Polymer waveguide-type Kretschmann-structure surface plasmon sensor at 1550nm wavelength range

Naoya Hidaka, Yasuaki Kuroda, Yuichi Matsushima, Katsuyuki Utaka

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    1 Citation (Scopus)

    Abstract

    Polymer waveguide-type Kretschmann-structure surface plasmon resonance (SPR) sensor was studied for compact, low-cost remote sensing application operated at 1550nm wavelength range. In order to confirm the fundamental operation, a concentration of 2-propanol in water was changed to attain 136/RIU.

    Original languageEnglish
    Title of host publicationTechnical Digest of the 18th Microoptics Conference, MOC 2013
    Publication statusPublished - 2013
    Event2013 18th Microoptics Conference, MOC 2013 - Tokyo
    Duration: 2013 Oct 272013 Oct 30

    Other

    Other2013 18th Microoptics Conference, MOC 2013
    CityTokyo
    Period13/10/2713/10/30

    Fingerprint

    2-Propanol
    Surface plasmon resonance
    Propanol
    Surface structure
    Remote sensing
    Polymers
    Waveguides
    Wavelength
    Water
    Sensors
    Costs

    ASJC Scopus subject areas

    • Electronic, Optical and Magnetic Materials

    Cite this

    Hidaka, N., Kuroda, Y., Matsushima, Y., & Utaka, K. (2013). Polymer waveguide-type Kretschmann-structure surface plasmon sensor at 1550nm wavelength range. In Technical Digest of the 18th Microoptics Conference, MOC 2013 [6715136]

    Polymer waveguide-type Kretschmann-structure surface plasmon sensor at 1550nm wavelength range. / Hidaka, Naoya; Kuroda, Yasuaki; Matsushima, Yuichi; Utaka, Katsuyuki.

    Technical Digest of the 18th Microoptics Conference, MOC 2013. 2013. 6715136.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Hidaka, N, Kuroda, Y, Matsushima, Y & Utaka, K 2013, Polymer waveguide-type Kretschmann-structure surface plasmon sensor at 1550nm wavelength range. in Technical Digest of the 18th Microoptics Conference, MOC 2013., 6715136, 2013 18th Microoptics Conference, MOC 2013, Tokyo, 13/10/27.
    Hidaka N, Kuroda Y, Matsushima Y, Utaka K. Polymer waveguide-type Kretschmann-structure surface plasmon sensor at 1550nm wavelength range. In Technical Digest of the 18th Microoptics Conference, MOC 2013. 2013. 6715136
    Hidaka, Naoya ; Kuroda, Yasuaki ; Matsushima, Yuichi ; Utaka, Katsuyuki. / Polymer waveguide-type Kretschmann-structure surface plasmon sensor at 1550nm wavelength range. Technical Digest of the 18th Microoptics Conference, MOC 2013. 2013.
    @inproceedings{4807b8321b1c4443986307e2d81219ed,
    title = "Polymer waveguide-type Kretschmann-structure surface plasmon sensor at 1550nm wavelength range",
    abstract = "Polymer waveguide-type Kretschmann-structure surface plasmon resonance (SPR) sensor was studied for compact, low-cost remote sensing application operated at 1550nm wavelength range. In order to confirm the fundamental operation, a concentration of 2-propanol in water was changed to attain 136/RIU.",
    author = "Naoya Hidaka and Yasuaki Kuroda and Yuichi Matsushima and Katsuyuki Utaka",
    year = "2013",
    language = "English",
    isbn = "9784863483453",
    booktitle = "Technical Digest of the 18th Microoptics Conference, MOC 2013",

    }

    TY - GEN

    T1 - Polymer waveguide-type Kretschmann-structure surface plasmon sensor at 1550nm wavelength range

    AU - Hidaka, Naoya

    AU - Kuroda, Yasuaki

    AU - Matsushima, Yuichi

    AU - Utaka, Katsuyuki

    PY - 2013

    Y1 - 2013

    N2 - Polymer waveguide-type Kretschmann-structure surface plasmon resonance (SPR) sensor was studied for compact, low-cost remote sensing application operated at 1550nm wavelength range. In order to confirm the fundamental operation, a concentration of 2-propanol in water was changed to attain 136/RIU.

    AB - Polymer waveguide-type Kretschmann-structure surface plasmon resonance (SPR) sensor was studied for compact, low-cost remote sensing application operated at 1550nm wavelength range. In order to confirm the fundamental operation, a concentration of 2-propanol in water was changed to attain 136/RIU.

    UR - http://www.scopus.com/inward/record.url?scp=84894109324&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84894109324&partnerID=8YFLogxK

    M3 - Conference contribution

    AN - SCOPUS:84894109324

    SN - 9784863483453

    BT - Technical Digest of the 18th Microoptics Conference, MOC 2013

    ER -