The energy demand of the commercial building sector is largely for cooling and heating and will eventually result in energy and environmental crises; therefore, enhancing the performance of the cooling and heating systems used in buildings is paramount. In response to this need, focus was set on the gas engine-driven heat pump-combined system (GHPC)—consisting of a gas engine, single-stage vapour compression system, and single-effect absorption system— that saves more energy as compared to a conventional gas engine-driven heat pump. However, so far, only the performance and transient characteristics of a fabricated GHPC have been investigated. Therefore, to ascertain the characteristics of the GHPC start-up dynamics under unsteady state operations so as to achieve efficient and stable start-up operation, experiments and simulations were attempted in this study. The transient behaviour from the start-up of this combined system in cooling and heating operating modes was also scrutinized. Accordingly, it was found that simulation results agreed well with experimental data. It was concluded that there were no large delayed responses in the absorption system during start-up operation when start-up of the absorption system is considered based on the system cooling capacity response after the solution pump starts.

Original languageEnglish
Pages (from-to)1346-1357
Number of pages12
JournalEnergy and Buildings
Volume158
DOIs
Publication statusPublished - 2018 Jan 1

Fingerprint

Gas engines
Air conditioning
Pumps
Cooling
Heating
Cooling systems
Vapors
Experiments
Hot Temperature

Keywords

  • Air-conditioning
  • Combined system
  • Control
  • Start-up characteristics
  • Waste heat

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

Start-up behaviour of a combined air-conditioning system in cooling and heating operating modes. / Jeong, Jongsoo; Arnas, Arnas; Saito, Kiyoshi; Karng, Sarngwoo; Kim, Seoyoung; Kim, Kwangho.

In: Energy and Buildings, Vol. 158, 01.01.2018, p. 1346-1357.

Research output: Contribution to journalArticle

Jeong, Jongsoo ; Arnas, Arnas ; Saito, Kiyoshi ; Karng, Sarngwoo ; Kim, Seoyoung ; Kim, Kwangho. / Start-up behaviour of a combined air-conditioning system in cooling and heating operating modes. In: Energy and Buildings. 2018 ; Vol. 158. pp. 1346-1357.
@article{ae72e9e80c8f40f3a5fc2c0c2f03be43,
title = "Start-up behaviour of a combined air-conditioning system in cooling and heating operating modes",
abstract = "The energy demand of the commercial building sector is largely for cooling and heating and will eventually result in energy and environmental crises; therefore, enhancing the performance of the cooling and heating systems used in buildings is paramount. In response to this need, focus was set on the gas engine-driven heat pump-combined system (GHPC)—consisting of a gas engine, single-stage vapour compression system, and single-effect absorption system— that saves more energy as compared to a conventional gas engine-driven heat pump. However, so far, only the performance and transient characteristics of a fabricated GHPC have been investigated. Therefore, to ascertain the characteristics of the GHPC start-up dynamics under unsteady state operations so as to achieve efficient and stable start-up operation, experiments and simulations were attempted in this study. The transient behaviour from the start-up of this combined system in cooling and heating operating modes was also scrutinized. Accordingly, it was found that simulation results agreed well with experimental data. It was concluded that there were no large delayed responses in the absorption system during start-up operation when start-up of the absorption system is considered based on the system cooling capacity response after the solution pump starts.",
keywords = "Air-conditioning, Combined system, Control, Start-up characteristics, Waste heat",
author = "Jongsoo Jeong and Arnas Arnas and Kiyoshi Saito and Sarngwoo Karng and Seoyoung Kim and Kwangho Kim",
year = "2018",
month = "1",
day = "1",
doi = "10.1016/j.enbuild.2017.11.024",
language = "English",
volume = "158",
pages = "1346--1357",
journal = "Energy and Buildings",
issn = "0378-7788",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Start-up behaviour of a combined air-conditioning system in cooling and heating operating modes

AU - Jeong, Jongsoo

AU - Arnas, Arnas

AU - Saito, Kiyoshi

AU - Karng, Sarngwoo

AU - Kim, Seoyoung

AU - Kim, Kwangho

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The energy demand of the commercial building sector is largely for cooling and heating and will eventually result in energy and environmental crises; therefore, enhancing the performance of the cooling and heating systems used in buildings is paramount. In response to this need, focus was set on the gas engine-driven heat pump-combined system (GHPC)—consisting of a gas engine, single-stage vapour compression system, and single-effect absorption system— that saves more energy as compared to a conventional gas engine-driven heat pump. However, so far, only the performance and transient characteristics of a fabricated GHPC have been investigated. Therefore, to ascertain the characteristics of the GHPC start-up dynamics under unsteady state operations so as to achieve efficient and stable start-up operation, experiments and simulations were attempted in this study. The transient behaviour from the start-up of this combined system in cooling and heating operating modes was also scrutinized. Accordingly, it was found that simulation results agreed well with experimental data. It was concluded that there were no large delayed responses in the absorption system during start-up operation when start-up of the absorption system is considered based on the system cooling capacity response after the solution pump starts.

AB - The energy demand of the commercial building sector is largely for cooling and heating and will eventually result in energy and environmental crises; therefore, enhancing the performance of the cooling and heating systems used in buildings is paramount. In response to this need, focus was set on the gas engine-driven heat pump-combined system (GHPC)—consisting of a gas engine, single-stage vapour compression system, and single-effect absorption system— that saves more energy as compared to a conventional gas engine-driven heat pump. However, so far, only the performance and transient characteristics of a fabricated GHPC have been investigated. Therefore, to ascertain the characteristics of the GHPC start-up dynamics under unsteady state operations so as to achieve efficient and stable start-up operation, experiments and simulations were attempted in this study. The transient behaviour from the start-up of this combined system in cooling and heating operating modes was also scrutinized. Accordingly, it was found that simulation results agreed well with experimental data. It was concluded that there were no large delayed responses in the absorption system during start-up operation when start-up of the absorption system is considered based on the system cooling capacity response after the solution pump starts.

KW - Air-conditioning

KW - Combined system

KW - Control

KW - Start-up characteristics

KW - Waste heat

UR - http://www.scopus.com/inward/record.url?scp=85034860766&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85034860766&partnerID=8YFLogxK

U2 - 10.1016/j.enbuild.2017.11.024

DO - 10.1016/j.enbuild.2017.11.024

M3 - Article

AN - SCOPUS:85034860766

VL - 158

SP - 1346

EP - 1357

JO - Energy and Buildings

JF - Energy and Buildings

SN - 0378-7788

ER -