Dynamic intrameniscal stresses measurement in the porcine knee

P. K. Goh, F. K. Fuss, Toshimasa Yanai, A. C. Ritchie

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Intrameniscal stresses were measured with conductive pressure sensors inserted into the 2 menisci of a porcine knee joint. The stresses were measured at 3 different locations per meniscus, throughout the entire motion range and at increasing moments in extreme joint positions. The motions analysed were extension-flexion, and external-internal rotation at a 90° flexed knee. Meniscal peak stresses generally occurred in extreme positions, i.e., in maximal extension, maximal flexion, and maximal external and internal rotation. The measured stress increases with the moment applied to joint. In middle positions of the joint, the meniscus stress is minimal compared to extreme positions.

Original languageEnglish
Title of host publicationICBPE 2006 - Proceedings of the 2006 International Conference on Biomedical and Pharmaceutical Engineering
Pages194-196
Number of pages3
DOIs
Publication statusPublished - 2006
Externally publishedYes
EventICBPE 2006 - 2006 International Conference on Biomedical and Pharmaceutical Engineering - Singapore
Duration: 2006 Dec 112006 Dec 14

Other

OtherICBPE 2006 - 2006 International Conference on Biomedical and Pharmaceutical Engineering
CitySingapore
Period06/12/1106/12/14

Fingerprint

Stress measurement
Knee
Swine
Joints
Knee Joint
Articular Range of Motion
Pressure
Pressure sensors
Meniscus

Keywords

  • Joint moment
  • Knee flexion angle
  • Meniscus
  • Stress measurement

ASJC Scopus subject areas

  • Biomedical Engineering
  • Pharmacology (medical)
  • Pharmacology, Toxicology and Pharmaceutics(all)

Cite this

Goh, P. K., Fuss, F. K., Yanai, T., & Ritchie, A. C. (2006). Dynamic intrameniscal stresses measurement in the porcine knee. In ICBPE 2006 - Proceedings of the 2006 International Conference on Biomedical and Pharmaceutical Engineering (pp. 194-196). [4155890] https://doi.org/10.1109/ICBPE.2006.348581

Dynamic intrameniscal stresses measurement in the porcine knee. / Goh, P. K.; Fuss, F. K.; Yanai, Toshimasa; Ritchie, A. C.

ICBPE 2006 - Proceedings of the 2006 International Conference on Biomedical and Pharmaceutical Engineering. 2006. p. 194-196 4155890.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Goh, PK, Fuss, FK, Yanai, T & Ritchie, AC 2006, Dynamic intrameniscal stresses measurement in the porcine knee. in ICBPE 2006 - Proceedings of the 2006 International Conference on Biomedical and Pharmaceutical Engineering., 4155890, pp. 194-196, ICBPE 2006 - 2006 International Conference on Biomedical and Pharmaceutical Engineering, Singapore, 06/12/11. https://doi.org/10.1109/ICBPE.2006.348581
Goh PK, Fuss FK, Yanai T, Ritchie AC. Dynamic intrameniscal stresses measurement in the porcine knee. In ICBPE 2006 - Proceedings of the 2006 International Conference on Biomedical and Pharmaceutical Engineering. 2006. p. 194-196. 4155890 https://doi.org/10.1109/ICBPE.2006.348581
Goh, P. K. ; Fuss, F. K. ; Yanai, Toshimasa ; Ritchie, A. C. / Dynamic intrameniscal stresses measurement in the porcine knee. ICBPE 2006 - Proceedings of the 2006 International Conference on Biomedical and Pharmaceutical Engineering. 2006. pp. 194-196
@inproceedings{8d9df8cbe0ff4b76bad4823485fa890c,
title = "Dynamic intrameniscal stresses measurement in the porcine knee",
abstract = "Intrameniscal stresses were measured with conductive pressure sensors inserted into the 2 menisci of a porcine knee joint. The stresses were measured at 3 different locations per meniscus, throughout the entire motion range and at increasing moments in extreme joint positions. The motions analysed were extension-flexion, and external-internal rotation at a 90° flexed knee. Meniscal peak stresses generally occurred in extreme positions, i.e., in maximal extension, maximal flexion, and maximal external and internal rotation. The measured stress increases with the moment applied to joint. In middle positions of the joint, the meniscus stress is minimal compared to extreme positions.",
keywords = "Joint moment, Knee flexion angle, Meniscus, Stress measurement",
author = "Goh, {P. K.} and Fuss, {F. K.} and Toshimasa Yanai and Ritchie, {A. C.}",
year = "2006",
doi = "10.1109/ICBPE.2006.348581",
language = "English",
isbn = "8190426249",
pages = "194--196",
booktitle = "ICBPE 2006 - Proceedings of the 2006 International Conference on Biomedical and Pharmaceutical Engineering",

}

TY - GEN

T1 - Dynamic intrameniscal stresses measurement in the porcine knee

AU - Goh, P. K.

AU - Fuss, F. K.

AU - Yanai, Toshimasa

AU - Ritchie, A. C.

PY - 2006

Y1 - 2006

N2 - Intrameniscal stresses were measured with conductive pressure sensors inserted into the 2 menisci of a porcine knee joint. The stresses were measured at 3 different locations per meniscus, throughout the entire motion range and at increasing moments in extreme joint positions. The motions analysed were extension-flexion, and external-internal rotation at a 90° flexed knee. Meniscal peak stresses generally occurred in extreme positions, i.e., in maximal extension, maximal flexion, and maximal external and internal rotation. The measured stress increases with the moment applied to joint. In middle positions of the joint, the meniscus stress is minimal compared to extreme positions.

AB - Intrameniscal stresses were measured with conductive pressure sensors inserted into the 2 menisci of a porcine knee joint. The stresses were measured at 3 different locations per meniscus, throughout the entire motion range and at increasing moments in extreme joint positions. The motions analysed were extension-flexion, and external-internal rotation at a 90° flexed knee. Meniscal peak stresses generally occurred in extreme positions, i.e., in maximal extension, maximal flexion, and maximal external and internal rotation. The measured stress increases with the moment applied to joint. In middle positions of the joint, the meniscus stress is minimal compared to extreme positions.

KW - Joint moment

KW - Knee flexion angle

KW - Meniscus

KW - Stress measurement

UR - http://www.scopus.com/inward/record.url?scp=46249086149&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=46249086149&partnerID=8YFLogxK

U2 - 10.1109/ICBPE.2006.348581

DO - 10.1109/ICBPE.2006.348581

M3 - Conference contribution

AN - SCOPUS:46249086149

SN - 8190426249

SN - 9788190426244

SP - 194

EP - 196

BT - ICBPE 2006 - Proceedings of the 2006 International Conference on Biomedical and Pharmaceutical Engineering

ER -