Design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems

Hiroshi Miyazaki, Sadanori Iwai, Yasumi Otani, Masahiko Takahashi, Taizo Tosaka, Kenji Tasaki, Shunji Nomura, Tsutomu Kurusu, Hiroshi Ueda, So Noguchi, Atsushi Ishiyama, Shinichi Urayama, Hidenao Fukuyama

    Research output: Contribution to journalArticle

    10 Citations (Scopus)

    Abstract

    A project on the development of REBa2Cu3O7-δ (REBCO) magnets for ultra-high-field magnetic resonance imaging (MRI) was started in 2013. Since REBCO-coated conductors feature high mechanical strength under tensile stress and high critical current density, use of REBCO coils would allow superconducting magnets to be made smaller and lighter than conventional ones. In addition, a conduction-cooled superconducting magnet is simpler to use than one cooled by a liquid helium bath because the operation and maintenance of the cryogenic system become simpler, without the need to handle cryogenic fluid. Superconducting magnets for MRI require homogeneous, stable magnetic fields. The homogeneity of the magnetic field is highly dependent on the coil shape and position. Moreover, in REBCO magnets, the screening-current-induced magnetic field, which changes the magnetic field distribution of the magnet, is one of the critical issues. In order to evaluate the magnetic field homogeneity and the screening-current-induced magnetic field, a 1 T model magnet and some test coils were fabricated. From an evaluation of the 1 T model magnet, it was found that the main reason for magnetic field inhomogeneity was the tolerances in the z-axis positions of the coils, and therefore, it is important to control the gap between the single pancakes. In addition, we have already demonstrated the generation of an 8.27 T central magnetic field at 10 K with a small test coil. The screening-current-induced magnetic field was 0.43 T and was predictable by using an electromagnetic field simulation program. These results were reflected in the design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems. The magnet was composed of six main coils and two active shield coils. The total conductor length was 581 km, and the stored energy was 293 kJ. The field inhomogeneity was 24 ppm peak to peak and 3 ppm volume-root-mean-square (VRMS) for a 500 mm diameter spherical volume (DSV). The axial and radial 5 gauss line locations were less than 5 m and 4.2 m respectively.

    Original languageEnglish
    Article number104001
    JournalSuperconductor Science and Technology
    Volume29
    Issue number10
    DOIs
    Publication statusPublished - 2016 Aug 12

    Fingerprint

    Magnetic resonance
    Imaging systems
    Magnets
    magnetic resonance
    magnets
    Magnetic fields
    conduction
    coils
    magnetic fields
    Superconducting magnets
    Induced currents
    superconducting magnets
    Screening
    screening
    Cryogenics
    homogeneity
    inhomogeneity
    conductors
    cryogenic fluids
    Imaging techniques

    Keywords

    • conduction-cooled
    • REBCO
    • ultra-high-field MRI

    ASJC Scopus subject areas

    • Ceramics and Composites
    • Condensed Matter Physics
    • Metals and Alloys
    • Materials Chemistry
    • Electrical and Electronic Engineering

    Cite this

    Miyazaki, H., Iwai, S., Otani, Y., Takahashi, M., Tosaka, T., Tasaki, K., ... Fukuyama, H. (2016). Design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems. Superconductor Science and Technology, 29(10), [104001]. https://doi.org/10.1088/0953-2048/29/10/104001

    Design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems. / Miyazaki, Hiroshi; Iwai, Sadanori; Otani, Yasumi; Takahashi, Masahiko; Tosaka, Taizo; Tasaki, Kenji; Nomura, Shunji; Kurusu, Tsutomu; Ueda, Hiroshi; Noguchi, So; Ishiyama, Atsushi; Urayama, Shinichi; Fukuyama, Hidenao.

    In: Superconductor Science and Technology, Vol. 29, No. 10, 104001, 12.08.2016.

    Research output: Contribution to journalArticle

    Miyazaki, H, Iwai, S, Otani, Y, Takahashi, M, Tosaka, T, Tasaki, K, Nomura, S, Kurusu, T, Ueda, H, Noguchi, S, Ishiyama, A, Urayama, S & Fukuyama, H 2016, 'Design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems', Superconductor Science and Technology, vol. 29, no. 10, 104001. https://doi.org/10.1088/0953-2048/29/10/104001
    Miyazaki, Hiroshi ; Iwai, Sadanori ; Otani, Yasumi ; Takahashi, Masahiko ; Tosaka, Taizo ; Tasaki, Kenji ; Nomura, Shunji ; Kurusu, Tsutomu ; Ueda, Hiroshi ; Noguchi, So ; Ishiyama, Atsushi ; Urayama, Shinichi ; Fukuyama, Hidenao. / Design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems. In: Superconductor Science and Technology. 2016 ; Vol. 29, No. 10.
    @article{80545c13e3d84abda2b616101ab9f268,
    title = "Design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems",
    abstract = "A project on the development of REBa2Cu3O7-δ (REBCO) magnets for ultra-high-field magnetic resonance imaging (MRI) was started in 2013. Since REBCO-coated conductors feature high mechanical strength under tensile stress and high critical current density, use of REBCO coils would allow superconducting magnets to be made smaller and lighter than conventional ones. In addition, a conduction-cooled superconducting magnet is simpler to use than one cooled by a liquid helium bath because the operation and maintenance of the cryogenic system become simpler, without the need to handle cryogenic fluid. Superconducting magnets for MRI require homogeneous, stable magnetic fields. The homogeneity of the magnetic field is highly dependent on the coil shape and position. Moreover, in REBCO magnets, the screening-current-induced magnetic field, which changes the magnetic field distribution of the magnet, is one of the critical issues. In order to evaluate the magnetic field homogeneity and the screening-current-induced magnetic field, a 1 T model magnet and some test coils were fabricated. From an evaluation of the 1 T model magnet, it was found that the main reason for magnetic field inhomogeneity was the tolerances in the z-axis positions of the coils, and therefore, it is important to control the gap between the single pancakes. In addition, we have already demonstrated the generation of an 8.27 T central magnetic field at 10 K with a small test coil. The screening-current-induced magnetic field was 0.43 T and was predictable by using an electromagnetic field simulation program. These results were reflected in the design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems. The magnet was composed of six main coils and two active shield coils. The total conductor length was 581 km, and the stored energy was 293 kJ. The field inhomogeneity was 24 ppm peak to peak and 3 ppm volume-root-mean-square (VRMS) for a 500 mm diameter spherical volume (DSV). The axial and radial 5 gauss line locations were less than 5 m and 4.2 m respectively.",
    keywords = "conduction-cooled, REBCO, ultra-high-field MRI",
    author = "Hiroshi Miyazaki and Sadanori Iwai and Yasumi Otani and Masahiko Takahashi and Taizo Tosaka and Kenji Tasaki and Shunji Nomura and Tsutomu Kurusu and Hiroshi Ueda and So Noguchi and Atsushi Ishiyama and Shinichi Urayama and Hidenao Fukuyama",
    year = "2016",
    month = "8",
    day = "12",
    doi = "10.1088/0953-2048/29/10/104001",
    language = "English",
    volume = "29",
    journal = "Superconductor Science and Technology",
    issn = "0953-2048",
    publisher = "IOP Publishing Ltd.",
    number = "10",

    }

    TY - JOUR

    T1 - Design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems

    AU - Miyazaki, Hiroshi

    AU - Iwai, Sadanori

    AU - Otani, Yasumi

    AU - Takahashi, Masahiko

    AU - Tosaka, Taizo

    AU - Tasaki, Kenji

    AU - Nomura, Shunji

    AU - Kurusu, Tsutomu

    AU - Ueda, Hiroshi

    AU - Noguchi, So

    AU - Ishiyama, Atsushi

    AU - Urayama, Shinichi

    AU - Fukuyama, Hidenao

    PY - 2016/8/12

    Y1 - 2016/8/12

    N2 - A project on the development of REBa2Cu3O7-δ (REBCO) magnets for ultra-high-field magnetic resonance imaging (MRI) was started in 2013. Since REBCO-coated conductors feature high mechanical strength under tensile stress and high critical current density, use of REBCO coils would allow superconducting magnets to be made smaller and lighter than conventional ones. In addition, a conduction-cooled superconducting magnet is simpler to use than one cooled by a liquid helium bath because the operation and maintenance of the cryogenic system become simpler, without the need to handle cryogenic fluid. Superconducting magnets for MRI require homogeneous, stable magnetic fields. The homogeneity of the magnetic field is highly dependent on the coil shape and position. Moreover, in REBCO magnets, the screening-current-induced magnetic field, which changes the magnetic field distribution of the magnet, is one of the critical issues. In order to evaluate the magnetic field homogeneity and the screening-current-induced magnetic field, a 1 T model magnet and some test coils were fabricated. From an evaluation of the 1 T model magnet, it was found that the main reason for magnetic field inhomogeneity was the tolerances in the z-axis positions of the coils, and therefore, it is important to control the gap between the single pancakes. In addition, we have already demonstrated the generation of an 8.27 T central magnetic field at 10 K with a small test coil. The screening-current-induced magnetic field was 0.43 T and was predictable by using an electromagnetic field simulation program. These results were reflected in the design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems. The magnet was composed of six main coils and two active shield coils. The total conductor length was 581 km, and the stored energy was 293 kJ. The field inhomogeneity was 24 ppm peak to peak and 3 ppm volume-root-mean-square (VRMS) for a 500 mm diameter spherical volume (DSV). The axial and radial 5 gauss line locations were less than 5 m and 4.2 m respectively.

    AB - A project on the development of REBa2Cu3O7-δ (REBCO) magnets for ultra-high-field magnetic resonance imaging (MRI) was started in 2013. Since REBCO-coated conductors feature high mechanical strength under tensile stress and high critical current density, use of REBCO coils would allow superconducting magnets to be made smaller and lighter than conventional ones. In addition, a conduction-cooled superconducting magnet is simpler to use than one cooled by a liquid helium bath because the operation and maintenance of the cryogenic system become simpler, without the need to handle cryogenic fluid. Superconducting magnets for MRI require homogeneous, stable magnetic fields. The homogeneity of the magnetic field is highly dependent on the coil shape and position. Moreover, in REBCO magnets, the screening-current-induced magnetic field, which changes the magnetic field distribution of the magnet, is one of the critical issues. In order to evaluate the magnetic field homogeneity and the screening-current-induced magnetic field, a 1 T model magnet and some test coils were fabricated. From an evaluation of the 1 T model magnet, it was found that the main reason for magnetic field inhomogeneity was the tolerances in the z-axis positions of the coils, and therefore, it is important to control the gap between the single pancakes. In addition, we have already demonstrated the generation of an 8.27 T central magnetic field at 10 K with a small test coil. The screening-current-induced magnetic field was 0.43 T and was predictable by using an electromagnetic field simulation program. These results were reflected in the design of a conduction-cooled 9.4 T REBCO magnet for whole-body MRI systems. The magnet was composed of six main coils and two active shield coils. The total conductor length was 581 km, and the stored energy was 293 kJ. The field inhomogeneity was 24 ppm peak to peak and 3 ppm volume-root-mean-square (VRMS) for a 500 mm diameter spherical volume (DSV). The axial and radial 5 gauss line locations were less than 5 m and 4.2 m respectively.

    KW - conduction-cooled

    KW - REBCO

    KW - ultra-high-field MRI

    UR - http://www.scopus.com/inward/record.url?scp=84989964164&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84989964164&partnerID=8YFLogxK

    U2 - 10.1088/0953-2048/29/10/104001

    DO - 10.1088/0953-2048/29/10/104001

    M3 - Article

    AN - SCOPUS:84989964164

    VL - 29

    JO - Superconductor Science and Technology

    JF - Superconductor Science and Technology

    SN - 0953-2048

    IS - 10

    M1 - 104001

    ER -