Robotic surgery in neurosurgical field

Hiroshi Iseki, Yoshihiro Muragaki, Ryoichi Nakamura, Kouji Nishizawa, Shigeru Omori, Motohiro Hayashi, Tomokatsu Hori, Kintomo Takakura

Research output: Contribution to journalArticle

Abstract

Computer-aided surgery commenced in the late 1980s when computer was clinically used for diagnosis and surgical planning. Since then the computer has been used in a surgical navigation system. In the early 1990s a robotic surgery using intelligent manipulator as surgeon's new hands took place. Nowadays intraoperative diagnostic imaging as surgeon's new eyes has become ubiquitous Diagnosis, surgical planning, and navigation are required to be real-timely performed intraoperatively. The time has really come to concurrently diagnose and treat, in which technology visualizing intraoperative medical information and minimally invasive surgery are fused. For that it is necessary to develop a system that real-timely updates information for decision making, and at the same time to present the timely, optimum treatment to be done according to the results of instant evaluation of ongoing treatment. To realize and support above system it is essential to combine a sensor which can precisely distinguishes a focal area from a normal tissue intraoperatively, and a manipulator which participates the treatment. In addition, the manipulator should be accurately controlled using a computer (computer-aided manipulation) according to the surgical plan made by a method aided by a computer (computer-aided design) based on intraoperatively acquired information. It is about to change quality of life to quality of treatment.

Original languageEnglish
Pages (from-to)763-766
Number of pages4
JournalNippon Geka Gakkai zasshi
Volume105
Issue number12
Publication statusPublished - 2004
Externally publishedYes

Fingerprint

Robotics
Quality of Life
Computer-Assisted Surgery
Computer-Aided Design
Minimally Invasive Surgical Procedures
Diagnostic Imaging
Therapeutics
Decision Making
Hand
Technology
Surgeons

Cite this

Iseki, H., Muragaki, Y., Nakamura, R., Nishizawa, K., Omori, S., Hayashi, M., ... Takakura, K. (2004). Robotic surgery in neurosurgical field. Nippon Geka Gakkai zasshi, 105(12), 763-766.

Robotic surgery in neurosurgical field. / Iseki, Hiroshi; Muragaki, Yoshihiro; Nakamura, Ryoichi; Nishizawa, Kouji; Omori, Shigeru; Hayashi, Motohiro; Hori, Tomokatsu; Takakura, Kintomo.

In: Nippon Geka Gakkai zasshi, Vol. 105, No. 12, 2004, p. 763-766.

Research output: Contribution to journalArticle

Iseki, H, Muragaki, Y, Nakamura, R, Nishizawa, K, Omori, S, Hayashi, M, Hori, T & Takakura, K 2004, 'Robotic surgery in neurosurgical field', Nippon Geka Gakkai zasshi, vol. 105, no. 12, pp. 763-766.
Iseki H, Muragaki Y, Nakamura R, Nishizawa K, Omori S, Hayashi M et al. Robotic surgery in neurosurgical field. Nippon Geka Gakkai zasshi. 2004;105(12):763-766.
Iseki, Hiroshi ; Muragaki, Yoshihiro ; Nakamura, Ryoichi ; Nishizawa, Kouji ; Omori, Shigeru ; Hayashi, Motohiro ; Hori, Tomokatsu ; Takakura, Kintomo. / Robotic surgery in neurosurgical field. In: Nippon Geka Gakkai zasshi. 2004 ; Vol. 105, No. 12. pp. 763-766.
@article{42d42480cb704ec295a5b3d6e9de1f84,
title = "Robotic surgery in neurosurgical field",
abstract = "Computer-aided surgery commenced in the late 1980s when computer was clinically used for diagnosis and surgical planning. Since then the computer has been used in a surgical navigation system. In the early 1990s a robotic surgery using intelligent manipulator as surgeon's new hands took place. Nowadays intraoperative diagnostic imaging as surgeon's new eyes has become ubiquitous Diagnosis, surgical planning, and navigation are required to be real-timely performed intraoperatively. The time has really come to concurrently diagnose and treat, in which technology visualizing intraoperative medical information and minimally invasive surgery are fused. For that it is necessary to develop a system that real-timely updates information for decision making, and at the same time to present the timely, optimum treatment to be done according to the results of instant evaluation of ongoing treatment. To realize and support above system it is essential to combine a sensor which can precisely distinguishes a focal area from a normal tissue intraoperatively, and a manipulator which participates the treatment. In addition, the manipulator should be accurately controlled using a computer (computer-aided manipulation) according to the surgical plan made by a method aided by a computer (computer-aided design) based on intraoperatively acquired information. It is about to change quality of life to quality of treatment.",
author = "Hiroshi Iseki and Yoshihiro Muragaki and Ryoichi Nakamura and Kouji Nishizawa and Shigeru Omori and Motohiro Hayashi and Tomokatsu Hori and Kintomo Takakura",
year = "2004",
language = "English",
volume = "105",
pages = "763--766",
journal = "Nihon Geka Gakkai zasshi",
issn = "0301-4894",
publisher = "Nihon Geka Gakkai",
number = "12",

}

TY - JOUR

T1 - Robotic surgery in neurosurgical field

AU - Iseki, Hiroshi

AU - Muragaki, Yoshihiro

AU - Nakamura, Ryoichi

AU - Nishizawa, Kouji

AU - Omori, Shigeru

AU - Hayashi, Motohiro

AU - Hori, Tomokatsu

AU - Takakura, Kintomo

PY - 2004

Y1 - 2004

N2 - Computer-aided surgery commenced in the late 1980s when computer was clinically used for diagnosis and surgical planning. Since then the computer has been used in a surgical navigation system. In the early 1990s a robotic surgery using intelligent manipulator as surgeon's new hands took place. Nowadays intraoperative diagnostic imaging as surgeon's new eyes has become ubiquitous Diagnosis, surgical planning, and navigation are required to be real-timely performed intraoperatively. The time has really come to concurrently diagnose and treat, in which technology visualizing intraoperative medical information and minimally invasive surgery are fused. For that it is necessary to develop a system that real-timely updates information for decision making, and at the same time to present the timely, optimum treatment to be done according to the results of instant evaluation of ongoing treatment. To realize and support above system it is essential to combine a sensor which can precisely distinguishes a focal area from a normal tissue intraoperatively, and a manipulator which participates the treatment. In addition, the manipulator should be accurately controlled using a computer (computer-aided manipulation) according to the surgical plan made by a method aided by a computer (computer-aided design) based on intraoperatively acquired information. It is about to change quality of life to quality of treatment.

AB - Computer-aided surgery commenced in the late 1980s when computer was clinically used for diagnosis and surgical planning. Since then the computer has been used in a surgical navigation system. In the early 1990s a robotic surgery using intelligent manipulator as surgeon's new hands took place. Nowadays intraoperative diagnostic imaging as surgeon's new eyes has become ubiquitous Diagnosis, surgical planning, and navigation are required to be real-timely performed intraoperatively. The time has really come to concurrently diagnose and treat, in which technology visualizing intraoperative medical information and minimally invasive surgery are fused. For that it is necessary to develop a system that real-timely updates information for decision making, and at the same time to present the timely, optimum treatment to be done according to the results of instant evaluation of ongoing treatment. To realize and support above system it is essential to combine a sensor which can precisely distinguishes a focal area from a normal tissue intraoperatively, and a manipulator which participates the treatment. In addition, the manipulator should be accurately controlled using a computer (computer-aided manipulation) according to the surgical plan made by a method aided by a computer (computer-aided design) based on intraoperatively acquired information. It is about to change quality of life to quality of treatment.

UR - http://www.scopus.com/inward/record.url?scp=14144249173&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=14144249173&partnerID=8YFLogxK

M3 - Article

C2 - 15651478

AN - SCOPUS:14144249173

VL - 105

SP - 763

EP - 766

JO - Nihon Geka Gakkai zasshi

JF - Nihon Geka Gakkai zasshi

SN - 0301-4894

IS - 12

ER -