Digital cell counting device integrated with a single-cell array

Tatsuya Saeki, Masahito Hosokawa, Tae Kyu Lim, Manabu Harada, Tadashi Matsunaga, Tsuyoshi Tanaka

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

In this paper, we present a novel cell counting method accomplished using a single-cell array fabricated on an image sensor, complementary metal oxide semiconductor sensor. The single-cell array was constructed using a microcavity array, which can trap up to 7,500 single cells on microcavities periodically arranged on a plane metallic substrate via the application of a negative pressure. The proposed method for cell counting is based on shadow imaging, which uses a light diffraction pattern generated by the microcavity array and trapped cells. Under illumination, the cell-occupied microcavities are visualized as shadow patterns in an image recorded by the complementary metal oxide semiconductor sensor due to light attenuation. The cell count is determined by enumerating the uniform shadow patterns created from one-on-one relationships with single cells trapped on the microcavities in digital format. In the experiment, all cell counting processes including entrapment of non-labeled HeLa cells from suspensions on the array and image acquisition of a wide-field-of-view of 30 mm2 in 1/60 seconds were implemented in a single integrated device. As a result, the results from the digital cell counting had a linear relationship with those obtained from microscopic observation (r2 = 0.99). This platform could be used at extremely low cell concentrations, i.e., 25-15,000 cells/mL. Our proposed system provides a simple and rapid miniaturized cell counting device for routine laboratory use.

Original languageEnglish
Article numbere89011
JournalPLoS One
Volume9
Issue number2
DOIs
Publication statusPublished - 2014 Feb 13
Externally publishedYes

Fingerprint

Microcavities
Equipment and Supplies
cells
Metals
Image acquisition
Sensors
Image sensors
Semiconductors
Diffraction patterns
sensors (equipment)
semiconductors
Suspensions
Lighting
Oxides
Imaging techniques
oxides
Substrates
Light
metals
HeLa Cells

ASJC Scopus subject areas

  • Agricultural and Biological Sciences(all)
  • Biochemistry, Genetics and Molecular Biology(all)
  • Medicine(all)

Cite this

Saeki, T., Hosokawa, M., Lim, T. K., Harada, M., Matsunaga, T., & Tanaka, T. (2014). Digital cell counting device integrated with a single-cell array. PLoS One, 9(2), [e89011]. https://doi.org/10.1371/journal.pone.0089011

Digital cell counting device integrated with a single-cell array. / Saeki, Tatsuya; Hosokawa, Masahito; Lim, Tae Kyu; Harada, Manabu; Matsunaga, Tadashi; Tanaka, Tsuyoshi.

In: PLoS One, Vol. 9, No. 2, e89011, 13.02.2014.

Research output: Contribution to journalArticle

Saeki, T, Hosokawa, M, Lim, TK, Harada, M, Matsunaga, T & Tanaka, T 2014, 'Digital cell counting device integrated with a single-cell array', PLoS One, vol. 9, no. 2, e89011. https://doi.org/10.1371/journal.pone.0089011
Saeki, Tatsuya ; Hosokawa, Masahito ; Lim, Tae Kyu ; Harada, Manabu ; Matsunaga, Tadashi ; Tanaka, Tsuyoshi. / Digital cell counting device integrated with a single-cell array. In: PLoS One. 2014 ; Vol. 9, No. 2.
@article{28a85714758640fcbb73fdce69484001,
title = "Digital cell counting device integrated with a single-cell array",
abstract = "In this paper, we present a novel cell counting method accomplished using a single-cell array fabricated on an image sensor, complementary metal oxide semiconductor sensor. The single-cell array was constructed using a microcavity array, which can trap up to 7,500 single cells on microcavities periodically arranged on a plane metallic substrate via the application of a negative pressure. The proposed method for cell counting is based on shadow imaging, which uses a light diffraction pattern generated by the microcavity array and trapped cells. Under illumination, the cell-occupied microcavities are visualized as shadow patterns in an image recorded by the complementary metal oxide semiconductor sensor due to light attenuation. The cell count is determined by enumerating the uniform shadow patterns created from one-on-one relationships with single cells trapped on the microcavities in digital format. In the experiment, all cell counting processes including entrapment of non-labeled HeLa cells from suspensions on the array and image acquisition of a wide-field-of-view of 30 mm2 in 1/60 seconds were implemented in a single integrated device. As a result, the results from the digital cell counting had a linear relationship with those obtained from microscopic observation (r2 = 0.99). This platform could be used at extremely low cell concentrations, i.e., 25-15,000 cells/mL. Our proposed system provides a simple and rapid miniaturized cell counting device for routine laboratory use.",
author = "Tatsuya Saeki and Masahito Hosokawa and Lim, {Tae Kyu} and Manabu Harada and Tadashi Matsunaga and Tsuyoshi Tanaka",
year = "2014",
month = "2",
day = "13",
doi = "10.1371/journal.pone.0089011",
language = "English",
volume = "9",
journal = "PLoS One",
issn = "1932-6203",
publisher = "Public Library of Science",
number = "2",

}

TY - JOUR

T1 - Digital cell counting device integrated with a single-cell array

AU - Saeki, Tatsuya

AU - Hosokawa, Masahito

AU - Lim, Tae Kyu

AU - Harada, Manabu

AU - Matsunaga, Tadashi

AU - Tanaka, Tsuyoshi

PY - 2014/2/13

Y1 - 2014/2/13

N2 - In this paper, we present a novel cell counting method accomplished using a single-cell array fabricated on an image sensor, complementary metal oxide semiconductor sensor. The single-cell array was constructed using a microcavity array, which can trap up to 7,500 single cells on microcavities periodically arranged on a plane metallic substrate via the application of a negative pressure. The proposed method for cell counting is based on shadow imaging, which uses a light diffraction pattern generated by the microcavity array and trapped cells. Under illumination, the cell-occupied microcavities are visualized as shadow patterns in an image recorded by the complementary metal oxide semiconductor sensor due to light attenuation. The cell count is determined by enumerating the uniform shadow patterns created from one-on-one relationships with single cells trapped on the microcavities in digital format. In the experiment, all cell counting processes including entrapment of non-labeled HeLa cells from suspensions on the array and image acquisition of a wide-field-of-view of 30 mm2 in 1/60 seconds were implemented in a single integrated device. As a result, the results from the digital cell counting had a linear relationship with those obtained from microscopic observation (r2 = 0.99). This platform could be used at extremely low cell concentrations, i.e., 25-15,000 cells/mL. Our proposed system provides a simple and rapid miniaturized cell counting device for routine laboratory use.

AB - In this paper, we present a novel cell counting method accomplished using a single-cell array fabricated on an image sensor, complementary metal oxide semiconductor sensor. The single-cell array was constructed using a microcavity array, which can trap up to 7,500 single cells on microcavities periodically arranged on a plane metallic substrate via the application of a negative pressure. The proposed method for cell counting is based on shadow imaging, which uses a light diffraction pattern generated by the microcavity array and trapped cells. Under illumination, the cell-occupied microcavities are visualized as shadow patterns in an image recorded by the complementary metal oxide semiconductor sensor due to light attenuation. The cell count is determined by enumerating the uniform shadow patterns created from one-on-one relationships with single cells trapped on the microcavities in digital format. In the experiment, all cell counting processes including entrapment of non-labeled HeLa cells from suspensions on the array and image acquisition of a wide-field-of-view of 30 mm2 in 1/60 seconds were implemented in a single integrated device. As a result, the results from the digital cell counting had a linear relationship with those obtained from microscopic observation (r2 = 0.99). This platform could be used at extremely low cell concentrations, i.e., 25-15,000 cells/mL. Our proposed system provides a simple and rapid miniaturized cell counting device for routine laboratory use.

UR - http://www.scopus.com/inward/record.url?scp=84903363975&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84903363975&partnerID=8YFLogxK

U2 - 10.1371/journal.pone.0089011

DO - 10.1371/journal.pone.0089011

M3 - Article

C2 - 24551208

AN - SCOPUS:84903363975

VL - 9

JO - PLoS One

JF - PLoS One

SN - 1932-6203

IS - 2

M1 - e89011

ER -