LOAD FREQUENCY CONTROL INCORPORATING TIME DELAY.

Kenji Okada, Goro Shirai, Ryuichi Yokoyama

    Research output: Contribution to journalArticle

    1 Citation (Scopus)

    Abstract

    When there is a computation delay in determining feedback gains, the incorporation of the time delay is necessary for the improvement of the dynamic responses (overshoot and settling time). The influences of the delay time on the responses are investigated using a two-area load frequency model, and a load-frequency control scheme is discussed that incorporates the computation delay time in the control law.

    Original languageEnglish
    Pages (from-to)968-969
    Number of pages2
    JournalProceedings of the IEEE
    Volume75
    Issue number7
    DOIs
    Publication statusPublished - 1987 Jul

    Fingerprint

    Time delay
    Dynamic response
    Feedback

    ASJC Scopus subject areas

    • Electrical and Electronic Engineering

    Cite this

    LOAD FREQUENCY CONTROL INCORPORATING TIME DELAY. / Okada, Kenji; Shirai, Goro; Yokoyama, Ryuichi.

    In: Proceedings of the IEEE, Vol. 75, No. 7, 07.1987, p. 968-969.

    Research output: Contribution to journalArticle

    Okada, K, Shirai, G & Yokoyama, R 1987, 'LOAD FREQUENCY CONTROL INCORPORATING TIME DELAY.', Proceedings of the IEEE, vol. 75, no. 7, pp. 968-969. https://doi.org/10.1109/PROC.1987.13834
    Okada, Kenji ; Shirai, Goro ; Yokoyama, Ryuichi. / LOAD FREQUENCY CONTROL INCORPORATING TIME DELAY. In: Proceedings of the IEEE. 1987 ; Vol. 75, No. 7. pp. 968-969.
    @article{77bb8e90fbe4401f84c57f9861acc581,
    title = "LOAD FREQUENCY CONTROL INCORPORATING TIME DELAY.",
    abstract = "When there is a computation delay in determining feedback gains, the incorporation of the time delay is necessary for the improvement of the dynamic responses (overshoot and settling time). The influences of the delay time on the responses are investigated using a two-area load frequency model, and a load-frequency control scheme is discussed that incorporates the computation delay time in the control law.",
    author = "Kenji Okada and Goro Shirai and Ryuichi Yokoyama",
    year = "1987",
    month = "7",
    doi = "10.1109/PROC.1987.13834",
    language = "English",
    volume = "75",
    pages = "968--969",
    journal = "Proceedings of the IEEE",
    issn = "0018-9219",
    publisher = "Institute of Electrical and Electronics Engineers Inc.",
    number = "7",

    }

    TY - JOUR

    T1 - LOAD FREQUENCY CONTROL INCORPORATING TIME DELAY.

    AU - Okada, Kenji

    AU - Shirai, Goro

    AU - Yokoyama, Ryuichi

    PY - 1987/7

    Y1 - 1987/7

    N2 - When there is a computation delay in determining feedback gains, the incorporation of the time delay is necessary for the improvement of the dynamic responses (overshoot and settling time). The influences of the delay time on the responses are investigated using a two-area load frequency model, and a load-frequency control scheme is discussed that incorporates the computation delay time in the control law.

    AB - When there is a computation delay in determining feedback gains, the incorporation of the time delay is necessary for the improvement of the dynamic responses (overshoot and settling time). The influences of the delay time on the responses are investigated using a two-area load frequency model, and a load-frequency control scheme is discussed that incorporates the computation delay time in the control law.

    UR - http://www.scopus.com/inward/record.url?scp=0023383082&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0023383082&partnerID=8YFLogxK

    U2 - 10.1109/PROC.1987.13834

    DO - 10.1109/PROC.1987.13834

    M3 - Article

    VL - 75

    SP - 968

    EP - 969

    JO - Proceedings of the IEEE

    JF - Proceedings of the IEEE

    SN - 0018-9219

    IS - 7

    ER -