Effect of human serum on the electrical detection of amyloid-β fibrils in biological environments using azo-dye immobilized field effect transistor (FET) biosensor

Sho Hideshima, Shofarul Wustoni, Masumi Kobayashi, Hiroki Hayashi, Shigeki Kuroiwa, Takuya Nakanishi, Tetsuya Osaka

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

As amyloid-β peptide 1–42 (Aβ42) was found to be an emerging and important biomarker for Alzheimer's disease, the detection of this peptide in biological samples such as human serum (HS) has become very important for evaluating the potential disease state and determining the appropriate treatment. In this study, we developed an electrical analysis strategy based on a field effect transistor (FET) biosensor as a simple and reliable technique for confirming the presence of Aβ42 aggregates (fibrils) in biological samples. By utilizing Congo red immobilized on the FET gate surface as a biorecognition element, we observed remarkable sensitivity and specificity for detecting Aβ42 fibrils. Furthermore, we optimized the procedure to minimize the interference of abundant human serum albumin for the detection system using HS samples. The optimized system of Congo red-immobilized FET enables measurement of Aβ42 fibrils in the 100-pM level in HS samples, which is lower than its clinical concentration. The FET device can be applied as a biosensing system for mass and routine screening of peptide biomarkers related to Alzheimer's disease.

Original languageEnglish
Pages (from-to)25-29
Number of pages5
JournalSensing and Bio-Sensing Research
Volume17
DOIs
Publication statusPublished - 2018 Feb 1

Fingerprint

Azo Compounds
Azo dyes
Biosensing Techniques
Field effect transistors
Amyloid
Biosensors
Peptides
Congo Red
Biomarkers
Serum
Gates (transistor)
Alzheimer Disease
Serum Albumin
Mass Screening
Screening
Sensitivity and Specificity
Equipment and Supplies

Keywords

  • Albumin-amyloid beta complexes
  • Alzheimer's disease
  • Amyloid beta fibrils
  • Field effect transistor biosensor
  • Human serum albumin

ASJC Scopus subject areas

  • Biotechnology
  • Electronic, Optical and Magnetic Materials
  • Signal Processing
  • Electrical and Electronic Engineering

Cite this

Effect of human serum on the electrical detection of amyloid-β fibrils in biological environments using azo-dye immobilized field effect transistor (FET) biosensor. / Hideshima, Sho; Wustoni, Shofarul; Kobayashi, Masumi; Hayashi, Hiroki; Kuroiwa, Shigeki; Nakanishi, Takuya; Osaka, Tetsuya.

In: Sensing and Bio-Sensing Research, Vol. 17, 01.02.2018, p. 25-29.

Research output: Contribution to journalArticle

@article{a8069536f8f34dc6b5b0666a3df28546,
title = "Effect of human serum on the electrical detection of amyloid-β fibrils in biological environments using azo-dye immobilized field effect transistor (FET) biosensor",
abstract = "As amyloid-β peptide 1–42 (Aβ42) was found to be an emerging and important biomarker for Alzheimer's disease, the detection of this peptide in biological samples such as human serum (HS) has become very important for evaluating the potential disease state and determining the appropriate treatment. In this study, we developed an electrical analysis strategy based on a field effect transistor (FET) biosensor as a simple and reliable technique for confirming the presence of Aβ42 aggregates (fibrils) in biological samples. By utilizing Congo red immobilized on the FET gate surface as a biorecognition element, we observed remarkable sensitivity and specificity for detecting Aβ42 fibrils. Furthermore, we optimized the procedure to minimize the interference of abundant human serum albumin for the detection system using HS samples. The optimized system of Congo red-immobilized FET enables measurement of Aβ42 fibrils in the 100-pM level in HS samples, which is lower than its clinical concentration. The FET device can be applied as a biosensing system for mass and routine screening of peptide biomarkers related to Alzheimer's disease.",
keywords = "Albumin-amyloid beta complexes, Alzheimer's disease, Amyloid beta fibrils, Field effect transistor biosensor, Human serum albumin",
author = "Sho Hideshima and Shofarul Wustoni and Masumi Kobayashi and Hiroki Hayashi and Shigeki Kuroiwa and Takuya Nakanishi and Tetsuya Osaka",
year = "2018",
month = "2",
day = "1",
doi = "10.1016/j.sbsr.2018.01.003",
language = "English",
volume = "17",
pages = "25--29",
journal = "Sensing and Bio-Sensing Research",
issn = "2214-1804",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Effect of human serum on the electrical detection of amyloid-β fibrils in biological environments using azo-dye immobilized field effect transistor (FET) biosensor

AU - Hideshima, Sho

AU - Wustoni, Shofarul

AU - Kobayashi, Masumi

AU - Hayashi, Hiroki

AU - Kuroiwa, Shigeki

AU - Nakanishi, Takuya

AU - Osaka, Tetsuya

PY - 2018/2/1

Y1 - 2018/2/1

N2 - As amyloid-β peptide 1–42 (Aβ42) was found to be an emerging and important biomarker for Alzheimer's disease, the detection of this peptide in biological samples such as human serum (HS) has become very important for evaluating the potential disease state and determining the appropriate treatment. In this study, we developed an electrical analysis strategy based on a field effect transistor (FET) biosensor as a simple and reliable technique for confirming the presence of Aβ42 aggregates (fibrils) in biological samples. By utilizing Congo red immobilized on the FET gate surface as a biorecognition element, we observed remarkable sensitivity and specificity for detecting Aβ42 fibrils. Furthermore, we optimized the procedure to minimize the interference of abundant human serum albumin for the detection system using HS samples. The optimized system of Congo red-immobilized FET enables measurement of Aβ42 fibrils in the 100-pM level in HS samples, which is lower than its clinical concentration. The FET device can be applied as a biosensing system for mass and routine screening of peptide biomarkers related to Alzheimer's disease.

AB - As amyloid-β peptide 1–42 (Aβ42) was found to be an emerging and important biomarker for Alzheimer's disease, the detection of this peptide in biological samples such as human serum (HS) has become very important for evaluating the potential disease state and determining the appropriate treatment. In this study, we developed an electrical analysis strategy based on a field effect transistor (FET) biosensor as a simple and reliable technique for confirming the presence of Aβ42 aggregates (fibrils) in biological samples. By utilizing Congo red immobilized on the FET gate surface as a biorecognition element, we observed remarkable sensitivity and specificity for detecting Aβ42 fibrils. Furthermore, we optimized the procedure to minimize the interference of abundant human serum albumin for the detection system using HS samples. The optimized system of Congo red-immobilized FET enables measurement of Aβ42 fibrils in the 100-pM level in HS samples, which is lower than its clinical concentration. The FET device can be applied as a biosensing system for mass and routine screening of peptide biomarkers related to Alzheimer's disease.

KW - Albumin-amyloid beta complexes

KW - Alzheimer's disease

KW - Amyloid beta fibrils

KW - Field effect transistor biosensor

KW - Human serum albumin

UR - http://www.scopus.com/inward/record.url?scp=85044436623&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85044436623&partnerID=8YFLogxK

U2 - 10.1016/j.sbsr.2018.01.003

DO - 10.1016/j.sbsr.2018.01.003

M3 - Article

AN - SCOPUS:85044436623

VL - 17

SP - 25

EP - 29

JO - Sensing and Bio-Sensing Research

JF - Sensing and Bio-Sensing Research

SN - 2214-1804

ER -