Quantitative evaluations of CO 2 reduction by microgrid with PV and battery

Naoki Saito, Takahide Niimura, Kaoru Koyanagi, Ryuichi Yokoyama

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

In this paper, the environmental impact evaluation was examined on an independently operated microgrid. For the evaluation of environmental impact, we measured the amount of CO 2 exhausted from the micro grid when the installation capacity of photovoltaic and of battery was changed. The amount of CO 2 emission was compared by equipment with different amount of the introduction. The capacity of battery installation that achieves the least amount of the CO 2 emission was examined.

Original languageEnglish
Title of host publicationAsia-Pacific Power and Energy Engineering Conference, APPEEC
DOIs
Publication statusPublished - 2009
Event2009 Asia-Pacific Power and Energy Engineering Conference, APPEEC 2009 - Wuhan
Duration: 2009 Mar 272009 Mar 31

Other

Other2009 Asia-Pacific Power and Energy Engineering Conference, APPEEC 2009
CityWuhan
Period09/3/2709/3/31

Fingerprint

Environmental impact

Keywords

  • Battery
  • CO emission
  • Component
  • Environment inpact
  • Microgrid
  • Photovoltaics

ASJC Scopus subject areas

  • Energy Engineering and Power Technology

Cite this

Saito, N., Niimura, T., Koyanagi, K., & Yokoyama, R. (2009). Quantitative evaluations of CO 2 reduction by microgrid with PV and battery. In Asia-Pacific Power and Energy Engineering Conference, APPEEC [4918633] https://doi.org/10.1109/APPEEC.2009.4918633

Quantitative evaluations of CO 2 reduction by microgrid with PV and battery. / Saito, Naoki; Niimura, Takahide; Koyanagi, Kaoru; Yokoyama, Ryuichi.

Asia-Pacific Power and Energy Engineering Conference, APPEEC. 2009. 4918633.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Saito, N, Niimura, T, Koyanagi, K & Yokoyama, R 2009, Quantitative evaluations of CO 2 reduction by microgrid with PV and battery. in Asia-Pacific Power and Energy Engineering Conference, APPEEC., 4918633, 2009 Asia-Pacific Power and Energy Engineering Conference, APPEEC 2009, Wuhan, 09/3/27. https://doi.org/10.1109/APPEEC.2009.4918633
Saito N, Niimura T, Koyanagi K, Yokoyama R. Quantitative evaluations of CO 2 reduction by microgrid with PV and battery. In Asia-Pacific Power and Energy Engineering Conference, APPEEC. 2009. 4918633 https://doi.org/10.1109/APPEEC.2009.4918633
Saito, Naoki ; Niimura, Takahide ; Koyanagi, Kaoru ; Yokoyama, Ryuichi. / Quantitative evaluations of CO 2 reduction by microgrid with PV and battery. Asia-Pacific Power and Energy Engineering Conference, APPEEC. 2009.
@inproceedings{2343121f17754de78592a5f31db0f99d,
title = "Quantitative evaluations of CO 2 reduction by microgrid with PV and battery",
abstract = "In this paper, the environmental impact evaluation was examined on an independently operated microgrid. For the evaluation of environmental impact, we measured the amount of CO 2 exhausted from the micro grid when the installation capacity of photovoltaic and of battery was changed. The amount of CO 2 emission was compared by equipment with different amount of the introduction. The capacity of battery installation that achieves the least amount of the CO 2 emission was examined.",
keywords = "Battery, CO emission, Component, Environment inpact, Microgrid, Photovoltaics",
author = "Naoki Saito and Takahide Niimura and Kaoru Koyanagi and Ryuichi Yokoyama",
year = "2009",
doi = "10.1109/APPEEC.2009.4918633",
language = "English",
isbn = "9781424424870",
booktitle = "Asia-Pacific Power and Energy Engineering Conference, APPEEC",

}

TY - GEN

T1 - Quantitative evaluations of CO 2 reduction by microgrid with PV and battery

AU - Saito, Naoki

AU - Niimura, Takahide

AU - Koyanagi, Kaoru

AU - Yokoyama, Ryuichi

PY - 2009

Y1 - 2009

N2 - In this paper, the environmental impact evaluation was examined on an independently operated microgrid. For the evaluation of environmental impact, we measured the amount of CO 2 exhausted from the micro grid when the installation capacity of photovoltaic and of battery was changed. The amount of CO 2 emission was compared by equipment with different amount of the introduction. The capacity of battery installation that achieves the least amount of the CO 2 emission was examined.

AB - In this paper, the environmental impact evaluation was examined on an independently operated microgrid. For the evaluation of environmental impact, we measured the amount of CO 2 exhausted from the micro grid when the installation capacity of photovoltaic and of battery was changed. The amount of CO 2 emission was compared by equipment with different amount of the introduction. The capacity of battery installation that achieves the least amount of the CO 2 emission was examined.

KW - Battery

KW - CO emission

KW - Component

KW - Environment inpact

KW - Microgrid

KW - Photovoltaics

UR - http://www.scopus.com/inward/record.url?scp=84869983225&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84869983225&partnerID=8YFLogxK

U2 - 10.1109/APPEEC.2009.4918633

DO - 10.1109/APPEEC.2009.4918633

M3 - Conference contribution

AN - SCOPUS:84869983225

SN - 9781424424870

BT - Asia-Pacific Power and Energy Engineering Conference, APPEEC

ER -