Development of an ex vivo brain lactic acid monitoring system

Shuya Negishi, Shoto Kamada, Riichi Kajiwara, Yuji Kaneko, Donghyun Yoon, Tetsushi Sekiguchi, Shuichi Shoji, Hiroyuki Kudo

Research output: Contribution to journalArticle

Abstract

An ex vivo brain lactic acid (LA) monitoring system for investigating brain activity at the organ level was constructed and tested in continuous LA monitoring. Our system consists of a micro-fluidic dual-analyte (LA and glucose) biosensor and a special brain chamber that is suitable for organ level experiments. The biosensor utilizes the redox reactions of osmium-wired horseradish peroxidase (Os-HRP) to detect hydrogen peroxide produced by enzyme reactions. The sensor had sufficient sensitivity (LA: ∼ 0.01 mM, glucose: ∼ 0.01 mM) and selectivity for assessment of extracellular LA. The ex vivo monitoring of brain LA was performed using the proposed system. As a result, the change in extracellular LA was successfully monitored continuously, and the change in the LA level was considered the result of metabolic activity of the sample. Our system is expected to be useful not only for ex vivo brain monitoring, but also for monitoring other organs.

Original languageEnglish
Pages (from-to)38-43
Number of pages6
JournalIEEJ Transactions on Sensors and Micromachines
Volume137
Issue number1
DOIs
Publication statusPublished - 2017

Fingerprint

Lactic acid
Brain
Monitoring
Biosensors
Glucose
Osmium
Redox reactions
Fluidics
Hydrogen peroxide
Enzymes
Sensors

Keywords

  • Brain
  • Electrochemical
  • Ex vivo biomonitoring
  • Flow injection
  • Lactic acid
  • Real-time

ASJC Scopus subject areas

  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

Development of an ex vivo brain lactic acid monitoring system. / Negishi, Shuya; Kamada, Shoto; Kajiwara, Riichi; Kaneko, Yuji; Yoon, Donghyun; Sekiguchi, Tetsushi; Shoji, Shuichi; Kudo, Hiroyuki.

In: IEEJ Transactions on Sensors and Micromachines, Vol. 137, No. 1, 2017, p. 38-43.

Research output: Contribution to journalArticle

Negishi, Shuya ; Kamada, Shoto ; Kajiwara, Riichi ; Kaneko, Yuji ; Yoon, Donghyun ; Sekiguchi, Tetsushi ; Shoji, Shuichi ; Kudo, Hiroyuki. / Development of an ex vivo brain lactic acid monitoring system. In: IEEJ Transactions on Sensors and Micromachines. 2017 ; Vol. 137, No. 1. pp. 38-43.
@article{f4cf4127ddf543499cf958d17b779e7d,
title = "Development of an ex vivo brain lactic acid monitoring system",
abstract = "An ex vivo brain lactic acid (LA) monitoring system for investigating brain activity at the organ level was constructed and tested in continuous LA monitoring. Our system consists of a micro-fluidic dual-analyte (LA and glucose) biosensor and a special brain chamber that is suitable for organ level experiments. The biosensor utilizes the redox reactions of osmium-wired horseradish peroxidase (Os-HRP) to detect hydrogen peroxide produced by enzyme reactions. The sensor had sufficient sensitivity (LA: ∼ 0.01 mM, glucose: ∼ 0.01 mM) and selectivity for assessment of extracellular LA. The ex vivo monitoring of brain LA was performed using the proposed system. As a result, the change in extracellular LA was successfully monitored continuously, and the change in the LA level was considered the result of metabolic activity of the sample. Our system is expected to be useful not only for ex vivo brain monitoring, but also for monitoring other organs.",
keywords = "Brain, Electrochemical, Ex vivo biomonitoring, Flow injection, Lactic acid, Real-time",
author = "Shuya Negishi and Shoto Kamada and Riichi Kajiwara and Yuji Kaneko and Donghyun Yoon and Tetsushi Sekiguchi and Shuichi Shoji and Hiroyuki Kudo",
year = "2017",
doi = "10.1541/ieejsmas.137.38",
language = "English",
volume = "137",
pages = "38--43",
journal = "IEEJ Transactions on Sensors and Micromachines",
issn = "1341-8939",
publisher = "The Institute of Electrical Engineers of Japan",
number = "1",

}

TY - JOUR

T1 - Development of an ex vivo brain lactic acid monitoring system

AU - Negishi, Shuya

AU - Kamada, Shoto

AU - Kajiwara, Riichi

AU - Kaneko, Yuji

AU - Yoon, Donghyun

AU - Sekiguchi, Tetsushi

AU - Shoji, Shuichi

AU - Kudo, Hiroyuki

PY - 2017

Y1 - 2017

N2 - An ex vivo brain lactic acid (LA) monitoring system for investigating brain activity at the organ level was constructed and tested in continuous LA monitoring. Our system consists of a micro-fluidic dual-analyte (LA and glucose) biosensor and a special brain chamber that is suitable for organ level experiments. The biosensor utilizes the redox reactions of osmium-wired horseradish peroxidase (Os-HRP) to detect hydrogen peroxide produced by enzyme reactions. The sensor had sufficient sensitivity (LA: ∼ 0.01 mM, glucose: ∼ 0.01 mM) and selectivity for assessment of extracellular LA. The ex vivo monitoring of brain LA was performed using the proposed system. As a result, the change in extracellular LA was successfully monitored continuously, and the change in the LA level was considered the result of metabolic activity of the sample. Our system is expected to be useful not only for ex vivo brain monitoring, but also for monitoring other organs.

AB - An ex vivo brain lactic acid (LA) monitoring system for investigating brain activity at the organ level was constructed and tested in continuous LA monitoring. Our system consists of a micro-fluidic dual-analyte (LA and glucose) biosensor and a special brain chamber that is suitable for organ level experiments. The biosensor utilizes the redox reactions of osmium-wired horseradish peroxidase (Os-HRP) to detect hydrogen peroxide produced by enzyme reactions. The sensor had sufficient sensitivity (LA: ∼ 0.01 mM, glucose: ∼ 0.01 mM) and selectivity for assessment of extracellular LA. The ex vivo monitoring of brain LA was performed using the proposed system. As a result, the change in extracellular LA was successfully monitored continuously, and the change in the LA level was considered the result of metabolic activity of the sample. Our system is expected to be useful not only for ex vivo brain monitoring, but also for monitoring other organs.

KW - Brain

KW - Electrochemical

KW - Ex vivo biomonitoring

KW - Flow injection

KW - Lactic acid

KW - Real-time

UR - http://www.scopus.com/inward/record.url?scp=85008155533&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85008155533&partnerID=8YFLogxK

U2 - 10.1541/ieejsmas.137.38

DO - 10.1541/ieejsmas.137.38

M3 - Article

AN - SCOPUS:85008155533

VL - 137

SP - 38

EP - 43

JO - IEEJ Transactions on Sensors and Micromachines

JF - IEEJ Transactions on Sensors and Micromachines

SN - 1341-8939

IS - 1