Optical detection/collection of toxic Cd(II) ions using cubic Ia3d aluminosilica mesocage sensors

Sherif A. El-Safty, Mohamed A. Shenashen, Mohamed Khairy

    Research output: Contribution to journalArticle

    34 Citations (Scopus)

    Abstract

    Optical sensors for selective removal and detection of extremely toxic ions such as cadmium (CdII) in aquatic samples were successfully fabricated via simple strategy. Aluminosilica-based network platforms are used as selective mesopore shape and size carriers in order to fabricate optical sensors through the direct functionalization of α, β, γ, and δ-tetrakis(1-methylpyridinium-4-yl)porphine ρ-toluenesulfonate (TMPyP) moieties without any prior surface modification using silane or thiol agents. In turn, the key advantage of a heretical three-dimensional (3D) cubic Ia3d mesocage is the facile access of target ions such as ion transports and the high affinity responses of TMPyP receptor-Cd(II) analyte binding events, which result in the easy generation and transduction of optical signals even at the trace level of the Cd(II) ion. The optical sensor design-based aluminosilica cages enable the sensitive detection and selective removal of Cd(II) ions even at ultra-trace concentrations of 10-10 mol/dm3 with rapid response time (in minutes). This rational strategy is crucial to the development of optical mesocollectors (i.e., probe surface-mounted naked-eye ion-sensor strips) with highly selective Cd(II) ion removal from aqueous water. These new classes of optical mesocollectors exhibit long-term stability and reusability of deleterious Cd(II) ions, which makes them efficient for various analytical applications.

    Original languageEnglish
    Pages (from-to)69-78
    Number of pages10
    JournalTalanta
    Volume98
    DOIs
    Publication statusPublished - 2012 Aug 30

    Fingerprint

    Poisons
    Ions
    Sensors
    Optical sensors
    Silanes
    Ion Transport
    Cadmium
    Sulfhydryl Compounds
    Reusability
    Reaction Time
    Signal Transduction
    Surface treatment
    Water

    Keywords

    • Cadmium
    • Cubic Ia3d
    • Detection
    • Optical
    • Removal
    • Sensors

    ASJC Scopus subject areas

    • Chemistry(all)

    Cite this

    Optical detection/collection of toxic Cd(II) ions using cubic Ia3d aluminosilica mesocage sensors. / El-Safty, Sherif A.; Shenashen, Mohamed A.; Khairy, Mohamed.

    In: Talanta, Vol. 98, 30.08.2012, p. 69-78.

    Research output: Contribution to journalArticle

    El-Safty, Sherif A. ; Shenashen, Mohamed A. ; Khairy, Mohamed. / Optical detection/collection of toxic Cd(II) ions using cubic Ia3d aluminosilica mesocage sensors. In: Talanta. 2012 ; Vol. 98. pp. 69-78.
    @article{8222a91a739c445d944c3eec0a4d2913,
    title = "Optical detection/collection of toxic Cd(II) ions using cubic Ia3d aluminosilica mesocage sensors",
    abstract = "Optical sensors for selective removal and detection of extremely toxic ions such as cadmium (CdII) in aquatic samples were successfully fabricated via simple strategy. Aluminosilica-based network platforms are used as selective mesopore shape and size carriers in order to fabricate optical sensors through the direct functionalization of α, β, γ, and δ-tetrakis(1-methylpyridinium-4-yl)porphine ρ-toluenesulfonate (TMPyP) moieties without any prior surface modification using silane or thiol agents. In turn, the key advantage of a heretical three-dimensional (3D) cubic Ia3d mesocage is the facile access of target ions such as ion transports and the high affinity responses of TMPyP receptor-Cd(II) analyte binding events, which result in the easy generation and transduction of optical signals even at the trace level of the Cd(II) ion. The optical sensor design-based aluminosilica cages enable the sensitive detection and selective removal of Cd(II) ions even at ultra-trace concentrations of 10-10 mol/dm3 with rapid response time (in minutes). This rational strategy is crucial to the development of optical mesocollectors (i.e., probe surface-mounted naked-eye ion-sensor strips) with highly selective Cd(II) ion removal from aqueous water. These new classes of optical mesocollectors exhibit long-term stability and reusability of deleterious Cd(II) ions, which makes them efficient for various analytical applications.",
    keywords = "Cadmium, Cubic Ia3d, Detection, Optical, Removal, Sensors",
    author = "El-Safty, {Sherif A.} and Shenashen, {Mohamed A.} and Mohamed Khairy",
    year = "2012",
    month = "8",
    day = "30",
    doi = "10.1016/j.talanta.2012.06.046",
    language = "English",
    volume = "98",
    pages = "69--78",
    journal = "Talanta",
    issn = "0039-9140",
    publisher = "Elsevier",

    }

    TY - JOUR

    T1 - Optical detection/collection of toxic Cd(II) ions using cubic Ia3d aluminosilica mesocage sensors

    AU - El-Safty, Sherif A.

    AU - Shenashen, Mohamed A.

    AU - Khairy, Mohamed

    PY - 2012/8/30

    Y1 - 2012/8/30

    N2 - Optical sensors for selective removal and detection of extremely toxic ions such as cadmium (CdII) in aquatic samples were successfully fabricated via simple strategy. Aluminosilica-based network platforms are used as selective mesopore shape and size carriers in order to fabricate optical sensors through the direct functionalization of α, β, γ, and δ-tetrakis(1-methylpyridinium-4-yl)porphine ρ-toluenesulfonate (TMPyP) moieties without any prior surface modification using silane or thiol agents. In turn, the key advantage of a heretical three-dimensional (3D) cubic Ia3d mesocage is the facile access of target ions such as ion transports and the high affinity responses of TMPyP receptor-Cd(II) analyte binding events, which result in the easy generation and transduction of optical signals even at the trace level of the Cd(II) ion. The optical sensor design-based aluminosilica cages enable the sensitive detection and selective removal of Cd(II) ions even at ultra-trace concentrations of 10-10 mol/dm3 with rapid response time (in minutes). This rational strategy is crucial to the development of optical mesocollectors (i.e., probe surface-mounted naked-eye ion-sensor strips) with highly selective Cd(II) ion removal from aqueous water. These new classes of optical mesocollectors exhibit long-term stability and reusability of deleterious Cd(II) ions, which makes them efficient for various analytical applications.

    AB - Optical sensors for selective removal and detection of extremely toxic ions such as cadmium (CdII) in aquatic samples were successfully fabricated via simple strategy. Aluminosilica-based network platforms are used as selective mesopore shape and size carriers in order to fabricate optical sensors through the direct functionalization of α, β, γ, and δ-tetrakis(1-methylpyridinium-4-yl)porphine ρ-toluenesulfonate (TMPyP) moieties without any prior surface modification using silane or thiol agents. In turn, the key advantage of a heretical three-dimensional (3D) cubic Ia3d mesocage is the facile access of target ions such as ion transports and the high affinity responses of TMPyP receptor-Cd(II) analyte binding events, which result in the easy generation and transduction of optical signals even at the trace level of the Cd(II) ion. The optical sensor design-based aluminosilica cages enable the sensitive detection and selective removal of Cd(II) ions even at ultra-trace concentrations of 10-10 mol/dm3 with rapid response time (in minutes). This rational strategy is crucial to the development of optical mesocollectors (i.e., probe surface-mounted naked-eye ion-sensor strips) with highly selective Cd(II) ion removal from aqueous water. These new classes of optical mesocollectors exhibit long-term stability and reusability of deleterious Cd(II) ions, which makes them efficient for various analytical applications.

    KW - Cadmium

    KW - Cubic Ia3d

    KW - Detection

    KW - Optical

    KW - Removal

    KW - Sensors

    UR - http://www.scopus.com/inward/record.url?scp=84865694292&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84865694292&partnerID=8YFLogxK

    U2 - 10.1016/j.talanta.2012.06.046

    DO - 10.1016/j.talanta.2012.06.046

    M3 - Article

    C2 - 22939130

    AN - SCOPUS:84865694292

    VL - 98

    SP - 69

    EP - 78

    JO - Talanta

    JF - Talanta

    SN - 0039-9140

    ER -