Construction of an electron analyzer with a wide acceptance solid angle

Daisuke Sakai, Daisuke Miura, Takeshi Nakajima, Tsuyoshi Ishikawa, Chuhei Oshima, Hideo Iwai, Yoshimasa Nihei

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

We have developed a new electron energy analyzer with a large solid angle of 0.14π, which is comparable to that of cylindrical mirror analyzer. Typical energy resolution was ΔE/E0 ∼ 0.016 for the aperture of 1 mm and central radius of 100 mm, and typical angular resolution was less than 0.5°.

Original languageEnglish
JournalSurface Science
Volume600
Issue number4
DOIs
Publication statusPublished - 2006 Feb 15

Fingerprint

Electron energy analyzers
acceptability
analyzers
Mirrors
Electrons
angular resolution
electrons
apertures
electron energy
mirrors
radii
energy

Keywords

  • Auger electron spectroscopy (AES)
  • Electron energy loss spectroscopy (EELS)
  • Electron spectroscopy
  • Low energy electron diffraction (LEED)

ASJC Scopus subject areas

  • Physical and Theoretical Chemistry
  • Condensed Matter Physics
  • Surfaces and Interfaces

Cite this

Sakai, D., Miura, D., Nakajima, T., Ishikawa, T., Oshima, C., Iwai, H., & Nihei, Y. (2006). Construction of an electron analyzer with a wide acceptance solid angle. Surface Science, 600(4). https://doi.org/10.1016/j.susc.2005.11.028

Construction of an electron analyzer with a wide acceptance solid angle. / Sakai, Daisuke; Miura, Daisuke; Nakajima, Takeshi; Ishikawa, Tsuyoshi; Oshima, Chuhei; Iwai, Hideo; Nihei, Yoshimasa.

In: Surface Science, Vol. 600, No. 4, 15.02.2006.

Research output: Contribution to journalArticle

Sakai, D, Miura, D, Nakajima, T, Ishikawa, T, Oshima, C, Iwai, H & Nihei, Y 2006, 'Construction of an electron analyzer with a wide acceptance solid angle', Surface Science, vol. 600, no. 4. https://doi.org/10.1016/j.susc.2005.11.028
Sakai D, Miura D, Nakajima T, Ishikawa T, Oshima C, Iwai H et al. Construction of an electron analyzer with a wide acceptance solid angle. Surface Science. 2006 Feb 15;600(4). https://doi.org/10.1016/j.susc.2005.11.028
Sakai, Daisuke ; Miura, Daisuke ; Nakajima, Takeshi ; Ishikawa, Tsuyoshi ; Oshima, Chuhei ; Iwai, Hideo ; Nihei, Yoshimasa. / Construction of an electron analyzer with a wide acceptance solid angle. In: Surface Science. 2006 ; Vol. 600, No. 4.
@article{d8a8f6ad7c60450e907b639de58a9024,
title = "Construction of an electron analyzer with a wide acceptance solid angle",
abstract = "We have developed a new electron energy analyzer with a large solid angle of 0.14π, which is comparable to that of cylindrical mirror analyzer. Typical energy resolution was ΔE/E0 ∼ 0.016 for the aperture of 1 mm and central radius of 100 mm, and typical angular resolution was less than 0.5°.",
keywords = "Auger electron spectroscopy (AES), Electron energy loss spectroscopy (EELS), Electron spectroscopy, Low energy electron diffraction (LEED)",
author = "Daisuke Sakai and Daisuke Miura and Takeshi Nakajima and Tsuyoshi Ishikawa and Chuhei Oshima and Hideo Iwai and Yoshimasa Nihei",
year = "2006",
month = "2",
day = "15",
doi = "10.1016/j.susc.2005.11.028",
language = "English",
volume = "600",
journal = "Surface Science",
issn = "0039-6028",
publisher = "Elsevier",
number = "4",

}

TY - JOUR

T1 - Construction of an electron analyzer with a wide acceptance solid angle

AU - Sakai, Daisuke

AU - Miura, Daisuke

AU - Nakajima, Takeshi

AU - Ishikawa, Tsuyoshi

AU - Oshima, Chuhei

AU - Iwai, Hideo

AU - Nihei, Yoshimasa

PY - 2006/2/15

Y1 - 2006/2/15

N2 - We have developed a new electron energy analyzer with a large solid angle of 0.14π, which is comparable to that of cylindrical mirror analyzer. Typical energy resolution was ΔE/E0 ∼ 0.016 for the aperture of 1 mm and central radius of 100 mm, and typical angular resolution was less than 0.5°.

AB - We have developed a new electron energy analyzer with a large solid angle of 0.14π, which is comparable to that of cylindrical mirror analyzer. Typical energy resolution was ΔE/E0 ∼ 0.016 for the aperture of 1 mm and central radius of 100 mm, and typical angular resolution was less than 0.5°.

KW - Auger electron spectroscopy (AES)

KW - Electron energy loss spectroscopy (EELS)

KW - Electron spectroscopy

KW - Low energy electron diffraction (LEED)

UR - http://www.scopus.com/inward/record.url?scp=32444433808&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=32444433808&partnerID=8YFLogxK

U2 - 10.1016/j.susc.2005.11.028

DO - 10.1016/j.susc.2005.11.028

M3 - Article

AN - SCOPUS:32444433808

VL - 600

JO - Surface Science

JF - Surface Science

SN - 0039-6028

IS - 4

ER -