Mechanical properties and structural analyses of new types of footing used in breakwater caissons.

H. Yokota, O. Kiyomiya

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Loading tests were carried out on quarter scale breakwater caissons with buttress and box footings. Bond splitting failure occurred along the reinforcing bars in the buttress and plane shear failure in the box footing. Results from finite element design methods were shown to be satisfactory for structural safety.

Original languageEnglish
Title of host publicationREPORT OF THE PORT & HARBOUR RES. INST.
Pages577-618
Number of pages42
Volume26
Edition2 , Jun. 1987
Publication statusPublished - 1987
Externally publishedYes

Fingerprint

Caissons
Breakwaters
Mechanical properties

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Yokota, H., & Kiyomiya, O. (1987). Mechanical properties and structural analyses of new types of footing used in breakwater caissons. In REPORT OF THE PORT & HARBOUR RES. INST. (2 , Jun. 1987 ed., Vol. 26, pp. 577-618)

Mechanical properties and structural analyses of new types of footing used in breakwater caissons. / Yokota, H.; Kiyomiya, O.

REPORT OF THE PORT & HARBOUR RES. INST.. Vol. 26 2 , Jun. 1987. ed. 1987. p. 577-618.

Research output: Chapter in Book/Report/Conference proceedingChapter

Yokota, H & Kiyomiya, O 1987, Mechanical properties and structural analyses of new types of footing used in breakwater caissons. in REPORT OF THE PORT & HARBOUR RES. INST.. 2 , Jun. 1987 edn, vol. 26, pp. 577-618.
Yokota H, Kiyomiya O. Mechanical properties and structural analyses of new types of footing used in breakwater caissons. In REPORT OF THE PORT & HARBOUR RES. INST.. 2 , Jun. 1987 ed. Vol. 26. 1987. p. 577-618
Yokota, H. ; Kiyomiya, O. / Mechanical properties and structural analyses of new types of footing used in breakwater caissons. REPORT OF THE PORT & HARBOUR RES. INST.. Vol. 26 2 , Jun. 1987. ed. 1987. pp. 577-618
@inbook{f9a829f7d6a5458e8365cd5acd82b5a9,
title = "Mechanical properties and structural analyses of new types of footing used in breakwater caissons.",
abstract = "Loading tests were carried out on quarter scale breakwater caissons with buttress and box footings. Bond splitting failure occurred along the reinforcing bars in the buttress and plane shear failure in the box footing. Results from finite element design methods were shown to be satisfactory for structural safety.",
author = "H. Yokota and O. Kiyomiya",
year = "1987",
language = "English",
volume = "26",
pages = "577--618",
booktitle = "REPORT OF THE PORT & HARBOUR RES. INST.",
edition = "2 , Jun. 1987",

}

TY - CHAP

T1 - Mechanical properties and structural analyses of new types of footing used in breakwater caissons.

AU - Yokota, H.

AU - Kiyomiya, O.

PY - 1987

Y1 - 1987

N2 - Loading tests were carried out on quarter scale breakwater caissons with buttress and box footings. Bond splitting failure occurred along the reinforcing bars in the buttress and plane shear failure in the box footing. Results from finite element design methods were shown to be satisfactory for structural safety.

AB - Loading tests were carried out on quarter scale breakwater caissons with buttress and box footings. Bond splitting failure occurred along the reinforcing bars in the buttress and plane shear failure in the box footing. Results from finite element design methods were shown to be satisfactory for structural safety.

UR - http://www.scopus.com/inward/record.url?scp=0023102172&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023102172&partnerID=8YFLogxK

M3 - Chapter

VL - 26

SP - 577

EP - 618

BT - REPORT OF THE PORT & HARBOUR RES. INST.

ER -