System improvements for exhaled breath measurement system

S. Kanou, S. Iitsuka, T. Nagaoka, N. Kobayashi, M. Kurahashi, S. Takeda, T. Aoki, C. Tsuji, T. Urano, T. Abe, K. Magatani

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

As many as 200 kinds of volatile organic compounds (VOCs) are included in human exhaled breath. Many papers using VOCs as a biomarker of respiratory diseases have been reported. However, it is very difficult to measure very low concentration of VOCs in exhaled breath with high precision. Moreover, it is also difficult to distinguish VOCs in exhaled breath and VOCs in atmosphere. Therefore, measurement of VOCs is rarely used in a clinical field because complicated and large-sized system is required for measure VOCs in exhaled breath. We are developing exhaled breath measurement system which overcame these problems. Our system analyzes exhaled breath discharged from living body by inhaling atmosphere from which VOCs were removed. In this paper, results of system improvements are reported. At first, we adopted a cold trap method with dry ice as a method of purifying atmosphere (method A). Method A needs complicated device and long processing time. Next, we changed the method into solid absorbent from method A (method B). We verified purity of purified air. Concentration of 10 kinds of VOCs contained in both exhaled breath and atmosphere were measured. Selected VOCs are as follows: benzene, cyclohexane, ethylbenzene, heptanes, hexane, isoprene, nonane, octane, toluene and xylene. Atmosphere was purified by the method A and B. Concentrations of VOCs contained in the purified air were measured by gas chromatography. As a result of measurement, almost VOCs were not detected in the purified air made by both methods. Furthermore, time to make purified air was reduced from 70 minutes to 10 minutes. Simplification of the system and shorter processing time than method A were realized by method B while keeping purity.

Original languageEnglish
Title of host publicationIFMBE Proceedings
PublisherSpringer Verlag
Pages828-830
Number of pages3
Volume43
ISBN (Print)9783319029122
DOIs
Publication statusPublished - 2014
Event15th International Conference on Biomedical Engineering, ICBME 2013 - Singapore, Singapore
Duration: 2013 Dec 42013 Dec 7

Other

Other15th International Conference on Biomedical Engineering, ICBME 2013
CountrySingapore
CitySingapore
Period13/12/413/12/7

Fingerprint

Volatile Organic Compounds
Volatile organic compounds
Air
Dry Ice
Heptanes
Xylenes
Pulmonary diseases
Isoprene
Ethylbenzene
Toluene
Hexanes
Heptane
Biomarkers
Xylene
Cyclohexane
Processing
Benzene
Hexane
Gas chromatography
Ice

Keywords

  • Cold-trap
  • Exhaled breath
  • Respiratory diseases
  • Volatile organic compound

ASJC Scopus subject areas

  • Biomedical Engineering
  • Bioengineering

Cite this

Kanou, S., Iitsuka, S., Nagaoka, T., Kobayashi, N., Kurahashi, M., Takeda, S., ... Magatani, K. (2014). System improvements for exhaled breath measurement system. In IFMBE Proceedings (Vol. 43, pp. 828-830). Springer Verlag. https://doi.org/10.1007/978-3-319-02913-9_213

System improvements for exhaled breath measurement system. / Kanou, S.; Iitsuka, S.; Nagaoka, T.; Kobayashi, N.; Kurahashi, M.; Takeda, S.; Aoki, T.; Tsuji, C.; Urano, T.; Abe, T.; Magatani, K.

IFMBE Proceedings. Vol. 43 Springer Verlag, 2014. p. 828-830.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kanou, S, Iitsuka, S, Nagaoka, T, Kobayashi, N, Kurahashi, M, Takeda, S, Aoki, T, Tsuji, C, Urano, T, Abe, T & Magatani, K 2014, System improvements for exhaled breath measurement system. in IFMBE Proceedings. vol. 43, Springer Verlag, pp. 828-830, 15th International Conference on Biomedical Engineering, ICBME 2013, Singapore, Singapore, 13/12/4. https://doi.org/10.1007/978-3-319-02913-9_213
Kanou S, Iitsuka S, Nagaoka T, Kobayashi N, Kurahashi M, Takeda S et al. System improvements for exhaled breath measurement system. In IFMBE Proceedings. Vol. 43. Springer Verlag. 2014. p. 828-830 https://doi.org/10.1007/978-3-319-02913-9_213
Kanou, S. ; Iitsuka, S. ; Nagaoka, T. ; Kobayashi, N. ; Kurahashi, M. ; Takeda, S. ; Aoki, T. ; Tsuji, C. ; Urano, T. ; Abe, T. ; Magatani, K. / System improvements for exhaled breath measurement system. IFMBE Proceedings. Vol. 43 Springer Verlag, 2014. pp. 828-830
@inproceedings{e2d097b8daf64a1ab75cc76f95203718,
title = "System improvements for exhaled breath measurement system",
abstract = "As many as 200 kinds of volatile organic compounds (VOCs) are included in human exhaled breath. Many papers using VOCs as a biomarker of respiratory diseases have been reported. However, it is very difficult to measure very low concentration of VOCs in exhaled breath with high precision. Moreover, it is also difficult to distinguish VOCs in exhaled breath and VOCs in atmosphere. Therefore, measurement of VOCs is rarely used in a clinical field because complicated and large-sized system is required for measure VOCs in exhaled breath. We are developing exhaled breath measurement system which overcame these problems. Our system analyzes exhaled breath discharged from living body by inhaling atmosphere from which VOCs were removed. In this paper, results of system improvements are reported. At first, we adopted a cold trap method with dry ice as a method of purifying atmosphere (method A). Method A needs complicated device and long processing time. Next, we changed the method into solid absorbent from method A (method B). We verified purity of purified air. Concentration of 10 kinds of VOCs contained in both exhaled breath and atmosphere were measured. Selected VOCs are as follows: benzene, cyclohexane, ethylbenzene, heptanes, hexane, isoprene, nonane, octane, toluene and xylene. Atmosphere was purified by the method A and B. Concentrations of VOCs contained in the purified air were measured by gas chromatography. As a result of measurement, almost VOCs were not detected in the purified air made by both methods. Furthermore, time to make purified air was reduced from 70 minutes to 10 minutes. Simplification of the system and shorter processing time than method A were realized by method B while keeping purity.",
keywords = "Cold-trap, Exhaled breath, Respiratory diseases, Volatile organic compound",
author = "S. Kanou and S. Iitsuka and T. Nagaoka and N. Kobayashi and M. Kurahashi and S. Takeda and T. Aoki and C. Tsuji and T. Urano and T. Abe and K. Magatani",
year = "2014",
doi = "10.1007/978-3-319-02913-9_213",
language = "English",
isbn = "9783319029122",
volume = "43",
pages = "828--830",
booktitle = "IFMBE Proceedings",
publisher = "Springer Verlag",

}

TY - GEN

T1 - System improvements for exhaled breath measurement system

AU - Kanou, S.

AU - Iitsuka, S.

AU - Nagaoka, T.

AU - Kobayashi, N.

AU - Kurahashi, M.

AU - Takeda, S.

AU - Aoki, T.

AU - Tsuji, C.

AU - Urano, T.

AU - Abe, T.

AU - Magatani, K.

PY - 2014

Y1 - 2014

N2 - As many as 200 kinds of volatile organic compounds (VOCs) are included in human exhaled breath. Many papers using VOCs as a biomarker of respiratory diseases have been reported. However, it is very difficult to measure very low concentration of VOCs in exhaled breath with high precision. Moreover, it is also difficult to distinguish VOCs in exhaled breath and VOCs in atmosphere. Therefore, measurement of VOCs is rarely used in a clinical field because complicated and large-sized system is required for measure VOCs in exhaled breath. We are developing exhaled breath measurement system which overcame these problems. Our system analyzes exhaled breath discharged from living body by inhaling atmosphere from which VOCs were removed. In this paper, results of system improvements are reported. At first, we adopted a cold trap method with dry ice as a method of purifying atmosphere (method A). Method A needs complicated device and long processing time. Next, we changed the method into solid absorbent from method A (method B). We verified purity of purified air. Concentration of 10 kinds of VOCs contained in both exhaled breath and atmosphere were measured. Selected VOCs are as follows: benzene, cyclohexane, ethylbenzene, heptanes, hexane, isoprene, nonane, octane, toluene and xylene. Atmosphere was purified by the method A and B. Concentrations of VOCs contained in the purified air were measured by gas chromatography. As a result of measurement, almost VOCs were not detected in the purified air made by both methods. Furthermore, time to make purified air was reduced from 70 minutes to 10 minutes. Simplification of the system and shorter processing time than method A were realized by method B while keeping purity.

AB - As many as 200 kinds of volatile organic compounds (VOCs) are included in human exhaled breath. Many papers using VOCs as a biomarker of respiratory diseases have been reported. However, it is very difficult to measure very low concentration of VOCs in exhaled breath with high precision. Moreover, it is also difficult to distinguish VOCs in exhaled breath and VOCs in atmosphere. Therefore, measurement of VOCs is rarely used in a clinical field because complicated and large-sized system is required for measure VOCs in exhaled breath. We are developing exhaled breath measurement system which overcame these problems. Our system analyzes exhaled breath discharged from living body by inhaling atmosphere from which VOCs were removed. In this paper, results of system improvements are reported. At first, we adopted a cold trap method with dry ice as a method of purifying atmosphere (method A). Method A needs complicated device and long processing time. Next, we changed the method into solid absorbent from method A (method B). We verified purity of purified air. Concentration of 10 kinds of VOCs contained in both exhaled breath and atmosphere were measured. Selected VOCs are as follows: benzene, cyclohexane, ethylbenzene, heptanes, hexane, isoprene, nonane, octane, toluene and xylene. Atmosphere was purified by the method A and B. Concentrations of VOCs contained in the purified air were measured by gas chromatography. As a result of measurement, almost VOCs were not detected in the purified air made by both methods. Furthermore, time to make purified air was reduced from 70 minutes to 10 minutes. Simplification of the system and shorter processing time than method A were realized by method B while keeping purity.

KW - Cold-trap

KW - Exhaled breath

KW - Respiratory diseases

KW - Volatile organic compound

UR - http://www.scopus.com/inward/record.url?scp=84928257006&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84928257006&partnerID=8YFLogxK

U2 - 10.1007/978-3-319-02913-9_213

DO - 10.1007/978-3-319-02913-9_213

M3 - Conference contribution

AN - SCOPUS:84928257006

SN - 9783319029122

VL - 43

SP - 828

EP - 830

BT - IFMBE Proceedings

PB - Springer Verlag

ER -