Comparative atomic force and scanning electron microscopy for fine structural images of nerve cells

Takuro Tojima, Dai Hatakeyama, Yukako Yamane, Kazushige Kawabata, Tatsuo Ushiki, Shigeaki Ogura, Kazuhiro Abe, Etsuro Ito

Research output: Contribution to journalArticle

23 Citations (Scopus)

Abstract

Although we can routinely obtain fine structural images of cells by atomic force microscopy (AFM), the adequacy and reliability of morphological information acquired from these AFM images remain to be examined. In this report, we compared images of the fine structures of nerve cells as observed by both AFM and scanning electron microscopy (SEM). Although AFM revealed the structure of the top views of cells in greater detail than SEM, their side structures were better observed by SEM. The linear structures in the neural processes detected only by AFM were confirmed, by immunofluorescence staining, to be reflections of the cytoskeletal structures located beneath the cell membrane. These differences between the AFM and the SEM images reflected the characteristics of the detection systems and methods used for sample preparation. Therefore, these results revealed that more detailed information on cell morphology can be obtained by using both AFM and SEM to advantage.

Original languageEnglish
Pages (from-to)3855-3859
Number of pages5
JournalJapanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers
Volume37
Issue number6 SUPPL. B
Publication statusPublished - 1998 Jun
Externally publishedYes

Fingerprint

nerves
Neurons
Atomic force microscopy
atomic force microscopy
Scanning electron microscopy
scanning electron microscopy
cells
adequacy
staining
Cell membranes
fine structure
preparation

Keywords

  • Actin filament
  • Cytoskeleton
  • Fixation
  • Immunofluorescence staining
  • Metal coating
  • Microtubule
  • NG108-15
  • Scanning electron microscopy

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)
  • Engineering(all)

Cite this

Comparative atomic force and scanning electron microscopy for fine structural images of nerve cells. / Tojima, Takuro; Hatakeyama, Dai; Yamane, Yukako; Kawabata, Kazushige; Ushiki, Tatsuo; Ogura, Shigeaki; Abe, Kazuhiro; Ito, Etsuro.

In: Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, Vol. 37, No. 6 SUPPL. B, 06.1998, p. 3855-3859.

Research output: Contribution to journalArticle

Tojima, Takuro ; Hatakeyama, Dai ; Yamane, Yukako ; Kawabata, Kazushige ; Ushiki, Tatsuo ; Ogura, Shigeaki ; Abe, Kazuhiro ; Ito, Etsuro. / Comparative atomic force and scanning electron microscopy for fine structural images of nerve cells. In: Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers. 1998 ; Vol. 37, No. 6 SUPPL. B. pp. 3855-3859.
@article{5f39b54de7994bb0932dcc723c91741e,
title = "Comparative atomic force and scanning electron microscopy for fine structural images of nerve cells",
abstract = "Although we can routinely obtain fine structural images of cells by atomic force microscopy (AFM), the adequacy and reliability of morphological information acquired from these AFM images remain to be examined. In this report, we compared images of the fine structures of nerve cells as observed by both AFM and scanning electron microscopy (SEM). Although AFM revealed the structure of the top views of cells in greater detail than SEM, their side structures were better observed by SEM. The linear structures in the neural processes detected only by AFM were confirmed, by immunofluorescence staining, to be reflections of the cytoskeletal structures located beneath the cell membrane. These differences between the AFM and the SEM images reflected the characteristics of the detection systems and methods used for sample preparation. Therefore, these results revealed that more detailed information on cell morphology can be obtained by using both AFM and SEM to advantage.",
keywords = "Actin filament, Cytoskeleton, Fixation, Immunofluorescence staining, Metal coating, Microtubule, NG108-15, Scanning electron microscopy",
author = "Takuro Tojima and Dai Hatakeyama and Yukako Yamane and Kazushige Kawabata and Tatsuo Ushiki and Shigeaki Ogura and Kazuhiro Abe and Etsuro Ito",
year = "1998",
month = "6",
language = "English",
volume = "37",
pages = "3855--3859",
journal = "Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes",
issn = "0021-4922",
publisher = "Japan Society of Applied Physics",
number = "6 SUPPL. B",

}

TY - JOUR

T1 - Comparative atomic force and scanning electron microscopy for fine structural images of nerve cells

AU - Tojima, Takuro

AU - Hatakeyama, Dai

AU - Yamane, Yukako

AU - Kawabata, Kazushige

AU - Ushiki, Tatsuo

AU - Ogura, Shigeaki

AU - Abe, Kazuhiro

AU - Ito, Etsuro

PY - 1998/6

Y1 - 1998/6

N2 - Although we can routinely obtain fine structural images of cells by atomic force microscopy (AFM), the adequacy and reliability of morphological information acquired from these AFM images remain to be examined. In this report, we compared images of the fine structures of nerve cells as observed by both AFM and scanning electron microscopy (SEM). Although AFM revealed the structure of the top views of cells in greater detail than SEM, their side structures were better observed by SEM. The linear structures in the neural processes detected only by AFM were confirmed, by immunofluorescence staining, to be reflections of the cytoskeletal structures located beneath the cell membrane. These differences between the AFM and the SEM images reflected the characteristics of the detection systems and methods used for sample preparation. Therefore, these results revealed that more detailed information on cell morphology can be obtained by using both AFM and SEM to advantage.

AB - Although we can routinely obtain fine structural images of cells by atomic force microscopy (AFM), the adequacy and reliability of morphological information acquired from these AFM images remain to be examined. In this report, we compared images of the fine structures of nerve cells as observed by both AFM and scanning electron microscopy (SEM). Although AFM revealed the structure of the top views of cells in greater detail than SEM, their side structures were better observed by SEM. The linear structures in the neural processes detected only by AFM were confirmed, by immunofluorescence staining, to be reflections of the cytoskeletal structures located beneath the cell membrane. These differences between the AFM and the SEM images reflected the characteristics of the detection systems and methods used for sample preparation. Therefore, these results revealed that more detailed information on cell morphology can be obtained by using both AFM and SEM to advantage.

KW - Actin filament

KW - Cytoskeleton

KW - Fixation

KW - Immunofluorescence staining

KW - Metal coating

KW - Microtubule

KW - NG108-15

KW - Scanning electron microscopy

UR - http://www.scopus.com/inward/record.url?scp=0032092191&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032092191&partnerID=8YFLogxK

M3 - Article

VL - 37

SP - 3855

EP - 3859

JO - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes

JF - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes

SN - 0021-4922

IS - 6 SUPPL. B

ER -