    In this study, a simple method for quantitative PCR (qPCR) with a microfluidic device is proposed and evaluated. PCR was performed in a flow-through manner with a SYBR green containing PCR mixture. During and after the PCR operations, the fluorescence intensity was continuously monitored to obtain forward and inversed amplification curves. As a result of evaluation, quite linear calibration curve was obtained both with the forward and the inversed amplification curve.

    Original languageEnglish
    Title of host publication12th International Conference on Miniaturized Systems for Chemistry and Life Sciences - The Proceedings of MicroTAS 2008 Conference
    PublisherChemical and Biological Microsystems Society
    Pages1743-1745
    Number of pages3
    Publication statusPublished - 2008
    Event12th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2008 - San Diego, CA
    Duration: 2008 Oct 122008 Oct 16

    Other

    Other12th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2008
    CitySan Diego, CA
    Period08/10/1208/10/16

    Fingerprint

    Amplification
    Microfluidics
    Fluorescence
    Calibration

    Keywords

    • Flow-through polymerase chain reaction
    • Polydimethylsiloxane
    • Quantitative polymerase chain reaction

    ASJC Scopus subject areas

    • Chemical Engineering (miscellaneous)
    • Bioengineering

    Cite this

    Fukuba, T., Hiraga, M., Takamatsu, A., Provin, C., Yamamoto, T., & Fujii, T. (2008). Simple method for quantitative PCR using flow-through PCR device. In 12th International Conference on Miniaturized Systems for Chemistry and Life Sciences - The Proceedings of MicroTAS 2008 Conference (pp. 1743-1745). Chemical and Biological Microsystems Society.

    Simple method for quantitative PCR using flow-through PCR device. / Fukuba, T.; Hiraga, M.; Takamatsu, Atsuko; Provin, C.; Yamamoto, T.; Fujii, T.

    12th International Conference on Miniaturized Systems for Chemistry and Life Sciences - The Proceedings of MicroTAS 2008 Conference. Chemical and Biological Microsystems Society, 2008. p. 1743-1745.

    Research output: Chapter in Book/Report/Conference proceedingConference contribution

    Fukuba, T, Hiraga, M, Takamatsu, A, Provin, C, Yamamoto, T & Fujii, T 2008, Simple method for quantitative PCR using flow-through PCR device. in 12th International Conference on Miniaturized Systems for Chemistry and Life Sciences - The Proceedings of MicroTAS 2008 Conference. Chemical and Biological Microsystems Society, pp. 1743-1745, 12th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2008, San Diego, CA, 08/10/12.
    Fukuba T, Hiraga M, Takamatsu A, Provin C, Yamamoto T, Fujii T. Simple method for quantitative PCR using flow-through PCR device. In 12th International Conference on Miniaturized Systems for Chemistry and Life Sciences - The Proceedings of MicroTAS 2008 Conference. Chemical and Biological Microsystems Society. 2008. p. 1743-1745
    Fukuba, T. ; Hiraga, M. ; Takamatsu, Atsuko ; Provin, C. ; Yamamoto, T. ; Fujii, T. / Simple method for quantitative PCR using flow-through PCR device. 12th International Conference on Miniaturized Systems for Chemistry and Life Sciences - The Proceedings of MicroTAS 2008 Conference. Chemical and Biological Microsystems Society, 2008. pp. 1743-1745
    @inproceedings{1f73909a1186478cb1dcb7253dc571aa,
    title = "Simple method for quantitative PCR using flow-through PCR device",
    abstract = "In this study, a simple method for quantitative PCR (qPCR) with a microfluidic device is proposed and evaluated. PCR was performed in a flow-through manner with a SYBR green containing PCR mixture. During and after the PCR operations, the fluorescence intensity was continuously monitored to obtain forward and inversed amplification curves. As a result of evaluation, quite linear calibration curve was obtained both with the forward and the inversed amplification curve.",
    keywords = "Flow-through polymerase chain reaction, Polydimethylsiloxane, Quantitative polymerase chain reaction",
    author = "T. Fukuba and M. Hiraga and Atsuko Takamatsu and C. Provin and T. Yamamoto and T. Fujii",
    year = "2008",
    language = "English",
    pages = "1743--1745",
    booktitle = "12th International Conference on Miniaturized Systems for Chemistry and Life Sciences - The Proceedings of MicroTAS 2008 Conference",
    publisher = "Chemical and Biological Microsystems Society",

    }

    TY - GEN

    T1 - Simple method for quantitative PCR using flow-through PCR device

    AU - Fukuba, T.

    AU - Hiraga, M.

    AU - Takamatsu, Atsuko

    AU - Provin, C.

    AU - Yamamoto, T.

    AU - Fujii, T.

    PY - 2008

    Y1 - 2008

    N2 - In this study, a simple method for quantitative PCR (qPCR) with a microfluidic device is proposed and evaluated. PCR was performed in a flow-through manner with a SYBR green containing PCR mixture. During and after the PCR operations, the fluorescence intensity was continuously monitored to obtain forward and inversed amplification curves. As a result of evaluation, quite linear calibration curve was obtained both with the forward and the inversed amplification curve.

    AB - In this study, a simple method for quantitative PCR (qPCR) with a microfluidic device is proposed and evaluated. PCR was performed in a flow-through manner with a SYBR green containing PCR mixture. During and after the PCR operations, the fluorescence intensity was continuously monitored to obtain forward and inversed amplification curves. As a result of evaluation, quite linear calibration curve was obtained both with the forward and the inversed amplification curve.

    KW - Flow-through polymerase chain reaction

    KW - Polydimethylsiloxane

    KW - Quantitative polymerase chain reaction

    UR - http://www.scopus.com/inward/record.url?scp=84902504176&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84902504176&partnerID=8YFLogxK

    M3 - Conference contribution

    SP - 1743

    EP - 1745

    BT - 12th International Conference on Miniaturized Systems for Chemistry and Life Sciences - The Proceedings of MicroTAS 2008 Conference

    PB - Chemical and Biological Microsystems Society

    ER -