Electrical properties of thermoplastic polyimide

Seiichi Takei, Yasuhiro Tanabe, Yoshimichi Ohki

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    2 Citations (Scopus)

    Abstract

    Conduction process of thermoplastic polyimide has examined. The as-received sample shows a current with a peak at approximately 230 °C even when any poling bias has been applied. However, this spontaneous current disappears if the measurement is repeated. Conduction current decreases if the sample was heat-treated. It is considered that impurities such as K and Na remaining in the sample are responsible for the current peak or the spontaneous current.

    Original languageEnglish
    Title of host publicationIEEE International Conference on Conduction & Breakdown in Solid Dielectrics
    Place of PublicationPiscataway, NJ, United States
    PublisherIEEE
    Pages349-350
    Number of pages2
    Publication statusPublished - 1998
    EventProceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics - Vasteras, Sweden
    Duration: 1998 Jun 221998 Jun 25

    Other

    OtherProceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics
    CityVasteras, Sweden
    Period98/6/2298/6/25

    Fingerprint

    Polyimides
    Thermoplastics
    Electric properties
    Impurities
    Hot Temperature

    ASJC Scopus subject areas

    • Engineering(all)

    Cite this

    Takei, S., Tanabe, Y., & Ohki, Y. (1998). Electrical properties of thermoplastic polyimide. In IEEE International Conference on Conduction & Breakdown in Solid Dielectrics (pp. 349-350). Piscataway, NJ, United States: IEEE.

    Electrical properties of thermoplastic polyimide. / Takei, Seiichi; Tanabe, Yasuhiro; Ohki, Yoshimichi.

    IEEE International Conference on Conduction & Breakdown in Solid Dielectrics. Piscataway, NJ, United States : IEEE, 1998. p. 349-350.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Takei, S, Tanabe, Y & Ohki, Y 1998, Electrical properties of thermoplastic polyimide. in IEEE International Conference on Conduction & Breakdown in Solid Dielectrics. IEEE, Piscataway, NJ, United States, pp. 349-350, Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics, Vasteras, Sweden, 98/6/22.
    Takei S, Tanabe Y, Ohki Y. Electrical properties of thermoplastic polyimide. In IEEE International Conference on Conduction & Breakdown in Solid Dielectrics. Piscataway, NJ, United States: IEEE. 1998. p. 349-350
    Takei, Seiichi ; Tanabe, Yasuhiro ; Ohki, Yoshimichi. / Electrical properties of thermoplastic polyimide. IEEE International Conference on Conduction & Breakdown in Solid Dielectrics. Piscataway, NJ, United States : IEEE, 1998. pp. 349-350
    @inproceedings{e3b51701017c4374849dafaa9040b25f,
    title = "Electrical properties of thermoplastic polyimide",
    abstract = "Conduction process of thermoplastic polyimide has examined. The as-received sample shows a current with a peak at approximately 230 °C even when any poling bias has been applied. However, this spontaneous current disappears if the measurement is repeated. Conduction current decreases if the sample was heat-treated. It is considered that impurities such as K and Na remaining in the sample are responsible for the current peak or the spontaneous current.",
    author = "Seiichi Takei and Yasuhiro Tanabe and Yoshimichi Ohki",
    year = "1998",
    language = "English",
    pages = "349--350",
    booktitle = "IEEE International Conference on Conduction & Breakdown in Solid Dielectrics",
    publisher = "IEEE",

    }

    TY - GEN

    T1 - Electrical properties of thermoplastic polyimide

    AU - Takei, Seiichi

    AU - Tanabe, Yasuhiro

    AU - Ohki, Yoshimichi

    PY - 1998

    Y1 - 1998

    N2 - Conduction process of thermoplastic polyimide has examined. The as-received sample shows a current with a peak at approximately 230 °C even when any poling bias has been applied. However, this spontaneous current disappears if the measurement is repeated. Conduction current decreases if the sample was heat-treated. It is considered that impurities such as K and Na remaining in the sample are responsible for the current peak or the spontaneous current.

    AB - Conduction process of thermoplastic polyimide has examined. The as-received sample shows a current with a peak at approximately 230 °C even when any poling bias has been applied. However, this spontaneous current disappears if the measurement is repeated. Conduction current decreases if the sample was heat-treated. It is considered that impurities such as K and Na remaining in the sample are responsible for the current peak or the spontaneous current.

    UR - http://www.scopus.com/inward/record.url?scp=0032301105&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0032301105&partnerID=8YFLogxK

    M3 - Conference contribution

    SP - 349

    EP - 350

    BT - IEEE International Conference on Conduction & Breakdown in Solid Dielectrics

    PB - IEEE

    CY - Piscataway, NJ, United States

    ER -