Change of pH of inside the crevice with time during crevice corrosion initiation and growth step of a duplex stainless steel

Nobuaki Ito, Ryotaro Yamamoto, Jun'ichi Sakai

    Research output: Contribution to journalArticle

    1 Citation (Scopus)

    Abstract

    The objective in this study was to clarify the change of pH with time inside crevice in potentiostatic crevice corrosion test. Sensing plate to discoloration by the change of pH was made. The crevice corrosion of a duplex stainless steel in potentiostatic crevice corrosion test using a sensing plate was in situ observation. The change of pH with time inside crevice was measured by discoloration of the coating agent of the sensing plate. Crevice corrosion of duplex stainless steel occurred at the point where pH is lowered locally. And, it was found that pH of crevice corrosion tip was below the depassivation pH of both phases.

    Original languageEnglish
    Pages (from-to)193-196
    Number of pages4
    JournalZairyo to Kankyo/ Corrosion Engineering
    Volume64
    Issue number5
    Publication statusPublished - 2015

    Fingerprint

    Stainless Steel
    Stainless steel
    Corrosion
    Discoloration
    Coatings

    Keywords

    • Crevice corrosion
    • Depassivation
    • Duplex stainless steel
    • Growth
    • In-situ observation
    • Initiation
    • PH

    ASJC Scopus subject areas

    • Electrochemistry
    • Materials Chemistry
    • Metals and Alloys
    • Surfaces, Coatings and Films

    Cite this

    Change of pH of inside the crevice with time during crevice corrosion initiation and growth step of a duplex stainless steel. / Ito, Nobuaki; Yamamoto, Ryotaro; Sakai, Jun'ichi.

    In: Zairyo to Kankyo/ Corrosion Engineering, Vol. 64, No. 5, 2015, p. 193-196.

    Research output: Contribution to journalArticle

    @article{7ccfcacf01954ffe991fe8d5a15a0fd4,
    title = "Change of pH of inside the crevice with time during crevice corrosion initiation and growth step of a duplex stainless steel",
    abstract = "The objective in this study was to clarify the change of pH with time inside crevice in potentiostatic crevice corrosion test. Sensing plate to discoloration by the change of pH was made. The crevice corrosion of a duplex stainless steel in potentiostatic crevice corrosion test using a sensing plate was in situ observation. The change of pH with time inside crevice was measured by discoloration of the coating agent of the sensing plate. Crevice corrosion of duplex stainless steel occurred at the point where pH is lowered locally. And, it was found that pH of crevice corrosion tip was below the depassivation pH of both phases.",
    keywords = "Crevice corrosion, Depassivation, Duplex stainless steel, Growth, In-situ observation, Initiation, PH",
    author = "Nobuaki Ito and Ryotaro Yamamoto and Jun'ichi Sakai",
    year = "2015",
    language = "English",
    volume = "64",
    pages = "193--196",
    journal = "Corrosion Engineering",
    issn = "0917-0480",
    publisher = "Japan Society of Corrosion Engineering",
    number = "5",

    }

    TY - JOUR

    T1 - Change of pH of inside the crevice with time during crevice corrosion initiation and growth step of a duplex stainless steel

    AU - Ito, Nobuaki

    AU - Yamamoto, Ryotaro

    AU - Sakai, Jun'ichi

    PY - 2015

    Y1 - 2015

    N2 - The objective in this study was to clarify the change of pH with time inside crevice in potentiostatic crevice corrosion test. Sensing plate to discoloration by the change of pH was made. The crevice corrosion of a duplex stainless steel in potentiostatic crevice corrosion test using a sensing plate was in situ observation. The change of pH with time inside crevice was measured by discoloration of the coating agent of the sensing plate. Crevice corrosion of duplex stainless steel occurred at the point where pH is lowered locally. And, it was found that pH of crevice corrosion tip was below the depassivation pH of both phases.

    AB - The objective in this study was to clarify the change of pH with time inside crevice in potentiostatic crevice corrosion test. Sensing plate to discoloration by the change of pH was made. The crevice corrosion of a duplex stainless steel in potentiostatic crevice corrosion test using a sensing plate was in situ observation. The change of pH with time inside crevice was measured by discoloration of the coating agent of the sensing plate. Crevice corrosion of duplex stainless steel occurred at the point where pH is lowered locally. And, it was found that pH of crevice corrosion tip was below the depassivation pH of both phases.

    KW - Crevice corrosion

    KW - Depassivation

    KW - Duplex stainless steel

    KW - Growth

    KW - In-situ observation

    KW - Initiation

    KW - PH

    UR - http://www.scopus.com/inward/record.url?scp=84947072478&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84947072478&partnerID=8YFLogxK

    M3 - Article

    VL - 64

    SP - 193

    EP - 196

    JO - Corrosion Engineering

    JF - Corrosion Engineering

    SN - 0917-0480

    IS - 5

    ER -