Abstract
Sumitomo Electric (SEI) has been involved in the development of 66 kV-class HTS cables using REBCO wires. One of the technical targets is to reduce the AC loss to less than 2 W/m/phase at 5 kA. SEI has developed a clad-type textured metal substrate with lower magnetization loss than NiW substrate. REBCO tapes 30 mm-wide were slit into 4 mm-wide strips, and these strips were wound spirally on a former with small gaps. The measured AC loss of the manufactured cable was 1.8 W/m/phase at 5 kA, achieving the AC loss goal.
Original language | English |
---|---|
Pages (from-to) | 849-854 |
Number of pages | 6 |
Journal | Physics Procedia |
Volume | 36 |
DOIs | |
Publication status | Published - 2012 |
Event | Superconductivity Centennial Conference, SCC 2011 - The Hague, Netherlands Duration: 2011 Sept 18 → 2011 Sept 23 |
Keywords
- Ac loss
- Power transmission cables
- Rebco wires
ASJC Scopus subject areas
- Physics and Astronomy(all)