N2 - The characteristics of a detector fabricated using piezoelectric lead zirconate titanate (PZT) were studied by irradiating it with a 400 MeV/n xenon (Xe) beam while changing the beam flux intensity. The largest output signal was observed from the detector when the beam power per unit time was estimated to be largest. It was also found that the sensitivity per Xe ion of the detector seemed to be higher with decreasing the amount of the Xe ion flux within the limits of the experimental conditions.
AB - The characteristics of a detector fabricated using piezoelectric lead zirconate titanate (PZT) were studied by irradiating it with a 400 MeV/n xenon (Xe) beam while changing the beam flux intensity. The largest output signal was observed from the detector when the beam power per unit time was estimated to be largest. It was also found that the sensitivity per Xe ion of the detector seemed to be higher with decreasing the amount of the Xe ion flux within the limits of the experimental conditions.
KW - Heavy-ion detector
KW - Lead zirconate titanate (PZT)
KW - Piezoelectricity
UR - http://www.scopus.com/inward/record.url?scp=71749100441&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=71749100441&partnerID=8YFLogxK
U2 - 10.1016/j.nima.2009.08.046
DO - 10.1016/j.nima.2009.08.046
M3 - Article
AN - SCOPUS:71749100441
VL - 609
SP - 272
EP - 275
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
SN - 0168-9002
IS - 2-3
ER -