New two-dimensional position sensitive silicon detector with good position linearity and resolution

T. Yanagimachi, T. Doke, Nobuyuki Hasebe, T. Imai, T. Kashiwagi, J. Kikuchi, T. Kohno, W. P. Liu, K. Munakata, T. Motobayashi, H. Murakami, K. Nagata, A. Nakamoto, H. Yamaguchi

Research output: Contribution to journalArticle

48 Citations (Scopus)

Abstract

A two-dimensional position sensitive silicon detector (PSSD) with a good linear response, consisting of a square ion-implanted resistive anode with a boundary of an additional resistive-strip electrode, was newly developed. Linearity and resolution for the PSSD were investigated using 40 MeV helium and 95 MeV nitrogen ion beams. The PSSD has an effective area of 45 mm×45 mm, a thickness of 400 μm, a junction capacitance of 500 pF, a surface resistance of the ion-implanted resistive anode of 18 kω□ and a resistance of the strip line of 1.4 kω. The nonlinearities and resolutions (FWHM) of the position were 0.75% and 1.97 mm for 40 MeV helium ions obtained by 6 μs pulse shaping, and 0.47% and 0.71 mm for 95 MeV nitrogen ions obtained by 12 μs pulse shaping, respectively.

Original languageEnglish
Pages (from-to)307-314
Number of pages8
JournalNuclear Inst. and Methods in Physics Research, A
Volume275
Issue number2
DOIs
Publication statusPublished - 1989 Feb 15
Externally publishedYes

Fingerprint

Silicon detectors
linearity
Pulse shaping
nitrogen ions
detectors
Ions
silicon
Helium
strip
Anodes
anodes
Nitrogen
Strip telecommunication lines
Surface resistance
helium ions
Full width at half maximum
pulses
Ion beams
ions
Capacitance

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics
  • Engineering(all)

Cite this

New two-dimensional position sensitive silicon detector with good position linearity and resolution. / Yanagimachi, T.; Doke, T.; Hasebe, Nobuyuki; Imai, T.; Kashiwagi, T.; Kikuchi, J.; Kohno, T.; Liu, W. P.; Munakata, K.; Motobayashi, T.; Murakami, H.; Nagata, K.; Nakamoto, A.; Yamaguchi, H.

In: Nuclear Inst. and Methods in Physics Research, A, Vol. 275, No. 2, 15.02.1989, p. 307-314.

Research output: Contribution to journalArticle

Yanagimachi, T, Doke, T, Hasebe, N, Imai, T, Kashiwagi, T, Kikuchi, J, Kohno, T, Liu, WP, Munakata, K, Motobayashi, T, Murakami, H, Nagata, K, Nakamoto, A & Yamaguchi, H 1989, 'New two-dimensional position sensitive silicon detector with good position linearity and resolution', Nuclear Inst. and Methods in Physics Research, A, vol. 275, no. 2, pp. 307-314. https://doi.org/10.1016/0168-9002(89)90702-X
Yanagimachi, T. ; Doke, T. ; Hasebe, Nobuyuki ; Imai, T. ; Kashiwagi, T. ; Kikuchi, J. ; Kohno, T. ; Liu, W. P. ; Munakata, K. ; Motobayashi, T. ; Murakami, H. ; Nagata, K. ; Nakamoto, A. ; Yamaguchi, H. / New two-dimensional position sensitive silicon detector with good position linearity and resolution. In: Nuclear Inst. and Methods in Physics Research, A. 1989 ; Vol. 275, No. 2. pp. 307-314.
@article{d334cb4d83834fde929dc4ff4722afca,
title = "New two-dimensional position sensitive silicon detector with good position linearity and resolution",
abstract = "A two-dimensional position sensitive silicon detector (PSSD) with a good linear response, consisting of a square ion-implanted resistive anode with a boundary of an additional resistive-strip electrode, was newly developed. Linearity and resolution for the PSSD were investigated using 40 MeV helium and 95 MeV nitrogen ion beams. The PSSD has an effective area of 45 mm×45 mm, a thickness of 400 μm, a junction capacitance of 500 pF, a surface resistance of the ion-implanted resistive anode of 18 kω□ and a resistance of the strip line of 1.4 kω. The nonlinearities and resolutions (FWHM) of the position were 0.75{\%} and 1.97 mm for 40 MeV helium ions obtained by 6 μs pulse shaping, and 0.47{\%} and 0.71 mm for 95 MeV nitrogen ions obtained by 12 μs pulse shaping, respectively.",
author = "T. Yanagimachi and T. Doke and Nobuyuki Hasebe and T. Imai and T. Kashiwagi and J. Kikuchi and T. Kohno and Liu, {W. P.} and K. Munakata and T. Motobayashi and H. Murakami and K. Nagata and A. Nakamoto and H. Yamaguchi",
year = "1989",
month = "2",
day = "15",
doi = "10.1016/0168-9002(89)90702-X",
language = "English",
volume = "275",
pages = "307--314",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - New two-dimensional position sensitive silicon detector with good position linearity and resolution

AU - Yanagimachi, T.

AU - Doke, T.

AU - Hasebe, Nobuyuki

AU - Imai, T.

AU - Kashiwagi, T.

AU - Kikuchi, J.

AU - Kohno, T.

AU - Liu, W. P.

AU - Munakata, K.

AU - Motobayashi, T.

AU - Murakami, H.

AU - Nagata, K.

AU - Nakamoto, A.

AU - Yamaguchi, H.

PY - 1989/2/15

Y1 - 1989/2/15

N2 - A two-dimensional position sensitive silicon detector (PSSD) with a good linear response, consisting of a square ion-implanted resistive anode with a boundary of an additional resistive-strip electrode, was newly developed. Linearity and resolution for the PSSD were investigated using 40 MeV helium and 95 MeV nitrogen ion beams. The PSSD has an effective area of 45 mm×45 mm, a thickness of 400 μm, a junction capacitance of 500 pF, a surface resistance of the ion-implanted resistive anode of 18 kω□ and a resistance of the strip line of 1.4 kω. The nonlinearities and resolutions (FWHM) of the position were 0.75% and 1.97 mm for 40 MeV helium ions obtained by 6 μs pulse shaping, and 0.47% and 0.71 mm for 95 MeV nitrogen ions obtained by 12 μs pulse shaping, respectively.

AB - A two-dimensional position sensitive silicon detector (PSSD) with a good linear response, consisting of a square ion-implanted resistive anode with a boundary of an additional resistive-strip electrode, was newly developed. Linearity and resolution for the PSSD were investigated using 40 MeV helium and 95 MeV nitrogen ion beams. The PSSD has an effective area of 45 mm×45 mm, a thickness of 400 μm, a junction capacitance of 500 pF, a surface resistance of the ion-implanted resistive anode of 18 kω□ and a resistance of the strip line of 1.4 kω. The nonlinearities and resolutions (FWHM) of the position were 0.75% and 1.97 mm for 40 MeV helium ions obtained by 6 μs pulse shaping, and 0.47% and 0.71 mm for 95 MeV nitrogen ions obtained by 12 μs pulse shaping, respectively.

UR - http://www.scopus.com/inward/record.url?scp=0024606585&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024606585&partnerID=8YFLogxK

U2 - 10.1016/0168-9002(89)90702-X

DO - 10.1016/0168-9002(89)90702-X

M3 - Article

AN - SCOPUS:0024606585

VL - 275

SP - 307

EP - 314

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 2

ER -