Abstract

High performance flow monitoring systems are needed to monitor the particles and biomolecules flow in micro channels. For the design of microfluidic devices and systems, the finite element analysis tools play an important role. These systems are useful to evaluate the correspondence between the computational fluid dynamics (CFD) simulation and the actual flow in micro channels. The micro flow cell realizing 3D sheath flow was designed and the prototype was fabricated and evaluated. Since the flow distribution of the sample is critically changed with the pressure and the flow rate of the carrier, the 3D CFD analysis is indispensable to design the micro flow cell. The principle of 3D sheath flow is applicable to realize particles and biomolecules observation and handling systems. Novel micro flow switches using thermal gelation of methylcellulose (MC) have been developed. Since the local plug is formed illuminating the laser beam, the flow can be stopped at any point in the microchannels. The switching time of about 1 sec both open-to-close and close-to-open was achieved. By using the MC as a carrier flow, DNA, protein and biological cell sorting micro flow systems can be realized in the simple 2D microchannel structures.

Original languageEnglish
Title of host publicationLab-on-a-Chip: Miniaturized Systems for (Bio) Chemical Analysis and Synthesis
PublisherElsevier Inc.
Pages205-214
Number of pages10
ISBN (Print)9780444511003
DOIs
Publication statusPublished - 2003 Oct

Fingerprint

Methylcellulose
Biomolecules
Microchannels
Computational fluid dynamics
Lab-On-A-Chip Devices
Hydrodynamics
Molecules
Gelation
Sorting
Microfluidics
Dynamic analysis
Laser beams
Finite Element Analysis
Cells
Switches
Flow rate
Finite element method
Monitoring
DNA
Computer simulation

ASJC Scopus subject areas

  • Biochemistry, Genetics and Molecular Biology(all)

Cite this

Shoji, S., Tashiro, K., Sekiguchi, T., Sato, H., Honda, N., & Funatu, T. (2003). Particles and molecules handling in micro channels. In Lab-on-a-Chip: Miniaturized Systems for (Bio) Chemical Analysis and Synthesis (pp. 205-214). Elsevier Inc.. https://doi.org/10.1016/B978-044451100-3/50010-3

Particles and molecules handling in micro channels. / Shoji, Shuichi; Tashiro, K.; Sekiguchi, Tetsushi; Sato, H.; Honda, N.; Funatu, T.

Lab-on-a-Chip: Miniaturized Systems for (Bio) Chemical Analysis and Synthesis. Elsevier Inc., 2003. p. 205-214.

Research output: Chapter in Book/Report/Conference proceedingChapter

Shoji, S, Tashiro, K, Sekiguchi, T, Sato, H, Honda, N & Funatu, T 2003, Particles and molecules handling in micro channels. in Lab-on-a-Chip: Miniaturized Systems for (Bio) Chemical Analysis and Synthesis. Elsevier Inc., pp. 205-214. https://doi.org/10.1016/B978-044451100-3/50010-3
Shoji S, Tashiro K, Sekiguchi T, Sato H, Honda N, Funatu T. Particles and molecules handling in micro channels. In Lab-on-a-Chip: Miniaturized Systems for (Bio) Chemical Analysis and Synthesis. Elsevier Inc. 2003. p. 205-214 https://doi.org/10.1016/B978-044451100-3/50010-3
Shoji, Shuichi ; Tashiro, K. ; Sekiguchi, Tetsushi ; Sato, H. ; Honda, N. ; Funatu, T. / Particles and molecules handling in micro channels. Lab-on-a-Chip: Miniaturized Systems for (Bio) Chemical Analysis and Synthesis. Elsevier Inc., 2003. pp. 205-214
@inbook{28840968f8294d89aedd0600bfdb8811,
title = "Particles and molecules handling in micro channels",
abstract = "High performance flow monitoring systems are needed to monitor the particles and biomolecules flow in micro channels. For the design of microfluidic devices and systems, the finite element analysis tools play an important role. These systems are useful to evaluate the correspondence between the computational fluid dynamics (CFD) simulation and the actual flow in micro channels. The micro flow cell realizing 3D sheath flow was designed and the prototype was fabricated and evaluated. Since the flow distribution of the sample is critically changed with the pressure and the flow rate of the carrier, the 3D CFD analysis is indispensable to design the micro flow cell. The principle of 3D sheath flow is applicable to realize particles and biomolecules observation and handling systems. Novel micro flow switches using thermal gelation of methylcellulose (MC) have been developed. Since the local plug is formed illuminating the laser beam, the flow can be stopped at any point in the microchannels. The switching time of about 1 sec both open-to-close and close-to-open was achieved. By using the MC as a carrier flow, DNA, protein and biological cell sorting micro flow systems can be realized in the simple 2D microchannel structures.",
author = "Shuichi Shoji and K. Tashiro and Tetsushi Sekiguchi and H. Sato and N. Honda and T. Funatu",
year = "2003",
month = "10",
doi = "10.1016/B978-044451100-3/50010-3",
language = "English",
isbn = "9780444511003",
pages = "205--214",
booktitle = "Lab-on-a-Chip: Miniaturized Systems for (Bio) Chemical Analysis and Synthesis",
publisher = "Elsevier Inc.",

}

TY - CHAP

T1 - Particles and molecules handling in micro channels

AU - Shoji, Shuichi

AU - Tashiro, K.

AU - Sekiguchi, Tetsushi

AU - Sato, H.

AU - Honda, N.

AU - Funatu, T.

PY - 2003/10

Y1 - 2003/10

N2 - High performance flow monitoring systems are needed to monitor the particles and biomolecules flow in micro channels. For the design of microfluidic devices and systems, the finite element analysis tools play an important role. These systems are useful to evaluate the correspondence between the computational fluid dynamics (CFD) simulation and the actual flow in micro channels. The micro flow cell realizing 3D sheath flow was designed and the prototype was fabricated and evaluated. Since the flow distribution of the sample is critically changed with the pressure and the flow rate of the carrier, the 3D CFD analysis is indispensable to design the micro flow cell. The principle of 3D sheath flow is applicable to realize particles and biomolecules observation and handling systems. Novel micro flow switches using thermal gelation of methylcellulose (MC) have been developed. Since the local plug is formed illuminating the laser beam, the flow can be stopped at any point in the microchannels. The switching time of about 1 sec both open-to-close and close-to-open was achieved. By using the MC as a carrier flow, DNA, protein and biological cell sorting micro flow systems can be realized in the simple 2D microchannel structures.

AB - High performance flow monitoring systems are needed to monitor the particles and biomolecules flow in micro channels. For the design of microfluidic devices and systems, the finite element analysis tools play an important role. These systems are useful to evaluate the correspondence between the computational fluid dynamics (CFD) simulation and the actual flow in micro channels. The micro flow cell realizing 3D sheath flow was designed and the prototype was fabricated and evaluated. Since the flow distribution of the sample is critically changed with the pressure and the flow rate of the carrier, the 3D CFD analysis is indispensable to design the micro flow cell. The principle of 3D sheath flow is applicable to realize particles and biomolecules observation and handling systems. Novel micro flow switches using thermal gelation of methylcellulose (MC) have been developed. Since the local plug is formed illuminating the laser beam, the flow can be stopped at any point in the microchannels. The switching time of about 1 sec both open-to-close and close-to-open was achieved. By using the MC as a carrier flow, DNA, protein and biological cell sorting micro flow systems can be realized in the simple 2D microchannel structures.

UR - http://www.scopus.com/inward/record.url?scp=47349106740&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=47349106740&partnerID=8YFLogxK

U2 - 10.1016/B978-044451100-3/50010-3

DO - 10.1016/B978-044451100-3/50010-3

M3 - Chapter

SN - 9780444511003

SP - 205

EP - 214

BT - Lab-on-a-Chip: Miniaturized Systems for (Bio) Chemical Analysis and Synthesis

PB - Elsevier Inc.

ER -