Differences in tunneling time between 77 K and room temperature for tunneling biquantum wells

Atsushi Tackeuchi, Yoshihiro Sugiyama, Tsuguo Inata, Shunichi Muto

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

We measured the recovery time from excitonic absorption bleaching in tunneling biquantum wells at 77 K and room temperature. The absorption recovery time corresponds to the tunneling time of electrons from narrow to wide wells. We have found that tunneling at 77b K is about 2.5 times slower than at room temperature.

Original languageEnglish
Pages (from-to)3823-3824
Number of pages2
JournalJapanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers
Volume31
Issue number12 A
Publication statusPublished - 1992 Dec
Externally publishedYes

Fingerprint

Recovery
room temperature
Bleaching
recovery
bleaching
Temperature
temperature
Electrons
electrons

ASJC Scopus subject areas

  • Physics and Astronomy (miscellaneous)

Cite this

Differences in tunneling time between 77 K and room temperature for tunneling biquantum wells. / Tackeuchi, Atsushi; Sugiyama, Yoshihiro; Inata, Tsuguo; Muto, Shunichi.

In: Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, Vol. 31, No. 12 A, 12.1992, p. 3823-3824.

Research output: Contribution to journalArticle

@article{51ea9bc8ee9742d287cfee2839d74352,
title = "Differences in tunneling time between 77 K and room temperature for tunneling biquantum wells",
abstract = "We measured the recovery time from excitonic absorption bleaching in tunneling biquantum wells at 77 K and room temperature. The absorption recovery time corresponds to the tunneling time of electrons from narrow to wide wells. We have found that tunneling at 77b K is about 2.5 times slower than at room temperature.",
author = "Atsushi Tackeuchi and Yoshihiro Sugiyama and Tsuguo Inata and Shunichi Muto",
year = "1992",
month = "12",
language = "English",
volume = "31",
pages = "3823--3824",
journal = "Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes",
issn = "0021-4922",
publisher = "Japan Society of Applied Physics",
number = "12 A",

}

TY - JOUR

T1 - Differences in tunneling time between 77 K and room temperature for tunneling biquantum wells

AU - Tackeuchi, Atsushi

AU - Sugiyama, Yoshihiro

AU - Inata, Tsuguo

AU - Muto, Shunichi

PY - 1992/12

Y1 - 1992/12

N2 - We measured the recovery time from excitonic absorption bleaching in tunneling biquantum wells at 77 K and room temperature. The absorption recovery time corresponds to the tunneling time of electrons from narrow to wide wells. We have found that tunneling at 77b K is about 2.5 times slower than at room temperature.

AB - We measured the recovery time from excitonic absorption bleaching in tunneling biquantum wells at 77 K and room temperature. The absorption recovery time corresponds to the tunneling time of electrons from narrow to wide wells. We have found that tunneling at 77b K is about 2.5 times slower than at room temperature.

UR - http://www.scopus.com/inward/record.url?scp=0026962536&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026962536&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0026962536

VL - 31

SP - 3823

EP - 3824

JO - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes

JF - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes

SN - 0021-4922

IS - 12 A

ER -