Continuous operation control of PMSM with compressor loads of air conditioners in case of DC power supply loss

Jongwon Heo, Kentaro Matsuo, Kenji Natori, Keiichiro Kondo

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The interruption of power supply is one of the major technical issues in rotation angle sensorless controls of PMSMs. This causes failures of inverter operation due to voltage drop in filter capacitor (FC). In order to solve this technical issue, we propose a method to achieve continuous operation of PMSMs with low inertia loads, for example compressors of air conditioners, in case of power supply interruption. In the proposed method, the current reference is determined according to the relationship between the kinetic energy of the motor and the electrical energy of the FC to effectively use the available energy. The proposed method is validated by experimental test of 1-kW class PMSM.

Original languageEnglish
Pages (from-to)687-695
Number of pages9
JournalIEEJ Transactions on Industry Applications
Volume137
Issue number9
DOIs
Publication statusPublished - 2017 Jan 1
Externally publishedYes

Fingerprint

Compressors
Capacitors
Air
Kinetic energy
Voltage drop
Sensorless control

Keywords

  • Continued operation
  • Low inertial loads
  • PMSM
  • Power supply loss
  • Sensorless control

ASJC Scopus subject areas

  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Cite this

Continuous operation control of PMSM with compressor loads of air conditioners in case of DC power supply loss. / Heo, Jongwon; Matsuo, Kentaro; Natori, Kenji; Kondo, Keiichiro.

In: IEEJ Transactions on Industry Applications, Vol. 137, No. 9, 01.01.2017, p. 687-695.

Research output: Contribution to journalArticle

@article{0b734b08008041859e28d30e330a1702,
title = "Continuous operation control of PMSM with compressor loads of air conditioners in case of DC power supply loss",
abstract = "The interruption of power supply is one of the major technical issues in rotation angle sensorless controls of PMSMs. This causes failures of inverter operation due to voltage drop in filter capacitor (FC). In order to solve this technical issue, we propose a method to achieve continuous operation of PMSMs with low inertia loads, for example compressors of air conditioners, in case of power supply interruption. In the proposed method, the current reference is determined according to the relationship between the kinetic energy of the motor and the electrical energy of the FC to effectively use the available energy. The proposed method is validated by experimental test of 1-kW class PMSM.",
keywords = "Continued operation, Low inertial loads, PMSM, Power supply loss, Sensorless control",
author = "Jongwon Heo and Kentaro Matsuo and Kenji Natori and Keiichiro Kondo",
year = "2017",
month = "1",
day = "1",
doi = "10.1541/ieejias.137.687",
language = "English",
volume = "137",
pages = "687--695",
journal = "IEEJ Transactions on Industry Applications",
issn = "0913-6339",
publisher = "The Institute of Electrical Engineers of Japan",
number = "9",

}

TY - JOUR

T1 - Continuous operation control of PMSM with compressor loads of air conditioners in case of DC power supply loss

AU - Heo, Jongwon

AU - Matsuo, Kentaro

AU - Natori, Kenji

AU - Kondo, Keiichiro

PY - 2017/1/1

Y1 - 2017/1/1

N2 - The interruption of power supply is one of the major technical issues in rotation angle sensorless controls of PMSMs. This causes failures of inverter operation due to voltage drop in filter capacitor (FC). In order to solve this technical issue, we propose a method to achieve continuous operation of PMSMs with low inertia loads, for example compressors of air conditioners, in case of power supply interruption. In the proposed method, the current reference is determined according to the relationship between the kinetic energy of the motor and the electrical energy of the FC to effectively use the available energy. The proposed method is validated by experimental test of 1-kW class PMSM.

AB - The interruption of power supply is one of the major technical issues in rotation angle sensorless controls of PMSMs. This causes failures of inverter operation due to voltage drop in filter capacitor (FC). In order to solve this technical issue, we propose a method to achieve continuous operation of PMSMs with low inertia loads, for example compressors of air conditioners, in case of power supply interruption. In the proposed method, the current reference is determined according to the relationship between the kinetic energy of the motor and the electrical energy of the FC to effectively use the available energy. The proposed method is validated by experimental test of 1-kW class PMSM.

KW - Continued operation

KW - Low inertial loads

KW - PMSM

KW - Power supply loss

KW - Sensorless control

UR - http://www.scopus.com/inward/record.url?scp=85028949447&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85028949447&partnerID=8YFLogxK

U2 - 10.1541/ieejias.137.687

DO - 10.1541/ieejias.137.687

M3 - Article

VL - 137

SP - 687

EP - 695

JO - IEEJ Transactions on Industry Applications

JF - IEEJ Transactions on Industry Applications

SN - 0913-6339