Rapid and sensitive detection of 17β-estradiol in environmental water using automated immunoassay system with bacterial magnetic particles

Tsuyoshi Tanaka, Hajime Takeda, Fumiko Ueki, Kimimichi Obata, Hideji Tajima, Haruko Takeyama, Yasuhiro Goda, Shigeru Fujimoto, Tadashi Matsunaga

Research output: Contribution to journalArticle

64 Citations (Scopus)

Abstract

A fully automated immunoassay of 17β-estradiol (E2) was performed using anti-E2 monoclonal antibody immobilized on bacterial magnetic particles (AntiE2-BMPs) and alkaline phosphatase-conjugated E2 (ALP-E2). E2 concentration in environmental water samples was evaluated by decrease in luminescence based on competitive reaction. A linear correlation between the luminescence intensity and E2 concentration was obtained between 0.5 and 5ppb. The minimum detectable concentration of E2 was 20ppt. All measurement steps were done within 0.5h. The analysis of environmental water samples by a commercially available ELISA kit and the BMP-based immunoassay gave good correlation plots with a correlation efficient of 0.992. These results suggest that the fully automated system using the BMP-based immunoassay has some advantages in the high rapidity and sensitivity of the measurement. This system will enable us to determine low E2 concentrations without sample condensation.

Original languageEnglish
Pages (from-to)153-159
Number of pages7
JournalJournal of Biotechnology
Volume108
Issue number2
DOIs
Publication statusPublished - 2004 Mar 4
Externally publishedYes

Fingerprint

Immunoassay
Luminescence
Estradiol
Monoclonal antibodies
Water
Phosphatases
Alkaline Phosphatase
Condensation
Monoclonal Antibodies
Enzyme-Linked Immunosorbent Assay

Keywords

  • 17β-Estradiol (E2)
  • Anti-E2 monoclonal antibody
  • Bacterial magnetic particles (BMPs)
  • Fully automated immunoassay system

ASJC Scopus subject areas

  • Biotechnology

Cite this

Rapid and sensitive detection of 17β-estradiol in environmental water using automated immunoassay system with bacterial magnetic particles. / Tanaka, Tsuyoshi; Takeda, Hajime; Ueki, Fumiko; Obata, Kimimichi; Tajima, Hideji; Takeyama, Haruko; Goda, Yasuhiro; Fujimoto, Shigeru; Matsunaga, Tadashi.

In: Journal of Biotechnology, Vol. 108, No. 2, 04.03.2004, p. 153-159.

Research output: Contribution to journalArticle

Tanaka, Tsuyoshi ; Takeda, Hajime ; Ueki, Fumiko ; Obata, Kimimichi ; Tajima, Hideji ; Takeyama, Haruko ; Goda, Yasuhiro ; Fujimoto, Shigeru ; Matsunaga, Tadashi. / Rapid and sensitive detection of 17β-estradiol in environmental water using automated immunoassay system with bacterial magnetic particles. In: Journal of Biotechnology. 2004 ; Vol. 108, No. 2. pp. 153-159.
@article{9e40fedddf534a7b99cdc8d86858c2e0,
title = "Rapid and sensitive detection of 17β-estradiol in environmental water using automated immunoassay system with bacterial magnetic particles",
abstract = "A fully automated immunoassay of 17β-estradiol (E2) was performed using anti-E2 monoclonal antibody immobilized on bacterial magnetic particles (AntiE2-BMPs) and alkaline phosphatase-conjugated E2 (ALP-E2). E2 concentration in environmental water samples was evaluated by decrease in luminescence based on competitive reaction. A linear correlation between the luminescence intensity and E2 concentration was obtained between 0.5 and 5ppb. The minimum detectable concentration of E2 was 20ppt. All measurement steps were done within 0.5h. The analysis of environmental water samples by a commercially available ELISA kit and the BMP-based immunoassay gave good correlation plots with a correlation efficient of 0.992. These results suggest that the fully automated system using the BMP-based immunoassay has some advantages in the high rapidity and sensitivity of the measurement. This system will enable us to determine low E2 concentrations without sample condensation.",
keywords = "17β-Estradiol (E2), Anti-E2 monoclonal antibody, Bacterial magnetic particles (BMPs), Fully automated immunoassay system",
author = "Tsuyoshi Tanaka and Hajime Takeda and Fumiko Ueki and Kimimichi Obata and Hideji Tajima and Haruko Takeyama and Yasuhiro Goda and Shigeru Fujimoto and Tadashi Matsunaga",
year = "2004",
month = "3",
day = "4",
doi = "10.1016/j.jbiotec.2003.11.010",
language = "English",
volume = "108",
pages = "153--159",
journal = "Journal of Biotechnology",
issn = "0168-1656",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Rapid and sensitive detection of 17β-estradiol in environmental water using automated immunoassay system with bacterial magnetic particles

AU - Tanaka, Tsuyoshi

AU - Takeda, Hajime

AU - Ueki, Fumiko

AU - Obata, Kimimichi

AU - Tajima, Hideji

AU - Takeyama, Haruko

AU - Goda, Yasuhiro

AU - Fujimoto, Shigeru

AU - Matsunaga, Tadashi

PY - 2004/3/4

Y1 - 2004/3/4

N2 - A fully automated immunoassay of 17β-estradiol (E2) was performed using anti-E2 monoclonal antibody immobilized on bacterial magnetic particles (AntiE2-BMPs) and alkaline phosphatase-conjugated E2 (ALP-E2). E2 concentration in environmental water samples was evaluated by decrease in luminescence based on competitive reaction. A linear correlation between the luminescence intensity and E2 concentration was obtained between 0.5 and 5ppb. The minimum detectable concentration of E2 was 20ppt. All measurement steps were done within 0.5h. The analysis of environmental water samples by a commercially available ELISA kit and the BMP-based immunoassay gave good correlation plots with a correlation efficient of 0.992. These results suggest that the fully automated system using the BMP-based immunoassay has some advantages in the high rapidity and sensitivity of the measurement. This system will enable us to determine low E2 concentrations without sample condensation.

AB - A fully automated immunoassay of 17β-estradiol (E2) was performed using anti-E2 monoclonal antibody immobilized on bacterial magnetic particles (AntiE2-BMPs) and alkaline phosphatase-conjugated E2 (ALP-E2). E2 concentration in environmental water samples was evaluated by decrease in luminescence based on competitive reaction. A linear correlation between the luminescence intensity and E2 concentration was obtained between 0.5 and 5ppb. The minimum detectable concentration of E2 was 20ppt. All measurement steps were done within 0.5h. The analysis of environmental water samples by a commercially available ELISA kit and the BMP-based immunoassay gave good correlation plots with a correlation efficient of 0.992. These results suggest that the fully automated system using the BMP-based immunoassay has some advantages in the high rapidity and sensitivity of the measurement. This system will enable us to determine low E2 concentrations without sample condensation.

KW - 17β-Estradiol (E2)

KW - Anti-E2 monoclonal antibody

KW - Bacterial magnetic particles (BMPs)

KW - Fully automated immunoassay system

UR - http://www.scopus.com/inward/record.url?scp=0842281273&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0842281273&partnerID=8YFLogxK

U2 - 10.1016/j.jbiotec.2003.11.010

DO - 10.1016/j.jbiotec.2003.11.010

M3 - Article

VL - 108

SP - 153

EP - 159

JO - Journal of Biotechnology

JF - Journal of Biotechnology

SN - 0168-1656

IS - 2

ER -