TY - JOUR
T1 - Four-dimensional model of the lower extremity after total hip arthroplasty
AU - Otake, Yoshito
AU - Suzuki, Naoki
AU - Hattori, Asaki
AU - Hagio, Keisuke
AU - Sugano, Nobuhiko
AU - Yonenobu, Kazuo
AU - Ochi, Takahiro
N1 - Funding Information:
This study was supported by the Future Pioneering Study Promotion Project of the Japan Science Promotion Council entitled, “The development of the robotic system in the area of the science of surgery”
PY - 2005/12
Y1 - 2005/12
N2 - We have developed a four-dimensional (4D) model of the lower extremities after total hip arthroplasty in patients. The model can aid in preventing complications such as dislocation and wearing of the sliding surface. The skeletal structure and implant alignment were obtained from CT data. We applied registration method using CAD data to estimate accurate implant alignment from scattered CT data. The reconstructed three-dimensional (3D) skeletal model was combined with motion capture data that were acquired by an optical tracking system. We displayed the patient's skeletal movement and analyzed several parameters that relate to complications. The patient's skeletal model was superimposed onto video footage that was taken by a synchronized and calibrated digital video camera. For validation of the measurement error in this system, we used open MRI to evaluate the relative movement between skin markers and bones. This system visually represents not only the 3D anatomical structure, but also 4D dynamic functions that include the time sequential transitions of components and their positions. The open MRI results indicated that the average error in hip angle was within 5° for each static posture. This system enables clinicians to analyze patient's motions on the basis of individual differences. We found that our system was an effective tool in providing precise guidance of daily postoperative motions that was individualized for each patient. This system will be applicable for surgical planning, assessment of postoperative activities, and the development of new surgical techniques, materials, and prosthetic designs.
AB - We have developed a four-dimensional (4D) model of the lower extremities after total hip arthroplasty in patients. The model can aid in preventing complications such as dislocation and wearing of the sliding surface. The skeletal structure and implant alignment were obtained from CT data. We applied registration method using CAD data to estimate accurate implant alignment from scattered CT data. The reconstructed three-dimensional (3D) skeletal model was combined with motion capture data that were acquired by an optical tracking system. We displayed the patient's skeletal movement and analyzed several parameters that relate to complications. The patient's skeletal model was superimposed onto video footage that was taken by a synchronized and calibrated digital video camera. For validation of the measurement error in this system, we used open MRI to evaluate the relative movement between skin markers and bones. This system visually represents not only the 3D anatomical structure, but also 4D dynamic functions that include the time sequential transitions of components and their positions. The open MRI results indicated that the average error in hip angle was within 5° for each static posture. This system enables clinicians to analyze patient's motions on the basis of individual differences. We found that our system was an effective tool in providing precise guidance of daily postoperative motions that was individualized for each patient. This system will be applicable for surgical planning, assessment of postoperative activities, and the development of new surgical techniques, materials, and prosthetic designs.
KW - Computer simulation
KW - Dislocation
KW - Four-dimensional human model
KW - Motion analysis
KW - Total hip arthroplasty
UR - http://www.scopus.com/inward/record.url?scp=26444618521&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=26444618521&partnerID=8YFLogxK
U2 - 10.1016/j.jbiomech.2004.10.023
DO - 10.1016/j.jbiomech.2004.10.023
M3 - Article
C2 - 16214487
AN - SCOPUS:26444618521
SN - 0021-9290
VL - 38
SP - 2397
EP - 2405
JO - Journal of Biomechanics
JF - Journal of Biomechanics
IS - 12
ER -