    We develop the micro chamber for real-time monitoring of living cell. It is integrated with an extremely low dead volume sample injector. The chamber was fabricated by the combination of isotropic etching and deep trench etching using CCP-RIE and ICP-RIE. The reproducible sample injection of the order of 1 nL is performed. Biological cell culture of HeLa is also demonstrated in a prototype device.

    Original languageEnglish
    Title of host publicationTRANSDUCERS 2003 - 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers
    PublisherInstitute of Electrical and Electronics Engineers Inc.
    Pages288-291
    Number of pages4
    Volume1
    ISBN (Print)0780377311, 9780780377318
    DOIs
    Publication statusPublished - 2003
    Event12th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS 2003 - Digest of Technical Papers - Boston, United States
    Duration: 2003 Jun 82003 Jun 12

    Other

    Other12th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS 2003 - Digest of Technical Papers
    CountryUnited States
    CityBoston
    Period03/6/803/6/12

    Fingerprint

    Reactive ion etching
    Etching
    Cells
    Cell culture
    Monitoring

    Keywords

    • Biological cells
    • Bonding
    • Etching
    • Filters
    • Laboratories
    • Monitoring
    • Polymers
    • Prototypes
    • System-on-a-chip
    • Valves

    ASJC Scopus subject areas

    • Electrical and Electronic Engineering

    Cite this

    Kanai, M., Abe, H., Munaka, T., Fujiyama, Y., Uchida, D., Yamayoshi, A., ... Shoji, S. (2003). Integrated micro chamber for living cell analysis with negligible dead volume sample injector. In TRANSDUCERS 2003 - 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers (Vol. 1, pp. 288-291). [1215309] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/SENSOR.2003.1215309

    Integrated micro chamber for living cell analysis with negligible dead volume sample injector. / Kanai, M.; Abe, H.; Munaka, T.; Fujiyama, Y.; Uchida, D.; Yamayoshi, A.; Nakanishi, H.; Murakami, A.; Shoji, Shuichi.

    TRANSDUCERS 2003 - 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. Vol. 1 Institute of Electrical and Electronics Engineers Inc., 2003. p. 288-291 1215309.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Kanai, M, Abe, H, Munaka, T, Fujiyama, Y, Uchida, D, Yamayoshi, A, Nakanishi, H, Murakami, A & Shoji, S 2003, Integrated micro chamber for living cell analysis with negligible dead volume sample injector. in TRANSDUCERS 2003 - 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. vol. 1, 1215309, Institute of Electrical and Electronics Engineers Inc., pp. 288-291, 12th International Conference on Solid-State Sensors, Actuators and Microsystems, TRANSDUCERS 2003 - Digest of Technical Papers, Boston, United States, 03/6/8. https://doi.org/10.1109/SENSOR.2003.1215309
    Kanai M, Abe H, Munaka T, Fujiyama Y, Uchida D, Yamayoshi A et al. Integrated micro chamber for living cell analysis with negligible dead volume sample injector. In TRANSDUCERS 2003 - 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. Vol. 1. Institute of Electrical and Electronics Engineers Inc. 2003. p. 288-291. 1215309 https://doi.org/10.1109/SENSOR.2003.1215309
    Kanai, M. ; Abe, H. ; Munaka, T. ; Fujiyama, Y. ; Uchida, D. ; Yamayoshi, A. ; Nakanishi, H. ; Murakami, A. ; Shoji, Shuichi. / Integrated micro chamber for living cell analysis with negligible dead volume sample injector. TRANSDUCERS 2003 - 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers. Vol. 1 Institute of Electrical and Electronics Engineers Inc., 2003. pp. 288-291
    @inproceedings{8e6438c8f8da4292906cd3378a84dd5c,
    title = "Integrated micro chamber for living cell analysis with negligible dead volume sample injector",
    abstract = "We develop the micro chamber for real-time monitoring of living cell. It is integrated with an extremely low dead volume sample injector. The chamber was fabricated by the combination of isotropic etching and deep trench etching using CCP-RIE and ICP-RIE. The reproducible sample injection of the order of 1 nL is performed. Biological cell culture of HeLa is also demonstrated in a prototype device.",
    keywords = "Biological cells, Bonding, Etching, Filters, Laboratories, Monitoring, Polymers, Prototypes, System-on-a-chip, Valves",
    author = "M. Kanai and H. Abe and T. Munaka and Y. Fujiyama and D. Uchida and A. Yamayoshi and H. Nakanishi and A. Murakami and Shuichi Shoji",
    year = "2003",
    doi = "10.1109/SENSOR.2003.1215309",
    language = "English",
    isbn = "0780377311",
    volume = "1",
    pages = "288--291",
    booktitle = "TRANSDUCERS 2003 - 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers",
    publisher = "Institute of Electrical and Electronics Engineers Inc.",

    }

    TY - GEN

    T1 - Integrated micro chamber for living cell analysis with negligible dead volume sample injector

    AU - Kanai, M.

    AU - Abe, H.

    AU - Munaka, T.

    AU - Fujiyama, Y.

    AU - Uchida, D.

    AU - Yamayoshi, A.

    AU - Nakanishi, H.

    AU - Murakami, A.

    AU - Shoji, Shuichi

    PY - 2003

    Y1 - 2003

    N2 - We develop the micro chamber for real-time monitoring of living cell. It is integrated with an extremely low dead volume sample injector. The chamber was fabricated by the combination of isotropic etching and deep trench etching using CCP-RIE and ICP-RIE. The reproducible sample injection of the order of 1 nL is performed. Biological cell culture of HeLa is also demonstrated in a prototype device.

    AB - We develop the micro chamber for real-time monitoring of living cell. It is integrated with an extremely low dead volume sample injector. The chamber was fabricated by the combination of isotropic etching and deep trench etching using CCP-RIE and ICP-RIE. The reproducible sample injection of the order of 1 nL is performed. Biological cell culture of HeLa is also demonstrated in a prototype device.

    KW - Biological cells

    KW - Bonding

    KW - Etching

    KW - Filters

    KW - Laboratories

    KW - Monitoring

    KW - Polymers

    KW - Prototypes

    KW - System-on-a-chip

    KW - Valves

    UR - http://www.scopus.com/inward/record.url?scp=10644226621&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=10644226621&partnerID=8YFLogxK

    U2 - 10.1109/SENSOR.2003.1215309

    DO - 10.1109/SENSOR.2003.1215309

    M3 - Conference contribution

    SN - 0780377311

    SN - 9780780377318

    VL - 1

    SP - 288

    EP - 291

    BT - TRANSDUCERS 2003 - 12th International Conference on Solid-State Sensors, Actuators and Microsystems, Digest of Technical Papers

    PB - Institute of Electrical and Electronics Engineers Inc.

    ER -