TY - JOUR
T1 - Demonstration of multiple contrast agent imaging for the next generation color X-ray CT
AU - Maruhashi, T.
AU - Kiji, H.
AU - Toyoda, T.
AU - Kataoka, J.
AU - Arimoto, M.
AU - Kobayashi, S.
AU - Kawashima, H.
AU - Terazawa, S.
AU - Shiota, S.
AU - Ikeda, H.
N1 - Funding Information:
This work was supported by JSPS KAKENHI (Japan) Grant NumberJP15H05720, JP16H07266 and the Key Researchers Development Program at Waseda University, Japan. M.A. acknowledges the support from the JSPS Leading Initiative for Excellent Young Researchers program (Japan) and the Naito Foundation, Japan.
Funding Information:
This work was supported by JSPS KAKENHI (Japan) Grant Number JP15H05720 , JP16H07266 and the Key Researchers Development Program at Waseda University, Japan . M.A. acknowledges the support from the JSPS Leading Initiative for Excellent Young Researchers program (Japan) and the Naito Foundation, Japan .
Publisher Copyright:
© 2019 Elsevier B.V.
PY - 2020/4/1
Y1 - 2020/4/1
N2 - X-ray computed tomography (CT) is widely used for non-invasive diagnostic imaging of the inside of the human body. It should be noted that the approximate effective radiation dose in a patient is 10 mSv. Under such an environment, X-ray photons are severely piled-up. Therefore, conventional CT only reconstructs energy integrated image, which may consist of beam hardening artifacts that have proven to be a problem. In contrast, photon counting CT (PC-CT) offers a low-dose multicolor CT imaging. The PC-CT also enables K-edge imaging that can improve the blood–tissue contrast using specific contrast agents. Moreover, the PC-CT has great advantages in (1) the simultaneous imaging of multiple contrast agents, and (2) the absolute quantification of contrast agents. Owing to these advantages, the PC-CT system can provide more detailed tissue diagnosis than conventional CT systems. Recently, we proposed a novel PC-CT system (Morita et al., 2017; Arimoto et al., 2017, Maruhashi et al., 2018) consisting of multipixel photon counter (MPPC) coupled with a high-speed scintillator, which is a cost-effective and easy to assemble system, as compared to other PC-CT devices based on cadmium zinc telluride. In this paper, we operated the K-edge imaging of specific contrast agents using a 16-channel MPPC PC-CT system. Our PC-CT system established appropriate energy thresholds and operated the simultaneous imaging of multiple contrast agents such as iodine and gadolinium. In addition, we estimated the absolute concentration of these contrast agents. The results show that our PC-CT system can provide more accurate diagnostic medical imaging, as compared to the conventional CT system.
AB - X-ray computed tomography (CT) is widely used for non-invasive diagnostic imaging of the inside of the human body. It should be noted that the approximate effective radiation dose in a patient is 10 mSv. Under such an environment, X-ray photons are severely piled-up. Therefore, conventional CT only reconstructs energy integrated image, which may consist of beam hardening artifacts that have proven to be a problem. In contrast, photon counting CT (PC-CT) offers a low-dose multicolor CT imaging. The PC-CT also enables K-edge imaging that can improve the blood–tissue contrast using specific contrast agents. Moreover, the PC-CT has great advantages in (1) the simultaneous imaging of multiple contrast agents, and (2) the absolute quantification of contrast agents. Owing to these advantages, the PC-CT system can provide more detailed tissue diagnosis than conventional CT systems. Recently, we proposed a novel PC-CT system (Morita et al., 2017; Arimoto et al., 2017, Maruhashi et al., 2018) consisting of multipixel photon counter (MPPC) coupled with a high-speed scintillator, which is a cost-effective and easy to assemble system, as compared to other PC-CT devices based on cadmium zinc telluride. In this paper, we operated the K-edge imaging of specific contrast agents using a 16-channel MPPC PC-CT system. Our PC-CT system established appropriate energy thresholds and operated the simultaneous imaging of multiple contrast agents such as iodine and gadolinium. In addition, we estimated the absolute concentration of these contrast agents. The results show that our PC-CT system can provide more accurate diagnostic medical imaging, as compared to the conventional CT system.
KW - K-edge imaging
KW - Multipixel photon counter
KW - Photon counting computed tomography
UR - http://www.scopus.com/inward/record.url?scp=85072576321&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85072576321&partnerID=8YFLogxK
U2 - 10.1016/j.nima.2019.162801
DO - 10.1016/j.nima.2019.162801
M3 - Article