Power system quality improvement using doubly-fed rotary frequency converter

Masanobu Kajihara, Kota Ezaki, Masafumi Okuda, Goro Fujita, Ryuichi Yokoyama, Kaoru Koyanagi, Toshihisa Funabashi

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Abstract

    An application of rotary frequency converter for a wind farm system is proposed in this paper. Wind power is getting attention for prospective renewal energy sources, and introduction of wind farm generation will solve environmental matters and energy exhaust problem. However, the quality of power system frequency will be degraded as the capacity of wind power generator increases. Attenuation of mismatch between the served power and load demand is most important problem in order to increase number of wind generators. A wind firm is connected to the proposed rotary frequency converter as a buffer to connect the wind farm and the power system. This provides energy storage function of the output power associated with irregular wind power. The converter has a synchronous generator and a doubly-fed machine. The synchronous motor is connected to the wind farm to supply AC voltage for induction generators of wind power generation units. The shaft of the doubly-fed machine is mechanically jointed to the synchronous motor, and rotates together. Tuning the current of the secondary winding supplied by cycloconverter or self-commutated inverter controls the output power. At present, doubly-fed machine is commonly used in pumped storage hydraulic power plants recently constructed. The proposed scheme is an expansion from the present application. In order to evaluate the proposed scheme, firstly, load reference simulation test is carried out for discussion of the power exchange response to a power grid. Secondly, experimental study is discussed in order to identify the required capacity for the rotary frequency converter to improve the frequency quality. These studies show preferable characteristic for the viewpoint of power system quality improvement.

    Original languageEnglish
    Title of host publicationProceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout
    EditorsA. Domijan, Jr.
    Pages200-204
    Number of pages5
    Publication statusPublished - 2003
    EventProceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout - New York, NY.
    Duration: 2003 Dec 102003 Dec 12

    Other

    OtherProceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout
    CityNew York, NY.
    Period03/12/1003/12/12

    Fingerprint

    Frequency converters
    Farms
    Wind power
    Synchronous motors
    Asynchronous generators
    Synchronous generators
    Energy storage
    Power generation
    Power plants
    Tuning
    Hydraulics
    Electric potential

    Keywords

    • Flywheel
    • Rotary frequency converter
    • Wind generation

    ASJC Scopus subject areas

    • Engineering(all)

    Cite this

    Kajihara, M., Ezaki, K., Okuda, M., Fujita, G., Yokoyama, R., Koyanagi, K., & Funabashi, T. (2003). Power system quality improvement using doubly-fed rotary frequency converter. In A. Domijan, Jr. (Ed.), Proceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout (pp. 200-204)

    Power system quality improvement using doubly-fed rotary frequency converter. / Kajihara, Masanobu; Ezaki, Kota; Okuda, Masafumi; Fujita, Goro; Yokoyama, Ryuichi; Koyanagi, Kaoru; Funabashi, Toshihisa.

    Proceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout. ed. / A. Domijan, Jr. 2003. p. 200-204.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Kajihara, M, Ezaki, K, Okuda, M, Fujita, G, Yokoyama, R, Koyanagi, K & Funabashi, T 2003, Power system quality improvement using doubly-fed rotary frequency converter. in A Domijan, Jr. (ed.), Proceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout. pp. 200-204, Proceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout, New York, NY., 03/12/10.
    Kajihara M, Ezaki K, Okuda M, Fujita G, Yokoyama R, Koyanagi K et al. Power system quality improvement using doubly-fed rotary frequency converter. In Domijan, Jr. A, editor, Proceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout. 2003. p. 200-204
    Kajihara, Masanobu ; Ezaki, Kota ; Okuda, Masafumi ; Fujita, Goro ; Yokoyama, Ryuichi ; Koyanagi, Kaoru ; Funabashi, Toshihisa. / Power system quality improvement using doubly-fed rotary frequency converter. Proceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout. editor / A. Domijan, Jr. 2003. pp. 200-204
    @inproceedings{7a7244bca420473cb03e9142c888be80,
    title = "Power system quality improvement using doubly-fed rotary frequency converter",
    abstract = "An application of rotary frequency converter for a wind farm system is proposed in this paper. Wind power is getting attention for prospective renewal energy sources, and introduction of wind farm generation will solve environmental matters and energy exhaust problem. However, the quality of power system frequency will be degraded as the capacity of wind power generator increases. Attenuation of mismatch between the served power and load demand is most important problem in order to increase number of wind generators. A wind firm is connected to the proposed rotary frequency converter as a buffer to connect the wind farm and the power system. This provides energy storage function of the output power associated with irregular wind power. The converter has a synchronous generator and a doubly-fed machine. The synchronous motor is connected to the wind farm to supply AC voltage for induction generators of wind power generation units. The shaft of the doubly-fed machine is mechanically jointed to the synchronous motor, and rotates together. Tuning the current of the secondary winding supplied by cycloconverter or self-commutated inverter controls the output power. At present, doubly-fed machine is commonly used in pumped storage hydraulic power plants recently constructed. The proposed scheme is an expansion from the present application. In order to evaluate the proposed scheme, firstly, load reference simulation test is carried out for discussion of the power exchange response to a power grid. Secondly, experimental study is discussed in order to identify the required capacity for the rotary frequency converter to improve the frequency quality. These studies show preferable characteristic for the viewpoint of power system quality improvement.",
    keywords = "Flywheel, Rotary frequency converter, Wind generation",
    author = "Masanobu Kajihara and Kota Ezaki and Masafumi Okuda and Goro Fujita and Ryuichi Yokoyama and Kaoru Koyanagi and Toshihisa Funabashi",
    year = "2003",
    language = "English",
    isbn = "0889864004",
    pages = "200--204",
    editor = "{Domijan, Jr.}, A.",
    booktitle = "Proceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout",

    }

    TY - GEN

    T1 - Power system quality improvement using doubly-fed rotary frequency converter

    AU - Kajihara, Masanobu

    AU - Ezaki, Kota

    AU - Okuda, Masafumi

    AU - Fujita, Goro

    AU - Yokoyama, Ryuichi

    AU - Koyanagi, Kaoru

    AU - Funabashi, Toshihisa

    PY - 2003

    Y1 - 2003

    N2 - An application of rotary frequency converter for a wind farm system is proposed in this paper. Wind power is getting attention for prospective renewal energy sources, and introduction of wind farm generation will solve environmental matters and energy exhaust problem. However, the quality of power system frequency will be degraded as the capacity of wind power generator increases. Attenuation of mismatch between the served power and load demand is most important problem in order to increase number of wind generators. A wind firm is connected to the proposed rotary frequency converter as a buffer to connect the wind farm and the power system. This provides energy storage function of the output power associated with irregular wind power. The converter has a synchronous generator and a doubly-fed machine. The synchronous motor is connected to the wind farm to supply AC voltage for induction generators of wind power generation units. The shaft of the doubly-fed machine is mechanically jointed to the synchronous motor, and rotates together. Tuning the current of the secondary winding supplied by cycloconverter or self-commutated inverter controls the output power. At present, doubly-fed machine is commonly used in pumped storage hydraulic power plants recently constructed. The proposed scheme is an expansion from the present application. In order to evaluate the proposed scheme, firstly, load reference simulation test is carried out for discussion of the power exchange response to a power grid. Secondly, experimental study is discussed in order to identify the required capacity for the rotary frequency converter to improve the frequency quality. These studies show preferable characteristic for the viewpoint of power system quality improvement.

    AB - An application of rotary frequency converter for a wind farm system is proposed in this paper. Wind power is getting attention for prospective renewal energy sources, and introduction of wind farm generation will solve environmental matters and energy exhaust problem. However, the quality of power system frequency will be degraded as the capacity of wind power generator increases. Attenuation of mismatch between the served power and load demand is most important problem in order to increase number of wind generators. A wind firm is connected to the proposed rotary frequency converter as a buffer to connect the wind farm and the power system. This provides energy storage function of the output power associated with irregular wind power. The converter has a synchronous generator and a doubly-fed machine. The synchronous motor is connected to the wind farm to supply AC voltage for induction generators of wind power generation units. The shaft of the doubly-fed machine is mechanically jointed to the synchronous motor, and rotates together. Tuning the current of the secondary winding supplied by cycloconverter or self-commutated inverter controls the output power. At present, doubly-fed machine is commonly used in pumped storage hydraulic power plants recently constructed. The proposed scheme is an expansion from the present application. In order to evaluate the proposed scheme, firstly, load reference simulation test is carried out for discussion of the power exchange response to a power grid. Secondly, experimental study is discussed in order to identify the required capacity for the rotary frequency converter to improve the frequency quality. These studies show preferable characteristic for the viewpoint of power system quality improvement.

    KW - Flywheel

    KW - Rotary frequency converter

    KW - Wind generation

    UR - http://www.scopus.com/inward/record.url?scp=2642554869&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=2642554869&partnerID=8YFLogxK

    M3 - Conference contribution

    AN - SCOPUS:2642554869

    SN - 0889864004

    SP - 200

    EP - 204

    BT - Proceedings of the IASTED International Conference, PowerCon 2003 - Special Theme: Blackout

    A2 - Domijan, Jr., A.

    ER -