Effectiveness of an ammonia-water mixture turbine system to hot water heat source

Takashi Suzuki, Hideki Noguchi, Yoshiharu Amano, Takumi Hashizume, Masashi Akiba, Yoshiaki Tanzawa, Akira Usui

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    1 Citation (Scopus)

    Abstract

    An ammonia-water mixture (AWM) turbine system, the so-called Waseda ammonia-water Mixture Turbine System (W-MTS), is described. Results of cycle simulation are discussed which show that the W-MTS is superior to the other simple Kalina cycles (KCS1 and KCS34) to pressurized hot water and steam as a latent and a sensible heat source at a temperature of 160°C.

    Original languageEnglish
    Title of host publicationAmerican Society of Mechanical Engineers, Power Division (Publication) PWR
    Place of PublicationFairfield, NJ, United States
    PublisherASME
    Volume34
    Publication statusPublished - 1999
    EventThe 1999 International Joint Power Generation Conference and Exhibition and ICOPE '99 - Burlingame, CA, USA
    Duration: 1999 Jul 251999 Jul 28

    Other

    OtherThe 1999 International Joint Power Generation Conference and Exhibition and ICOPE '99
    CityBurlingame, CA, USA
    Period99/7/2599/7/28

    Fingerprint

    Ammonia
    Turbines
    Water
    Steam
    Hot Temperature
    Temperature

    ASJC Scopus subject areas

    • Nuclear Energy and Engineering
    • Mechanical Engineering

    Cite this

    Suzuki, T., Noguchi, H., Amano, Y., Hashizume, T., Akiba, M., Tanzawa, Y., & Usui, A. (1999). Effectiveness of an ammonia-water mixture turbine system to hot water heat source. In American Society of Mechanical Engineers, Power Division (Publication) PWR (Vol. 34). Fairfield, NJ, United States: ASME.

    Effectiveness of an ammonia-water mixture turbine system to hot water heat source. / Suzuki, Takashi; Noguchi, Hideki; Amano, Yoshiharu; Hashizume, Takumi; Akiba, Masashi; Tanzawa, Yoshiaki; Usui, Akira.

    American Society of Mechanical Engineers, Power Division (Publication) PWR. Vol. 34 Fairfield, NJ, United States : ASME, 1999.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Suzuki, T, Noguchi, H, Amano, Y, Hashizume, T, Akiba, M, Tanzawa, Y & Usui, A 1999, Effectiveness of an ammonia-water mixture turbine system to hot water heat source. in American Society of Mechanical Engineers, Power Division (Publication) PWR. vol. 34, ASME, Fairfield, NJ, United States, The 1999 International Joint Power Generation Conference and Exhibition and ICOPE '99, Burlingame, CA, USA, 99/7/25.
    Suzuki T, Noguchi H, Amano Y, Hashizume T, Akiba M, Tanzawa Y et al. Effectiveness of an ammonia-water mixture turbine system to hot water heat source. In American Society of Mechanical Engineers, Power Division (Publication) PWR. Vol. 34. Fairfield, NJ, United States: ASME. 1999
    Suzuki, Takashi ; Noguchi, Hideki ; Amano, Yoshiharu ; Hashizume, Takumi ; Akiba, Masashi ; Tanzawa, Yoshiaki ; Usui, Akira. / Effectiveness of an ammonia-water mixture turbine system to hot water heat source. American Society of Mechanical Engineers, Power Division (Publication) PWR. Vol. 34 Fairfield, NJ, United States : ASME, 1999.
    @inproceedings{3ec725bb324d4e4d803f89497f73c898,
    title = "Effectiveness of an ammonia-water mixture turbine system to hot water heat source",
    abstract = "An ammonia-water mixture (AWM) turbine system, the so-called Waseda ammonia-water Mixture Turbine System (W-MTS), is described. Results of cycle simulation are discussed which show that the W-MTS is superior to the other simple Kalina cycles (KCS1 and KCS34) to pressurized hot water and steam as a latent and a sensible heat source at a temperature of 160°C.",
    author = "Takashi Suzuki and Hideki Noguchi and Yoshiharu Amano and Takumi Hashizume and Masashi Akiba and Yoshiaki Tanzawa and Akira Usui",
    year = "1999",
    language = "English",
    volume = "34",
    booktitle = "American Society of Mechanical Engineers, Power Division (Publication) PWR",
    publisher = "ASME",

    }

    TY - GEN

    T1 - Effectiveness of an ammonia-water mixture turbine system to hot water heat source

    AU - Suzuki, Takashi

    AU - Noguchi, Hideki

    AU - Amano, Yoshiharu

    AU - Hashizume, Takumi

    AU - Akiba, Masashi

    AU - Tanzawa, Yoshiaki

    AU - Usui, Akira

    PY - 1999

    Y1 - 1999

    N2 - An ammonia-water mixture (AWM) turbine system, the so-called Waseda ammonia-water Mixture Turbine System (W-MTS), is described. Results of cycle simulation are discussed which show that the W-MTS is superior to the other simple Kalina cycles (KCS1 and KCS34) to pressurized hot water and steam as a latent and a sensible heat source at a temperature of 160°C.

    AB - An ammonia-water mixture (AWM) turbine system, the so-called Waseda ammonia-water Mixture Turbine System (W-MTS), is described. Results of cycle simulation are discussed which show that the W-MTS is superior to the other simple Kalina cycles (KCS1 and KCS34) to pressurized hot water and steam as a latent and a sensible heat source at a temperature of 160°C.

    UR - http://www.scopus.com/inward/record.url?scp=0343878832&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0343878832&partnerID=8YFLogxK

    M3 - Conference contribution

    VL - 34

    BT - American Society of Mechanical Engineers, Power Division (Publication) PWR

    PB - ASME

    CY - Fairfield, NJ, United States

    ER -