intra-operative fluorescence measurement and corresponding spectra analysis technique is used to identify the position of tumors. A galvano mirror scanning mechanism is integrated into the fluorescence measurement and the laser ablation devices for automatic tumor area scanning and corresponding laser ablation. A set of phantom experiments was performed to evaluate the proposed system. Results showed that the galvano scanning mechanism enabled both PpIX fluorescence detection and laser ablation in the same optical axis. In vitro experiments using porcine brain were performed to evaluate the effectiveness of the automatic laser scanning, fluorescence detection, and laser ablation system. The proposed fluorescence-guided laser ablation system can provide accurate analysis and high-precision treatment for tumor resection in neurosurgery. With further improvement, the system can be used in neurosurgical implementation to provide accurate, safe, and simple surgical diagnosis and therapy.

AB - Complete removal of malignant gliomas is important for the prognosis in neurosurgery treatment. Currently, the challenge is how to detect any remaining tumors and resect them during the operation. We have developed a laser ablation system with accurate tumor analysis and fluorescence guidance for high-precision brain tumor resection during neurosurgery. A 5-aminolevulinic acid-induced fluorescent protoporphyrins IX (PpIX)-based intra-operative fluorescence measurement and corresponding spectra analysis technique is used to identify the position of tumors. A galvano mirror scanning mechanism is integrated into the fluorescence measurement and the laser ablation devices for automatic tumor area scanning and corresponding laser ablation. A set of phantom experiments was performed to evaluate the proposed system. Results showed that the galvano scanning mechanism enabled both PpIX fluorescence detection and laser ablation in the same optical axis. In vitro experiments using porcine brain were performed to evaluate the effectiveness of the automatic laser scanning, fluorescence detection, and laser ablation system. The proposed fluorescence-guided laser ablation system can provide accurate analysis and high-precision treatment for tumor resection in neurosurgery. With further improvement, the system can be used in neurosurgical implementation to provide accurate, safe, and simple surgical diagnosis and therapy.

KW - 5-aminolevulinic-acid

KW - Fluorescence

KW - Laser ablation

KW - Neurosurgery

KW - Spectra analysis

UR - http://www.scopus.com/inward/record.url?scp=84880722736&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880722736&partnerID=8YFLogxK

U2 - 10.1007/s10103-012-1164-6

DO - 10.1007/s10103-012-1164-6

M3 - Article

VL - 28

SP - 891

EP - 900

JO - Lasers in Medical Science

JF - Lasers in Medical Science

SN - 0268-8921

IS - 3

ER -