EVALUATION OF IMAGING CAPABILITY OF ROD-LENS-ARRAY USING OPTICAL FILTERING TECHNIQUE.

Katsuto Sumi, Shinichi Komatsu, Hitoshi Ohzu

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    1 Citation (Scopus)

    Abstract

    The gradient index (GRIN) rod-lens-array is now being widely used as a compact imaging device, e. g. , for a low cost plain paper copier because of its short focal length, high numerical aperture and small and light body. For the evaluation of the imaging capability of the GRIN rod-lens-array, it is useful to measure the modulation transfer function (MTF) in its entire image plane as well as that of each element lens composing the rod-lens-array. We propose a new method for the evaluation which is performed by speckle double exposure technique combined with conventional optical filtering.

    Original languageEnglish
    Title of host publicationUnknown Host Publication Title
    EditorsHitoshi Ohzu
    Place of PublicationDelft, Ne
    PublisherInt Commission for Optics, Organizing Committee
    Pages574-575
    Number of pages2
    Publication statusPublished - 1984

    Fingerprint

    Lenses
    Imaging techniques
    Optical transfer function
    Speckle
    Costs

    ASJC Scopus subject areas

    • Engineering(all)

    Cite this

    Sumi, K., Komatsu, S., & Ohzu, H. (1984). EVALUATION OF IMAGING CAPABILITY OF ROD-LENS-ARRAY USING OPTICAL FILTERING TECHNIQUE. In H. Ohzu (Ed.), Unknown Host Publication Title (pp. 574-575). Delft, Ne: Int Commission for Optics, Organizing Committee.

    EVALUATION OF IMAGING CAPABILITY OF ROD-LENS-ARRAY USING OPTICAL FILTERING TECHNIQUE. / Sumi, Katsuto; Komatsu, Shinichi; Ohzu, Hitoshi.

    Unknown Host Publication Title. ed. / Hitoshi Ohzu. Delft, Ne : Int Commission for Optics, Organizing Committee, 1984. p. 574-575.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Sumi, K, Komatsu, S & Ohzu, H 1984, EVALUATION OF IMAGING CAPABILITY OF ROD-LENS-ARRAY USING OPTICAL FILTERING TECHNIQUE. in H Ohzu (ed.), Unknown Host Publication Title. Int Commission for Optics, Organizing Committee, Delft, Ne, pp. 574-575.
    Sumi K, Komatsu S, Ohzu H. EVALUATION OF IMAGING CAPABILITY OF ROD-LENS-ARRAY USING OPTICAL FILTERING TECHNIQUE. In Ohzu H, editor, Unknown Host Publication Title. Delft, Ne: Int Commission for Optics, Organizing Committee. 1984. p. 574-575
    Sumi, Katsuto ; Komatsu, Shinichi ; Ohzu, Hitoshi. / EVALUATION OF IMAGING CAPABILITY OF ROD-LENS-ARRAY USING OPTICAL FILTERING TECHNIQUE. Unknown Host Publication Title. editor / Hitoshi Ohzu. Delft, Ne : Int Commission for Optics, Organizing Committee, 1984. pp. 574-575
    @inproceedings{e0c5dee623bf48459b4f852aacc937cb,
    title = "EVALUATION OF IMAGING CAPABILITY OF ROD-LENS-ARRAY USING OPTICAL FILTERING TECHNIQUE.",
    abstract = "The gradient index (GRIN) rod-lens-array is now being widely used as a compact imaging device, e. g. , for a low cost plain paper copier because of its short focal length, high numerical aperture and small and light body. For the evaluation of the imaging capability of the GRIN rod-lens-array, it is useful to measure the modulation transfer function (MTF) in its entire image plane as well as that of each element lens composing the rod-lens-array. We propose a new method for the evaluation which is performed by speckle double exposure technique combined with conventional optical filtering.",
    author = "Katsuto Sumi and Shinichi Komatsu and Hitoshi Ohzu",
    year = "1984",
    language = "English",
    pages = "574--575",
    editor = "Hitoshi Ohzu",
    booktitle = "Unknown Host Publication Title",
    publisher = "Int Commission for Optics, Organizing Committee",

    }

    TY - GEN

    T1 - EVALUATION OF IMAGING CAPABILITY OF ROD-LENS-ARRAY USING OPTICAL FILTERING TECHNIQUE.

    AU - Sumi, Katsuto

    AU - Komatsu, Shinichi

    AU - Ohzu, Hitoshi

    PY - 1984

    Y1 - 1984

    N2 - The gradient index (GRIN) rod-lens-array is now being widely used as a compact imaging device, e. g. , for a low cost plain paper copier because of its short focal length, high numerical aperture and small and light body. For the evaluation of the imaging capability of the GRIN rod-lens-array, it is useful to measure the modulation transfer function (MTF) in its entire image plane as well as that of each element lens composing the rod-lens-array. We propose a new method for the evaluation which is performed by speckle double exposure technique combined with conventional optical filtering.

    AB - The gradient index (GRIN) rod-lens-array is now being widely used as a compact imaging device, e. g. , for a low cost plain paper copier because of its short focal length, high numerical aperture and small and light body. For the evaluation of the imaging capability of the GRIN rod-lens-array, it is useful to measure the modulation transfer function (MTF) in its entire image plane as well as that of each element lens composing the rod-lens-array. We propose a new method for the evaluation which is performed by speckle double exposure technique combined with conventional optical filtering.

    UR - http://www.scopus.com/inward/record.url?scp=0021656729&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0021656729&partnerID=8YFLogxK

    M3 - Conference contribution

    AN - SCOPUS:0021656729

    SP - 574

    EP - 575

    BT - Unknown Host Publication Title

    A2 - Ohzu, Hitoshi

    PB - Int Commission for Optics, Organizing Committee

    CY - Delft, Ne

    ER -