EVALUATION OF IMAGING CAPABILITY OF ROD-LENS-ARRAY USING OPTICAL FILTERING TECHNIQUE.

Katsuto Sumi, Shinichi Komatsu, Hitoshi Ohzu

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    1 Citation (Scopus)

    Abstract

    The gradient index (GRIN) rod-lens-array is now being widely used as a compact imaging device, e. g. , for a low cost plain paper copier because of its short focal length, high numerical aperture and small and light body. For the evaluation of the imaging capability of the GRIN rod-lens-array, it is useful to measure the modulation transfer function (MTF) in its entire image plane as well as that of each element lens composing the rod-lens-array. We propose a new method for the evaluation which is performed by speckle double exposure technique combined with conventional optical filtering.

    Original languageEnglish
    Title of host publicationUnknown Host Publication Title
    EditorsHitoshi Ohzu
    Place of PublicationDelft, Ne
    PublisherInt Commission for Optics, Organizing Committee
    Pages574-575
    Number of pages2
    Publication statusPublished - 1984