Measurement of the lifetime of ionic vacancy by the cyclotron-MHD electrode

R. Aogaki, K. Motomura, A. Sugiyama, R. Morimoto, I. Mogi, M. Miura, M. Asanuma, Y. Oshikiri

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

With a new type of magnetohydrodynamic (MHD) electrode called cyclotron MHD electrode (CMHDE), the lifetime of ionic vacancy created in copper electrodeposition has been first measured. In a CMHDE, coaxial cylinders partly exposed as electrodes are placed vertically in an electrolytic solution under a vertical magnetic field, so that induced Lorentz force makes ionic vacancies circulate together with the solution along the circumferences. At low magnetic fields, ionic vacancies once created become extinct on the way of returning, whereas at high magnetic fields, they can come back to their initial birth points in enhanced velocities. By detecting the difference between these two states, we can measure the lifetime of ionic vacancy. At the same time, by changing the collision efficiency between created and returning vacancies, two reaction processes, i.e., the decay of ionic vacancy and the conversion to nanobubble can be analyzed. As a result, in the present case, it was concluded that the intrinsic lifetime of ionic vacancy is 8.6 s, and the formation time of nanobubble from the collision of ionic vacancies is 0.072 s.

Original languageEnglish
Pages (from-to)289-298
Number of pages10
JournalMagnetohydrodynamics
Volume48
Issue number2
Publication statusPublished - 2012

Fingerprint

Cyclotrons
Magnetohydrodynamics
magnetohydrodynamics
Vacancies
cyclotrons
life (durability)
Electrodes
electrodes
Magnetic fields
magnetic fields
Lorentz force
collisions
circumferences
Electrodeposition
electrodeposition
Copper
copper
decay

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Physics and Astronomy(all)

Cite this

Aogaki, R., Motomura, K., Sugiyama, A., Morimoto, R., Mogi, I., Miura, M., ... Oshikiri, Y. (2012). Measurement of the lifetime of ionic vacancy by the cyclotron-MHD electrode. Magnetohydrodynamics, 48(2), 289-298.

Measurement of the lifetime of ionic vacancy by the cyclotron-MHD electrode. / Aogaki, R.; Motomura, K.; Sugiyama, A.; Morimoto, R.; Mogi, I.; Miura, M.; Asanuma, M.; Oshikiri, Y.

In: Magnetohydrodynamics, Vol. 48, No. 2, 2012, p. 289-298.

Research output: Contribution to journalArticle

Aogaki, R, Motomura, K, Sugiyama, A, Morimoto, R, Mogi, I, Miura, M, Asanuma, M & Oshikiri, Y 2012, 'Measurement of the lifetime of ionic vacancy by the cyclotron-MHD electrode', Magnetohydrodynamics, vol. 48, no. 2, pp. 289-298.
Aogaki R, Motomura K, Sugiyama A, Morimoto R, Mogi I, Miura M et al. Measurement of the lifetime of ionic vacancy by the cyclotron-MHD electrode. Magnetohydrodynamics. 2012;48(2):289-298.
Aogaki, R. ; Motomura, K. ; Sugiyama, A. ; Morimoto, R. ; Mogi, I. ; Miura, M. ; Asanuma, M. ; Oshikiri, Y. / Measurement of the lifetime of ionic vacancy by the cyclotron-MHD electrode. In: Magnetohydrodynamics. 2012 ; Vol. 48, No. 2. pp. 289-298.
@article{f70a2f7387d843ec8051b7fdc2be9326,
title = "Measurement of the lifetime of ionic vacancy by the cyclotron-MHD electrode",
abstract = "With a new type of magnetohydrodynamic (MHD) electrode called cyclotron MHD electrode (CMHDE), the lifetime of ionic vacancy created in copper electrodeposition has been first measured. In a CMHDE, coaxial cylinders partly exposed as electrodes are placed vertically in an electrolytic solution under a vertical magnetic field, so that induced Lorentz force makes ionic vacancies circulate together with the solution along the circumferences. At low magnetic fields, ionic vacancies once created become extinct on the way of returning, whereas at high magnetic fields, they can come back to their initial birth points in enhanced velocities. By detecting the difference between these two states, we can measure the lifetime of ionic vacancy. At the same time, by changing the collision efficiency between created and returning vacancies, two reaction processes, i.e., the decay of ionic vacancy and the conversion to nanobubble can be analyzed. As a result, in the present case, it was concluded that the intrinsic lifetime of ionic vacancy is 8.6 s, and the formation time of nanobubble from the collision of ionic vacancies is 0.072 s.",
author = "R. Aogaki and K. Motomura and A. Sugiyama and R. Morimoto and I. Mogi and M. Miura and M. Asanuma and Y. Oshikiri",
year = "2012",
language = "English",
volume = "48",
pages = "289--298",
journal = "Magnetohydrodynamics",
issn = "0024-998X",
publisher = "Institute of Physics, University of Latvia",
number = "2",

}

TY - JOUR

T1 - Measurement of the lifetime of ionic vacancy by the cyclotron-MHD electrode

AU - Aogaki, R.

AU - Motomura, K.

AU - Sugiyama, A.

AU - Morimoto, R.

AU - Mogi, I.

AU - Miura, M.

AU - Asanuma, M.

AU - Oshikiri, Y.

PY - 2012

Y1 - 2012

N2 - With a new type of magnetohydrodynamic (MHD) electrode called cyclotron MHD electrode (CMHDE), the lifetime of ionic vacancy created in copper electrodeposition has been first measured. In a CMHDE, coaxial cylinders partly exposed as electrodes are placed vertically in an electrolytic solution under a vertical magnetic field, so that induced Lorentz force makes ionic vacancies circulate together with the solution along the circumferences. At low magnetic fields, ionic vacancies once created become extinct on the way of returning, whereas at high magnetic fields, they can come back to their initial birth points in enhanced velocities. By detecting the difference between these two states, we can measure the lifetime of ionic vacancy. At the same time, by changing the collision efficiency between created and returning vacancies, two reaction processes, i.e., the decay of ionic vacancy and the conversion to nanobubble can be analyzed. As a result, in the present case, it was concluded that the intrinsic lifetime of ionic vacancy is 8.6 s, and the formation time of nanobubble from the collision of ionic vacancies is 0.072 s.

AB - With a new type of magnetohydrodynamic (MHD) electrode called cyclotron MHD electrode (CMHDE), the lifetime of ionic vacancy created in copper electrodeposition has been first measured. In a CMHDE, coaxial cylinders partly exposed as electrodes are placed vertically in an electrolytic solution under a vertical magnetic field, so that induced Lorentz force makes ionic vacancies circulate together with the solution along the circumferences. At low magnetic fields, ionic vacancies once created become extinct on the way of returning, whereas at high magnetic fields, they can come back to their initial birth points in enhanced velocities. By detecting the difference between these two states, we can measure the lifetime of ionic vacancy. At the same time, by changing the collision efficiency between created and returning vacancies, two reaction processes, i.e., the decay of ionic vacancy and the conversion to nanobubble can be analyzed. As a result, in the present case, it was concluded that the intrinsic lifetime of ionic vacancy is 8.6 s, and the formation time of nanobubble from the collision of ionic vacancies is 0.072 s.

UR - http://www.scopus.com/inward/record.url?scp=84870229684&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84870229684&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84870229684

VL - 48

SP - 289

EP - 298

JO - Magnetohydrodynamics

JF - Magnetohydrodynamics

SN - 0024-998X

IS - 2

ER -