Electron energy spectrometer of retarding field type

H. Hori, N. Maeda, Naoto Kobayashi, M. Sakisaka

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

An electron energy spectrometer of straight and two-stage retarding field type is presented, where the electric potential on the axis is chosen symmetric as F{cyrillic}(z) ∝ exp (α|z|/L) for -L≤ z≤L (α: positive eigenvalue) in each stage. According to the solution of the trajectory, the spectrometer is so designed as to filter electrons with double focusing. The energy resolution of a compact spectrometer is 2-3 eV in the range of 50-2000 eV and that of a longer one is less than 1 eV. The spectrometers have worked satisfactorily in measuring Auger electrons emitted from ion-atom and electron-atom collisions.

Original languageEnglish
Pages (from-to)135-141
Number of pages7
JournalNuclear Instruments and Methods
Volume130
Issue number1
DOIs
Publication statusPublished - 1975 Dec 1
Externally publishedYes

Fingerprint

Spectrometers
Electrons
Atoms
Trajectories
Ions
Electric potential

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Electron energy spectrometer of retarding field type. / Hori, H.; Maeda, N.; Kobayashi, Naoto; Sakisaka, M.

In: Nuclear Instruments and Methods, Vol. 130, No. 1, 01.12.1975, p. 135-141.

Research output: Contribution to journalArticle

Hori, H. ; Maeda, N. ; Kobayashi, Naoto ; Sakisaka, M. / Electron energy spectrometer of retarding field type. In: Nuclear Instruments and Methods. 1975 ; Vol. 130, No. 1. pp. 135-141.
@article{028965d68d4742ce9bc09dfd4a44ccef,
title = "Electron energy spectrometer of retarding field type",
abstract = "An electron energy spectrometer of straight and two-stage retarding field type is presented, where the electric potential on the axis is chosen symmetric as F{cyrillic}(z) ∝ exp (α|z|/L) for -L≤ z≤L (α: positive eigenvalue) in each stage. According to the solution of the trajectory, the spectrometer is so designed as to filter electrons with double focusing. The energy resolution of a compact spectrometer is 2-3 eV in the range of 50-2000 eV and that of a longer one is less than 1 eV. The spectrometers have worked satisfactorily in measuring Auger electrons emitted from ion-atom and electron-atom collisions.",
author = "H. Hori and N. Maeda and Naoto Kobayashi and M. Sakisaka",
year = "1975",
month = "12",
day = "1",
doi = "10.1016/0029-554X(75)90165-2",
language = "English",
volume = "130",
pages = "135--141",
journal = "Nuclear Instruments and Methods",
issn = "0029-554X",
publisher = "Elsevier BV",
number = "1",

}

TY - JOUR

T1 - Electron energy spectrometer of retarding field type

AU - Hori, H.

AU - Maeda, N.

AU - Kobayashi, Naoto

AU - Sakisaka, M.

PY - 1975/12/1

Y1 - 1975/12/1

N2 - An electron energy spectrometer of straight and two-stage retarding field type is presented, where the electric potential on the axis is chosen symmetric as F{cyrillic}(z) ∝ exp (α|z|/L) for -L≤ z≤L (α: positive eigenvalue) in each stage. According to the solution of the trajectory, the spectrometer is so designed as to filter electrons with double focusing. The energy resolution of a compact spectrometer is 2-3 eV in the range of 50-2000 eV and that of a longer one is less than 1 eV. The spectrometers have worked satisfactorily in measuring Auger electrons emitted from ion-atom and electron-atom collisions.

AB - An electron energy spectrometer of straight and two-stage retarding field type is presented, where the electric potential on the axis is chosen symmetric as F{cyrillic}(z) ∝ exp (α|z|/L) for -L≤ z≤L (α: positive eigenvalue) in each stage. According to the solution of the trajectory, the spectrometer is so designed as to filter electrons with double focusing. The energy resolution of a compact spectrometer is 2-3 eV in the range of 50-2000 eV and that of a longer one is less than 1 eV. The spectrometers have worked satisfactorily in measuring Auger electrons emitted from ion-atom and electron-atom collisions.

UR - http://www.scopus.com/inward/record.url?scp=0016599892&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0016599892&partnerID=8YFLogxK

U2 - 10.1016/0029-554X(75)90165-2

DO - 10.1016/0029-554X(75)90165-2

M3 - Article

AN - SCOPUS:0016599892

VL - 130

SP - 135

EP - 141

JO - Nuclear Instruments and Methods

JF - Nuclear Instruments and Methods

SN - 0029-554X

IS - 1

ER -