Gilbert damping for various Ni80Fe20 thin films investigated using all-optical pump-probe detection and ferromagnetic resonance

Shigemi Mizukami, Hiroyuki Abe, Daisuke Watanabe, Mikihiko Oogane, Yasuo Ando, Terunobu Miyazaki

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

All-optical pump-probe detection of magnetization precession has been performed to investigate Gilbert damping in several types of Ni 80Fe20 films. The frequency and decay time of magnetization precession depended on pump fluence. At low pump fluence, Gilbert damping constants, derived from the magnetic field dependence on frequency and decay time of magnetization precession, were identical to values obtained from X-band ferromagnetic resonance within the experimental errors.

Original languageEnglish
Pages (from-to)1213011-1213013
Number of pages3
JournalApplied Physics Express
Volume1
Issue number12
DOIs
Publication statusPublished - 2008 Dec
Externally publishedYes

Fingerprint

Ferromagnetic resonance
ferromagnetic resonance
precession
Magnetization
Damping
damping
Pumps
pumps
Thin films
magnetization
probes
fluence
thin films
decay
superhigh frequencies
Magnetic fields
magnetic fields

ASJC Scopus subject areas

  • Engineering(all)
  • Physics and Astronomy(all)

Cite this

Gilbert damping for various Ni80Fe20 thin films investigated using all-optical pump-probe detection and ferromagnetic resonance. / Mizukami, Shigemi; Abe, Hiroyuki; Watanabe, Daisuke; Oogane, Mikihiko; Ando, Yasuo; Miyazaki, Terunobu.

In: Applied Physics Express, Vol. 1, No. 12, 12.2008, p. 1213011-1213013.

Research output: Contribution to journalArticle

Mizukami, Shigemi ; Abe, Hiroyuki ; Watanabe, Daisuke ; Oogane, Mikihiko ; Ando, Yasuo ; Miyazaki, Terunobu. / Gilbert damping for various Ni80Fe20 thin films investigated using all-optical pump-probe detection and ferromagnetic resonance. In: Applied Physics Express. 2008 ; Vol. 1, No. 12. pp. 1213011-1213013.
@article{0f2ab2b837954254a4192b9dc942a385,
title = "Gilbert damping for various Ni80Fe20 thin films investigated using all-optical pump-probe detection and ferromagnetic resonance",
abstract = "All-optical pump-probe detection of magnetization precession has been performed to investigate Gilbert damping in several types of Ni 80Fe20 films. The frequency and decay time of magnetization precession depended on pump fluence. At low pump fluence, Gilbert damping constants, derived from the magnetic field dependence on frequency and decay time of magnetization precession, were identical to values obtained from X-band ferromagnetic resonance within the experimental errors.",
author = "Shigemi Mizukami and Hiroyuki Abe and Daisuke Watanabe and Mikihiko Oogane and Yasuo Ando and Terunobu Miyazaki",
year = "2008",
month = "12",
doi = "10.1143/APEX.1.121301",
language = "English",
volume = "1",
pages = "1213011--1213013",
journal = "Applied Physics Express",
issn = "1882-0778",
publisher = "Japan Society of Applied Physics",
number = "12",

}

TY - JOUR

T1 - Gilbert damping for various Ni80Fe20 thin films investigated using all-optical pump-probe detection and ferromagnetic resonance

AU - Mizukami, Shigemi

AU - Abe, Hiroyuki

AU - Watanabe, Daisuke

AU - Oogane, Mikihiko

AU - Ando, Yasuo

AU - Miyazaki, Terunobu

PY - 2008/12

Y1 - 2008/12

N2 - All-optical pump-probe detection of magnetization precession has been performed to investigate Gilbert damping in several types of Ni 80Fe20 films. The frequency and decay time of magnetization precession depended on pump fluence. At low pump fluence, Gilbert damping constants, derived from the magnetic field dependence on frequency and decay time of magnetization precession, were identical to values obtained from X-band ferromagnetic resonance within the experimental errors.

AB - All-optical pump-probe detection of magnetization precession has been performed to investigate Gilbert damping in several types of Ni 80Fe20 films. The frequency and decay time of magnetization precession depended on pump fluence. At low pump fluence, Gilbert damping constants, derived from the magnetic field dependence on frequency and decay time of magnetization precession, were identical to values obtained from X-band ferromagnetic resonance within the experimental errors.

UR - http://www.scopus.com/inward/record.url?scp=57649183514&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=57649183514&partnerID=8YFLogxK

U2 - 10.1143/APEX.1.121301

DO - 10.1143/APEX.1.121301

M3 - Article

AN - SCOPUS:57649183514

VL - 1

SP - 1213011

EP - 1213013

JO - Applied Physics Express

JF - Applied Physics Express

SN - 1882-0778

IS - 12

ER -