    The purpose of this study is to collect basic data required for the development of mercury heat pipes operating in the temperature range of 623 to 873 K, which will be used in the industrial field. For this purpose, three kinds of mercury heat pipes were made of stainless tubing (SUS316L) 25 mm in diameter and 1000 mm in length. As a result of these tests, it is concluded that the mercury heat pipe exhibits good performance except during startup, but the material compatibility between the stainless steel tubing and mercury is not very good.

    Original languageEnglish
    Pages (from-to)39-46
    Number of pages8
    JournalExperimental Thermal and Fluid Science
    Volume9
    Issue number1
    DOIs
    Publication statusPublished - 1994

    Fingerprint

    Heat pipes
    Mercury
    Tubing
    Stainless Steel
    Stainless steel
    Temperature

    Keywords

    • boiling and condensation curve
    • corrosion
    • deposit layer
    • diffusion layer
    • material compatibility
    • mercury heat pipe

    ASJC Scopus subject areas

    • Fluid Flow and Transfer Processes
    • Mechanical Engineering

    Cite this

    Experimental study of mercury heat pipe. / Yamamoto, Tadashi; Nagata, Katsuya; Katsuta, Masafumi; Ikeda, Yoshio.

    In: Experimental Thermal and Fluid Science, Vol. 9, No. 1, 1994, p. 39-46.

    Research output: Contribution to journalArticle

    Yamamoto, Tadashi ; Nagata, Katsuya ; Katsuta, Masafumi ; Ikeda, Yoshio. / Experimental study of mercury heat pipe. In: Experimental Thermal and Fluid Science. 1994 ; Vol. 9, No. 1. pp. 39-46.
    @article{9cbc46991f7643e3be94a33019255383,
    title = "Experimental study of mercury heat pipe",
    abstract = "The purpose of this study is to collect basic data required for the development of mercury heat pipes operating in the temperature range of 623 to 873 K, which will be used in the industrial field. For this purpose, three kinds of mercury heat pipes were made of stainless tubing (SUS316L) 25 mm in diameter and 1000 mm in length. As a result of these tests, it is concluded that the mercury heat pipe exhibits good performance except during startup, but the material compatibility between the stainless steel tubing and mercury is not very good.",
    keywords = "boiling and condensation curve, corrosion, deposit layer, diffusion layer, material compatibility, mercury heat pipe",
    author = "Tadashi Yamamoto and Katsuya Nagata and Masafumi Katsuta and Yoshio Ikeda",
    year = "1994",
    doi = "10.1016/0894-1777(94)90006-X",
    language = "English",
    volume = "9",
    pages = "39--46",
    journal = "Experimental Thermal and Fluid Science",
    issn = "0894-1777",
    publisher = "Elsevier Inc.",
    number = "1",

    }

    TY - JOUR

    T1 - Experimental study of mercury heat pipe

    AU - Yamamoto, Tadashi

    AU - Nagata, Katsuya

    AU - Katsuta, Masafumi

    AU - Ikeda, Yoshio

    PY - 1994

    Y1 - 1994

    N2 - The purpose of this study is to collect basic data required for the development of mercury heat pipes operating in the temperature range of 623 to 873 K, which will be used in the industrial field. For this purpose, three kinds of mercury heat pipes were made of stainless tubing (SUS316L) 25 mm in diameter and 1000 mm in length. As a result of these tests, it is concluded that the mercury heat pipe exhibits good performance except during startup, but the material compatibility between the stainless steel tubing and mercury is not very good.

    AB - The purpose of this study is to collect basic data required for the development of mercury heat pipes operating in the temperature range of 623 to 873 K, which will be used in the industrial field. For this purpose, three kinds of mercury heat pipes were made of stainless tubing (SUS316L) 25 mm in diameter and 1000 mm in length. As a result of these tests, it is concluded that the mercury heat pipe exhibits good performance except during startup, but the material compatibility between the stainless steel tubing and mercury is not very good.

    KW - boiling and condensation curve

    KW - corrosion

    KW - deposit layer

    KW - diffusion layer

    KW - material compatibility

    KW - mercury heat pipe

    UR - http://www.scopus.com/inward/record.url?scp=0028466009&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0028466009&partnerID=8YFLogxK

    U2 - 10.1016/0894-1777(94)90006-X

    DO - 10.1016/0894-1777(94)90006-X

    M3 - Article

    AN - SCOPUS:0028466009

    VL - 9

    SP - 39

    EP - 46

    JO - Experimental Thermal and Fluid Science

    JF - Experimental Thermal and Fluid Science

    SN - 0894-1777

    IS - 1

    ER -