TY - JOUR
T1 - Development of a GdSiO (GPS) Scintillator-Based Alpha Imaging Detector for Rapid Plutonium Detection in High-Radon Environments
AU - Morishita, Yuki
AU - Izaki, Kenji
AU - Kaneko, Junichi H.
AU - Yamamoto, Seiichi
AU - Higuchi, Mikio
AU - Torii, Tatsuo
N1 - Funding Information:
ACKNOWLEDGMENT This research was supported in-part by the Development of Systems and Technology for Advanced Measurement and Analysis Project from Japan Science and Technology Agency, JST.
Publisher Copyright:
© 1963-2012 IEEE.
PY - 2020/10
Y1 - 2020/10
N2 - We developed a Gd2Si2O7 (GPS) scintillator-based alpha imaging detector and demonstrated its effectiveness by evaluating the actual Pu particle and 222Rn progeny. The GPS scintillator plate was prepared by a sintering method. The outer dimensions of the GPS scintillator plate were $5\times 5$ cm, and the scintillator layer was approximately $50~\mu \text{m}$ on a 3-mm-thick high-transparency glass. The plate was optically coupled to a position-sensitive photomultiplier tube (Hamamatsu H8500, Hamamatsu, Japan) with silicone grease. The developed imaging detector exhibited good uniformity; Pu particle activities were accurately evaluated at 14 different positions and the difference in activity was within ±6%. The radon-222 progeny counts were reduced by 65.3% by applying an energy window. Although the Pu/222Rn progeny activity ratio was 1/51, the Pu particle was successfully identified among the 222Rn progeny within the 5-min measurement time. The imaging detector has an excellent ability for detecting Pu among the 222Rn progeny. Thus, this detector is useful for alpha contamination monitoring in high-radon-background environments.
AB - We developed a Gd2Si2O7 (GPS) scintillator-based alpha imaging detector and demonstrated its effectiveness by evaluating the actual Pu particle and 222Rn progeny. The GPS scintillator plate was prepared by a sintering method. The outer dimensions of the GPS scintillator plate were $5\times 5$ cm, and the scintillator layer was approximately $50~\mu \text{m}$ on a 3-mm-thick high-transparency glass. The plate was optically coupled to a position-sensitive photomultiplier tube (Hamamatsu H8500, Hamamatsu, Japan) with silicone grease. The developed imaging detector exhibited good uniformity; Pu particle activities were accurately evaluated at 14 different positions and the difference in activity was within ±6%. The radon-222 progeny counts were reduced by 65.3% by applying an energy window. Although the Pu/222Rn progeny activity ratio was 1/51, the Pu particle was successfully identified among the 222Rn progeny within the 5-min measurement time. The imaging detector has an excellent ability for detecting Pu among the 222Rn progeny. Thus, this detector is useful for alpha contamination monitoring in high-radon-background environments.
KW - Alpha-particle imaging detector
KW - Gd₂Si₂O₇ (GPS) scintillator plate
KW - plutonium
KW - radon
UR - http://www.scopus.com/inward/record.url?scp=85094098573&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85094098573&partnerID=8YFLogxK
U2 - 10.1109/TNS.2020.3014997
DO - 10.1109/TNS.2020.3014997
M3 - Article
AN - SCOPUS:85094098573
SN - 0018-9499
VL - 67
SP - 2203
EP - 2208
JO - IEEE Transactions on Nuclear Science
JF - IEEE Transactions on Nuclear Science
IS - 10
M1 - 9162144
ER -