TY - GEN
T1 - Development of an optofluidic SERS-based biomedical sensor
AU - Walton, Brian
AU - Huang, Po Jung
AU - Kameoka, Jun
AU - Deutz, Nicolaas
AU - Coté, Gerard L.
N1 - Funding Information:
Research reported in this publication was supported by the National Institute of Environmental Health Sciences of the National Institutes of Health under grant number P30ES023512. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.
Publisher Copyright:
© 2016 SPIE.
PY - 2016
Y1 - 2016
N2 - Rapid assessment of radiation exposure to sensitive organs like the gut is extremely important for large populations exposed to ionized radiation, for instance during warfare. Recent results have shown that plasma citrulline levels appear to track gut function after irradiation levels in mice and humans. The current ways to monitor blood citrulline levels are bulky, laborious, time-consuming and expensive methods. Therefore, an optofludic point-of-care (POC) system using surface enhanced Raman spectroscopy to measure plasma citrulline as a marker for radiation exposure that overcomes the above issues is being developed. As a first step toward development of this system four colloidal nanoparticles, spherical gold, silver cubes, silica-gold nanoshells, and silver-gold nanocages have been analyzed for use in the POC system. Transmission electron microscopy (TEM) images have been taken of each nanoparticle to visualize the morphology of the nanoparticles, which is vital for SERS. Ultraviolet-visible (UV/Vis) spectroscopy was also collected to verify the extinction spectra for each nanoparticle was in resonance with the excitation wavelength. The nanoparticles were functionalized with mercaptobenzoic acid (MBA), a Raman reporter molecule, and SERS spectra were collected to determine which has better utility in a novel micro-to-nanochannel. The data showed that the silver nanocubes have a larger enhancement factor than the gold nanospheres, nanoshells, or nanocages. Currently, these nanocubes are being functionalized with the citulline for assessing the concentration sensitivity and dynamic range for ultimate use as a marker for radiation.
AB - Rapid assessment of radiation exposure to sensitive organs like the gut is extremely important for large populations exposed to ionized radiation, for instance during warfare. Recent results have shown that plasma citrulline levels appear to track gut function after irradiation levels in mice and humans. The current ways to monitor blood citrulline levels are bulky, laborious, time-consuming and expensive methods. Therefore, an optofludic point-of-care (POC) system using surface enhanced Raman spectroscopy to measure plasma citrulline as a marker for radiation exposure that overcomes the above issues is being developed. As a first step toward development of this system four colloidal nanoparticles, spherical gold, silver cubes, silica-gold nanoshells, and silver-gold nanocages have been analyzed for use in the POC system. Transmission electron microscopy (TEM) images have been taken of each nanoparticle to visualize the morphology of the nanoparticles, which is vital for SERS. Ultraviolet-visible (UV/Vis) spectroscopy was also collected to verify the extinction spectra for each nanoparticle was in resonance with the excitation wavelength. The nanoparticles were functionalized with mercaptobenzoic acid (MBA), a Raman reporter molecule, and SERS spectra were collected to determine which has better utility in a novel micro-to-nanochannel. The data showed that the silver nanocubes have a larger enhancement factor than the gold nanospheres, nanoshells, or nanocages. Currently, these nanocubes are being functionalized with the citulline for assessing the concentration sensitivity and dynamic range for ultimate use as a marker for radiation.
KW - micro-to-nanochannel
KW - nanoparticles
KW - SERS
UR - http://www.scopus.com/inward/record.url?scp=84983000328&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84983000328&partnerID=8YFLogxK
U2 - 10.1117/12.2213909
DO - 10.1117/12.2213909
M3 - Conference contribution
AN - SCOPUS:84983000328
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Optical Diagnostics and Sensing XVI
A2 - Cote, Gerard L.
PB - SPIE
T2 - Optical Diagnostics and Sensing XVI: Toward Point-of-Care Diagnostics
Y2 - 15 February 2016 through 16 February 2016
ER -